Transmission black and white densitometer for calibrating the blackness value of domestic industrial film

NegotiableUpdate on 01/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The transmission black and white densitometer $r $n used for calibrating the blackness value of domestic industrial film can determine the penetration of radiation by measuring the density of the film, thereby evaluating the internal defects (such as pores, cracks) and their severity of the material. The device measures density range from 0 to 5.0D and is equipped with a large capacity Li ion battery. It is charged with an 8.4V adapter and can work continuously for more than 24 hours when fully charged.
Product Details

1KODIN H600APortable black and white transmission densitometerEquipped with photoelectric detection sensorsIt can measure both density values and density differencesThe use of AC modulated light sources, synchronous reception technology, and microcomputer control and data processing methods have improved the ability to resist light and electrical interference and temperature stability; Using nonlinear fitting techniques to improve instrument measurement accuracy; increaseLED viewing platform, convenient for users to accurately locate calibration points and measurement points; At the same time, a metal casing is used to effectively shield external electromagnetic interference and ensure the stability of the instrument.

3instrumentStrict debugging and inspection have been carried out before leaving the factory. User startup preheatingAfter 5 minutes, simply press the zero calibration button to proceed with the formal measurement.

4instrumentmeasurable5.0Transmittance density within D, for values greater than5.0D also has reference value.Yes, that's rightPressure vessels, ship hulls, chemicals, bridges, hospitals, etcAn instrument for quality analysis of X-ray films.

5The overall power consumption of the machine shall not exceed4W, The overall weight of the machine shall not exceed 15Kg, More energy-efficient and portable;

6instrumentOperation steps for measuring density difference: zero pointMeasure directly after calibrationReference sampleAfter the sample reading stabilizes, release the measuring arm and press the zero calibration button until it displays as'0.00'; Then place the sample to be compared in the measurement area, press the measuring arm, and the density difference between the two samples will be displayed;

7instrumentEquipped with user calibration functionBy using professional calibration software and density sheets, it is easy to calibrate this density meter

8Turn on the deviceStable operation can be achieved in 2 minutes, allowing for faster entry into a stable working state;

Transmission black and white densitometer for calibrating the blackness value of domestic industrial filmProduct performance

Measurement density range:0~5.0D

Measurement area:2mm (aperture diameter)

Repetitive error:±0.01D

measurement error:(0.00D~3.00D)±0.02D

(3.00D~4.50D)±0.03D

(4.50D~5.00D)±0.04D

Display mode: Three digit broken code LCD screen

Power supply mode: dedicated adapter,8.4v 1000mA

Battery capacity:2200mAh

power waste:≤4w

Usage environment:0~40 ℃, relative humidity ≤ 85%

Overall dimensions:210mm*100mm*110mm

Weight: Approximately1.5kg

working hours:≥ 24 hours (turn off the viewing light)

Viewing time:≥ 4h (turn on the viewing light)

Transmission black and white densitometer for calibrating the blackness value of domestic industrial filmConfiguration sheet:

1. Host: one unit;

2. Density sheet (including report): one set;

3. Charger: one;

4. Fuses: two;

5. Suitcase: one;