Welcome Customer !

Membership

Help

Junqi Instrument Equipment (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Junqi Instrument Equipment (Shanghai) Co., Ltd

  • E-mail

  • Phone

    18017027751

  • Address

    No. 293-295 Yexie Yexiao Road, Songjiang District, Shanghai

Contact Now

TopPette manual (adjustable&fixed) pipette

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Each pipette of Dalong has undergone factory testing and calibration according to the requirements of ISO8655 before leaving the factory, and the claimed inaccuracy and precision are superior to the specified standards of ISO8655. During the use of pipettes, deviations may occur due to various reasons, and regular calibration is an important means to ensure their accuracy.
Product Details

Characteristics of single channel pipette
-Lightweight and designed to conform to ergonomics
-Digital window, making the set range clear at a glance
-Wide range of measurement, from 0.1 μ l to 10ml
-Using attachment tools allows for convenient and efficient calibration and maintenance
-Accurate liquid separation, each pipette is calibrated according to EN/ISO8655 standards
-The lower half can be sterilized under high temperature and high pressure

The multi-channel pipette also has the following innovative features
-The nozzle ejector can simultaneously eject multiple suction nozzles, which is efficient and labor-saving
-8 and 12 pipettes of various ranges are suitable for standard 96 well plates
-The liquid head can rotate 360 degrees, making it convenient for pipetting
-Each nozzle connection has an independent piston device, making maintenance and repair convenient
-Special nozzle connector design, easy to observe the sealing condition of the suction nozzle

calibration
Each pipette of Dalong has undergone factory testing and calibration in accordance with the requirements of ISO8655 before leaving the factory, and the claimed inaccuracy and precision are better than

The standard specified in ISO8655.
During the use of pipettes, deviations may occur due to various reasons, and regular calibration is an important means to ensure their accuracy.
Da LonginstrumentFree online calibration support is provided through its website. If you need calibration, please log in to www.dragon-lab.com and use our online calibration software

It can perform simple operation, accurate calculation, and timely calibration work without any cost, and avoid calibration errors caused by non professional operations.
We have listed the necessary conditions and standard procedures for calibration in the calibration guide. Please follow the steps to ensure the accurate implementation of calibration.

Ordering Information

TopPetteSingle channel manually adjustable pipette
Item Number range increment Measuring Volumeμl Allow * system error
Inaccuracy
Allow * random error
inaccuracy
% μl % μl
711111010000 0.1-2.5μl 0.05μl 2.5 2.50% 0.0625 2% 0.05
1.25 3% 0.0375 3% 0.0375
0.25 12% 0.03 6% 0.015
711111040000 0.5-10μl 0.1μl 10 1% 0.1 0.80% 0.08
5 1.50% 0.075 1.50% 0.075
1 2.50% 0.025 1.50% 0.015
711111050000 2-20μl 0.5μl 20 0.90% 0.18 0.40% 0.08
10 1.20% 0.12 1% 0.1
2 3% 0.06 2% 0.04
711111060000 5-50μl 0.5μl 50 0.60% 0.3 0.30% 0.15
25 0.90% 0.225 0.60% 0.15
5 2% 0.1 2% 0.1
711111080000 10-100μl 1μl 100 0.80% 0.8 0.15% 0.15
50 1% 0.5 0.40% 0.2
10 3% 0.3 1.50% 0.15
711111090000 20-200μl 1μl 200 0.60% 1.2 0.15% 0.3
100 0.80% 0.8 0.30% 0.3
20 3% 0.6 1% 0.2
711111110000 50-200μl 1μl 200 0.60% 1.2 0.15% 0.3
100 0.80% 0.8 0.30% 0.3
50 1% 0.5 0.40% 0.2
711111140000 100-1000μl 5μl 1000 0.60% 6 0.20% 2
500 0.70% 3.5 0.25% 1.25
100 2% 2 0.70% 0.7
711111160000 200-1000μl 5μl 1000 0.60% 6 0.20% 2
500 0.70% 3.5 0.25% 1.25
200 0.90% 1.8 0.30% 0.6
711111170000 1000-5000μl 50μl 5000 0.50% 25 0.15% 7.5
2500 0.60% 15 0.30% 7.5
1000 0.70% 7 0.30% 3
711111330000 2-10ml 0.1ml 10ml 0.60% 60 0.20% 20
5ml 1.20% 60 0.30% 15
2ml 3% 60 0.60% 12
8Dao manual adjustable pipette
Item Number range increment Measuring Volumeμl Allow * system error
Inaccuracy
Allow * random error
inaccuracy
% μl % μl
711112040000 0.5-10μl 0.1μl 10 1.50% 0.15 1.50% 0.15
5 2.50% 0.125 2.50% 0.125
1 4% 0.04 4% 0.04
711112060000 5-50μl 0.5μl 50 1% 0.5 0.50% 0.25
25 1.50% 0.375 1% 0.25
5 3% 0.15 2% 0.1
711112120000 50-300μl 5μl 300 0.70% 2.1 0.25% 0.75
150 1% 1.5 0.50% 0.75
50 1.50% 0.75 0.80% 0.4
12Dao manual adjustable pipette
Item Number range increment Measuring Volumeμl Allow * system error
Inaccuracy
Allow * random error
inaccuracy
% μl % μl
711113040000 0.5-10μl 0.1μl 10 1.50% 0.15 1.50% 0.15
5 2.50% 0.125 2.50% 0.125
1 4% 0.04 4% 0.04
711113060000 5-50μl 0.5μl 50 1% 0.5 0.50% 0.25
25 1.50% 0.375 1% 0.25
5 3% 0.15 2% 0.1
711113120000 50-300μl 5μl 300 0.70% 2.1 0.25% 0.75
150 1% 1.5 0.50% 0.75
50 1.50% 0.75 0.80% 0.4
Manually fix the pipette
Item Number range increment Measuring Volumeμl Allow * system error
Inaccuracy
Allow * random error
inaccuracy
% μl % μl
711121180000 5μl - 5μl 1.3% 0.065 1.2% 0.06
711121190000 10μl - 10μl 0.8% 0.08 0.8% 0.08
711121200000 20μl - 20μl 0.6% 0.12 0.5% 0.1
711121210000 25μl - 25μl 0.5% 0.125 0.3% 0.075
711121220000 50μl - 50μl 0.5% 0.25 0.3% 0.15
711121230000 100μl - 100μl 0.5% 0.5 0.3% 0.3
711121240000 200μl - 200μl 0.4% 0.8 0.2% 0.4
711121250000 250μl -- 250μl 0.4% 1.0 0.2% 0.5
711121260000 500μl - 500μl 0.3% 1.5 0.2% 1.0
711121270000 1000μl - 1000μl 0.3% 3.0 0.2% 2.0
711121280000 2000μl - 2000μl 0.3% 6.0 0.15% 3.0
711121290000 5000μl - 5000μl 0.3% 15 0.15% 7.5

Updated on September 2, 2020 at 10:22:41