Touch screen controlled plastic thermal deformation Vicat softening point temperature tester

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The ZB-909 touch screen controlled plastic thermal deformation Vicat softening point temperature tester is suitable for testing the Vicat softening point temperature and thermal deformation temperature of plastics and polymer materials. As an indicator for controlling quality and identifying the thermal performance of new varieties, the deformation is measured by a digital dial gauge, the temperature controller sets the heating rate, and the sample holder automatically rises and falls. Three samples can be tested at once.

Product Details

Machine model:ZB-909typeTouch screen controlled plastic thermal deformation Vicat softening point temperature tester

One Product Usage

ZB-909typeTouch screen controlled plastic thermal deformation Vicat softening point temperature testerSuitable for the determination of thermal deformation and Vicat softening point temperature of non-metallic materials and polymer materials,

Designed and manufactured according to international and national standards, this testing machine is widely used in the chemical industry, scientific research institutions, universities, and quality inspection departments,

It can also serve as an ideal testing equipment for professional production units.

II Applicable standards:

conform toGB/T 1633Test method for softening point (Vicat) of thermoplastic materialsGB/T 1634Test Method for Thermal Deformation Temperature of Plastic under Bending Load

GB8802andISO75TheISO306requirement

III Technical Specifications:

1. Temperature control range:

Environmental temperature~300 ℃

2. Heating rate:

(12±1)℃/6min [(120±10)℃/h]

(5±0.5)℃/6min [(50±5)℃/h]

3. Temperature error:

±0.5℃

4. Deformation measurement method:

Digital Dial Indicator

5. Deformation measurement range:

12mm

6. Deformation measurement error:

±0.001mm

7. Number of sample racks:

3a

8. Heating medium:

Methyl silicone oil (to be provided by the purchaser)

9. Heating power:

3.4kW

10. Cooling method:

150℃Natural cooling above, natural cooling or water cooling below 150 ℃

11. Protection function:

Protection function with adjustable upper temperature limit (ambient temperature~300 ℃)

12. Total mass of load rod and pressure head:

68g

13. Test load:


AVika test load:

GA=10N±0.2N

GB=50N±1N

BHot deformation test load (F):

F=2×δ×b×h×h/(3×L)

In the formula, F:

The load required for the sample, in N units

δ:

Thermal deformation standard bending normal stress, unit Mpa

-Method A:

Using fiber stress of 1.80MPa

-Method B:

Using fiber stress of 0.45MPa

-Method C:

Using fiber stress of 8.00MPa

b:

The width of the sample, measured in millimeters

h:

The height of the sample, in millimeters

L:

Distance between two points, 100mm/64mm

14. Power Supply:

AC220V±10%、50Hz

15. The purchaser shall provide their own methyl silicone oil:

Flash point of 300 degrees, viscosity of 200 cubic meters, 20 liters

1 set of weights:


serial number

1

2

3

4

5

6

7

8

9

weight of the weight

2g

5g

10g

20g

50g

100g

200g

912g

1000g

number of pieces

6

3

3

6

3

3

6

3

12