Thermo Fisher Scientific Thermal Nitrogen Oxide Analyzer Measurement Board Discount
Jianshuo Scientific Equipment (Shanghai) Co., Ltd. specializes in the agency of consumables and accessories for the American Thermoelectric Original Absorption Spectrometer series, including full line liquid chromatography consumables, full line ion chromatography consumables, full line mass spectrometry consumables, full line environmental monitoring equipment consumables, and full line biological instrument consumables. The original products are authentic, and commonly used products are in stock.
Thermo Fisher Scientific Thermal Nitrogen Oxide Analyzer Measurement Board Discount
Features:
Using chemiluminescence method
L can be remotely accessed on the local area network
Large screen LCD display
User defined 'soft key' function
Users can remotely download analysis results
Enhance data storage performance with flash memory
The optimized design enhances the universality and integration of the circuit
Easy to maintain internal layout
42i type nitrogen oxide (NO-NO2-NOX) analyzer
range
0-0.05,0.1,0.2,0.5,1,2,5,10,20,50,100ppm
0-0.1,0.2,0.5,1,2,5,10,20,50,100,150,mg/m3
Zero point noise
0.20 ppb RMS (60 second average time)
Zuidi detection limit
0.40 ppb (60 second average time)
Zero drift (24 hours)
<0.40ppb
Cross float (24 hours)
± 1% full scale
42i-LS low concentration pollution source nitrogen oxide (NO-NO2-NOX) analyzer
range
0-0.2,0.5,1,2,5,10,20,50,100,200,500ppm
0-0.5,1,2,5,10,20,50,100,200,500,750mg/m3
Zero point noise
<0.005 ppm RMS (60 second average time)
Zuidi detection limit
0.01 ppm (60 second average time)
Zero drift (24 hours)
0.005 ppm
Cross float (24 hours)
± 1% full scale
42i-TL Trace Nitrogen Oxide (NO-NO2-NOX) Analyzer
range
0-5,10,20,50,100,200,500,1000 ppb
0-10,20,50,100,200,500,1000,2000 μg/m3
Zero point noise
<25 ppt RMS (120 second average time)
Zuidi detection limit
50 ppt (average time of 120 seconds)
Zero drift (24 hours)
Can be ignored
Cross float (24 hours)
± 1% full scale
42i-HL high concentration nitrogen oxide (NO-NO2-NOX) analyzer
range
0-10,20,50,100,200,500,1000,2000,5000 ppm
0-20,50,100,20,500,750,1000,2000,5000,7500 mg/m3
Zero point noise
25 ppb
Zuidi detection limit
50 ppb
Zero drift (24 hours)
50 ppb
Cross float (24 hours)
± 1% full scale