Welcome Customer !

Membership

Help

Ankerui Electric Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Ankerui Electric Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 253 Yulu Road, Malu Town, Jiading District, Shanghai

Contact Now

Three phase three wire intelligent energy meter

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The DSZ1352 three-phase three wire intelligent energy meter is mainly used to measure the active and reactive energy of low-voltage networks, and can also measure operating parameters such as voltage, current, power, and demand. It has infrared communication function, making it convenient for users to monitor, collect, and manage electricity consumption. It can be flexibly installed in the distribution box to achieve sub item energy measurement, statistics, and analysis for different areas and loads.

Product Details

1 Product Introduction

DSZ1352Three phase three wire intelligent energy meterMainly used for measuring three-phase three wire active and reactive power in low-voltage networks, it can also measure operating parameters such as voltage, current, power, and demand. It has infrared communication function, which facilitates users to monitor, collect and manage electricity consumption. It can be flexibly installed in the distribution box to achieve sub item energy measurement, statistics, and analysis for different areas and loads. The product complies with national standards such as GB/T17215.321-2021 "Special Requirements for Electrical Measuring Equipment Part 21: Static Active Energy Meters (Class A, B, C, D, and E)", GB/T15284-2002 "Special Requirements for Multi Rate Energy Meters", and Q/GDW10827-2020 "Technical Specification for Three phase Intelligent Energy Meters", as well as enterprise standards of State Grid Corporation of China. The communication protocol complies with DL/T698.45-2017, DL/T645-2007 standards, and MODBUS-RTU protocol.

2 Main features

Adopting high-quality, high-precision, high-sensitivity, high stability, wide range, low-power dedicated metering chips.

The voltage sampling circuit adopts resistance voltage division method.

The current sampling circuit adopts high-quality, high-precision, high stability, and wide range transformers.

The display adopts an LCD monitor with wide viewing angle, high contrast, UV protection, and reliable performance.

Apply digital processing technology and SMT process. Firm structure, flame retardant, anti-aging and good sealing performance.

The case structure size is unified, simple, beautiful and exquisite, and easy to install.

3 Main Technical Parameters

三相三线智能电能表

4 Three phase three wire intelligent energy meterBasic functions

Basic functions

Functional Overview

electricity metering

measurementForward and backwardCombinationmeritoriousGeneral, sharp, peak, flat, valleyelectric energyThe combination of active power can be set arbitrarily according to the characteristic words of the active power combination methodmeasurementfour quadrantsCombination1Combination2no meritGeneral, sharp, peak, flat, valleyelectric energy. Combination1And combination2The reactive power metering mode can be based on reactive power combinations1Combined with reactive power2Method characteristic wordsPerform selective addition and subtraction combinations.

Quantity measurement

canrecordPositive and negative active power, reactive power in quadrants 1, 2, 3, and 4, combined reactive power demand and occurrence time of 1 and 2The demand calculation adopts the slip method. The demand cycle and slip time can be set within the range of 1 to 60 minutes.

Clock and Timing

The electric energy meter has a built-in hardware clock with temperature compensation function; Clock accuracy ≤±0.5s/dTime calibration of the electric energy meter can be achieved through RS485 and infrared communication interfaces (requires programming switch and communication password coordination)Broadcast timing (without the need for programming switches and communication passwords), but only once a day is allowed, and the timing range does not exceed 5 minutes. Energy meters with an error greater than 5 minutes can only be calibrated on site.

Time slot rate

The energy meter can support switching between four rates (peak, off peak, off peak, and off peak)haveTwo sets of time zone tables and two sets of daily time zone table schemes, as well as their respective switching times (year, month, day, hour, and minute)The automatic switching between two rate schemes can be achieved by pre-set timeEach rate period plan can set up 14 time zones throughout the year, with each time zone setting a starting date and the time period table number used. You can set 14 time periods per day, each with a starting time and usage rate.

Electricity freeze

Instantaneous freeze: After receiving the instantaneous freeze command, the meter freezes all current electricity data, time, and some important measurement data, and saves the last 3 instantaneous freeze data.

Timed Freeze: It can be set to freeze on an hourly, daily, and monthly basis, saving the last 60 timed freeze data.

Daily Freeze: The daily freeze time can be set, and the default freeze time is 00:00. It can store the daily freeze data of the last 62 days.

Agreed Freeze: Freeze the electricity and other important data at the agreed time of switching between the primary and secondary annual time zone schemes/daily time zone table schemes/rate schemes/tiered electricity pricing schemes, and store the last two switching records for each.

Measurement and monitoring

This instrument measures the total voltage, current, phase angle, apparent power, active power, reactive power, power factor, and grid frequency of phases A and C in real time, and displays the direction of power.

communication

RS485, infrared communication

5. Outline and Installation Dimensional Diagram

External dimensions (mm): 290 × 170 × 85, installation dimensions (mm): 290 × 170.

三相三线智能电能表三相三线智能电能表三相三线智能电能表三相三线智能电能表