Thermo Fisher Scientific Thermal Nitrogen Oxide Analyzer Measurement Board Discount

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Thermo Scientific Thermo Scientific The 42i NO-NO2-NOx analyzer uses chemiluminescence technology to measure the concentration of nitrogen oxides (NO-NO2-NOx) in pollution source emissions. $r $n understands iQ and achieves intelligent operation through our next-generation 42iQ NO-NO2-NOx analyzer.

Product Details

Thermo Fisher Scientific Thermal Nitrogen Oxide Analyzer Measurement Board Discount

Jianshuo Scientific Equipment (Shanghai) Co., Ltd. specializes in the agency of consumables and accessories for the American Thermoelectric Original Absorption Spectrometer series, including full line liquid chromatography consumables, full line ion chromatography consumables, full line mass spectrometry consumables, full line environmental monitoring equipment consumables, and full line biological instrument consumables. The original products are authentic, and commonly used products are in stock.

Thermo Fisher Scientific Thermal Nitrogen Oxide Analyzer Measurement Board Discount

Features:

Using chemiluminescence method

L can be remotely accessed on the local area network

Large screen LCD display

User defined 'soft key' function

Users can remotely download analysis results

Enhance data storage performance with flash memory

The optimized design enhances the universality and integration of the circuit

Easy to maintain internal layout

42i type nitrogen oxide (NO-NO2-NOX) analyzer

range

0-0.05,0.1,0.2,0.5,1,2,5,10,20,50,100ppm

0-0.1,0.2,0.5,1,2,5,10,20,50,100,150,mg/m3

Zero point noise

0.20 ppb RMS (60 second average time)

Zuidi detection limit

0.40 ppb (60 second average time)

Zero drift (24 hours)

<0.40ppb

Cross float (24 hours)

± 1% full scale

42i-LS low concentration pollution source nitrogen oxide (NO-NO2-NOX) analyzer

range

0-0.2,0.5,1,2,5,10,20,50,100,200,500ppm

0-0.5,1,2,5,10,20,50,100,200,500,750mg/m3

Zero point noise

<0.005 ppm RMS (60 second average time)

Zuidi detection limit

0.01 ppm (60 second average time)

Zero drift (24 hours)

0.005 ppm

Cross float (24 hours)

± 1% full scale

42i-TL Trace Nitrogen Oxide (NO-NO2-NOX) Analyzer

range

0-5,10,20,50,100,200,500,1000 ppb

0-10,20,50,100,200,500,1000,2000 μg/m3

Zero point noise

<25 ppt RMS (120 second average time)

Zuidi detection limit

50 ppt (average time of 120 seconds)

Zero drift (24 hours)

Can be ignored

Cross float (24 hours)

± 1% full scale

42i-HL high concentration nitrogen oxide (NO-NO2-NOX) analyzer

range

0-10,20,50,100,200,500,1000,2000,5000 ppm

0-20,50,100,20,500,750,1000,2000,5000,7500 mg/m3

Zero point noise

25 ppb

Zuidi detection limit

50 ppb

Zero drift (24 hours)

50 ppb

Cross float (24 hours)

± 1% full scale