AMC96L-E4/KCTBThree phase power meterIt can measure electrical parameters in a single-phase power grid, such as three-phase voltage, single-phase current, active power, reactive power, power factor, grid frequency, etc. It has bidirectional energy metering function and can measure harmonic content in the power grid. It can be widely used in substation automation, distribution automation, intelligent buildings, and internal energy measurement, management, and assessment of enterprises. The measurement accuracy is 0.5 level, and on-site display and remote RS-485 digital interface communication are achieved using the MODBUS-RTU communication protocol.
Three phase electricity meterIt is an electrical device used to measure and record the energy consumption in the power system. This type of electricity meter is usually installed on switchgear to monitor and control the use of electrical energy. It can also be equipped with various additional functions, such as remote meter reading, energy management, data collection, etc., to meet the needs of different users.

1. It can measure three-phase voltage, three-phase current, active and reactive power of each phase, total active power, total reactive power, power factor, frequency, and four quadrant energy, and can achieve multi rate energy metering.
2、Measure the total harmonic distortion (THD) of the 2-31st order of the voltage and current in the power grid.
3. Support event recording, demand, and extreme value statistics;
4. Supports two-way switch output and four-way switch input, can be configured as alarm output or remote control;
5. Supports two analog outputs, with the ability to configure corresponding output electrical parameters (AMC96) as desired;
6. LCD display, backlight delay off time can be set; In addition to displaying electrical parameters and energy values, LCD can also display information such as current quadrant and load rate;
7. Modbus RTU protocol/DL/T645-07 protocol is adaptive; The baud rate can be set from 1200bps to 38400bps, and the parity bit can be set;
1. Active power accuracy: 0.5S level, reactive power accuracy: 2 level, voltage and current accuracy: 0.2 level;
2. Voltage specifications: AC 3 × 57.7V/100V (100V), 3 × 220V/380V (400V), 3 × 380V/660V (660V) (AMC96 only);
3. Current specifications: AC 1A, 5A (connected through a transformer);
4. Working temperature: -25 ℃~+60 ℃
5. Relative humidity: ≤ 95% (no condensation)
6. 485 communication, Modbus RTU protocol/DL/T645-07 protocol adaptive; The baud rate can be set from 1200bps to 38400bps, and the parity bit can be set;
Support 4DI2DO/2DI2DO+1EP(AMC72), 4DI2DO+1EP/2DI2DO2M+1EP(AMC96);
8. Support active pulse output;
9. Dimensions: 75 * 75 * 94.3, opening 67 * 67 (AMC72); 96 * 96 * 77.8, opening 88 * 88 (AMC96);


Installation method:
1). On the fixed distribution cabinet, choose a suitable location to open an installation hole of the appropriate size.
2). Remove the instrument panel, loosen the positioning screw, and remove the fixing clip.
3). Insert the instrument into the instrument hole of the distribution cabinet.
4). Insert the fixing clip of the instrument and fix the positioning screw.

Three phase four wire 380V wiring method

Three phase three wire 10kv/100V wiring method
The Acrel-3000WEB power management system can adopt various power parameters installed in centralized low-voltage switchgear, floor distribution boxes, end power cabinets, embedded multifunctional instruments, rail type multifunctional instruments, and wireless IoT instruments. The system provides real-time online monitoring of electricity data, fault alarms, remote control, energy consumption statistics, energy efficiency analysis, and other functions. It has the characteristics of stability, reliability, easy access, and user-friendly interface, and can meet the comprehensive power management needs of various application scenarios such as enterprises, hospitals, universities, and large public buildings.