Tokyo Physical and Chemical PPM-5512 Organic Synthesis Plant

NegotiableUpdate on 10/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Tokyo Physical and Chemical PPM-5512 Organic Synthesis Plant

Product Details





model

PPM-5512

Number of test tubes

1~ 5branch(Maximum support20branch)

Synthesis quantity

0.5~60mL(Change the reaction volume by replacing the test tube and corresponding adapter)

Mixing method

Strong magnetic stirring

Temperature regulation range

-20~160 (Independent temperature control)(50~60mL~130℃) independent temperature regulation

Temperature regulation accuracy

±0.5

stirring speed

300~2000rpm Five reaction sites are stirred independently

Temperature settingdisplay

Number settingdigital display

Mixing settingdisplay

Knob settingdigital display

Gas displacement

Introduce inert gas after vacuuming

reflow

Condensation reflux aluminum block+Water divider (optional)

Sample addition

Pipette, syringe, and dropper funnel can all be added under inert conditions

Reaction observation

Observe through the observation window of the heated aluminum block

safety function

Leakage and overcurrent protectors, temperature insurance, self diagnostic function (variable upper and lower temperature limits, sensor abnormalities) double-layer protective cover, motor overheating protection

Grinding size

Φ15/35、Φ14/23

External dimensions(mmweight

370W×331D×323H(Top)about19kg



Product Features:

Each reaction vessel has independent stirring function, and independent stirring speed and temperature conditions can be set for each reaction vessel. Each vessel can independently carry out synthesis reactions. The set values can be saved without the need to input experimental parameters.

Equipped with a two-stage temperature program function, synthesis tests can be conducted through the temperature settings of the two stages.

By changing or adding adapters, the synthesis volume can be adjusted from 0.5 to 60mL, and containers of different specifications can be freely combined.

Display aluminum block temperature, reaction system temperature, set value, stirring speed, etc. through LCD screen.

■ It has frost prevention function. When this function is activated, even if the temperature control is stopped, the temperature of the aluminum block can still be maintained at the set temperature (0-30 ℃). It can prevent aluminum blocks from frosting caused by cooling water.