Thermo Fisher Scientific 42i 220-240VAC manufacturer

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Thermo Scientific The 42i NO-NO2-NOx analyzer uses chemiluminescence technology to measure the concentration of nitrogen oxides (NO-NO2-NOx) in pollution source emissions. $r $n understands iQ and achieves intelligent operation through our next-generation 42iQ NO-NO2-NOx analyzer.

Product Details

Thermo Fisher Scientific 42i 220-240VAC manufacturer

Jianshuo Scientific Equipment (Shanghai) Co., Ltd. specializes in the agency of consumables and accessories for the American Thermoelectric Original Absorption Spectrometer series, including full line liquid chromatography consumables, full line ion chromatography consumables, full line mass spectrometry consumables, full line environmental monitoring equipment consumables, and full line biological instrument consumables. The original products are authentic, and commonly used products are in stock.

Thermo Fisher Scientific 42i 220-240VAC manufacturer

Product performance

The 42i chemiluminescence analyzer, combined with detection technology, easily utilizes menu driven software and advanced diagnostics to provide extreme adaptability and reliability. The 42i analyzer has the following characteristics:

320 * 240 LCD image display

Menu driven software

Regional adjustable range

User selectable single/dual/automatic range mode

Multiple user-defined simulation outputs

Analog input selection

high sensitivity

Fast response time

Full range linearity

Independent NO-NO2-Nox range

NO2 converter is an alternative option

User selectable digital input/output capacity

Standard communication features include RS232/485 and Ethernet

C-Link, MODBUS protocol and working principle of mobile data protocol

The principle of the 42i analyzer is based on the chemiluminescence reaction between nitric oxide (NO) and ozone (O3) to produce excited NO2 molecules. When the excited NO2 molecules return to the ground state, they emit light of a certain energy. The intensity of the emitted light is linearly related to the concentration of NO. The 42i analyzer uses the detection light intensity to detect NO. Its chemical reaction equation is as follows:

When detecting nitrogen dioxide (NO2), the instrument must first convert NO2 to NO and then detect it through chemiluminescence reaction. NO2 is converted to NO through a molybdenum converter The heating temperature of its converter is about 325 ℃ (optional stainless steel converter heating temperature is 625 ℃). As shown in Figure 1-1, the sample gas is drawn into the 42i analyzer through the inlet labeled SAMPLE, and then filtered through a particulate filter to reach an electromagnetic valve. The electromagnetic valve selects whether the sample gas path directly reaches the reaction chamber (NO measurement mode) or first passes through the NO2 to NO converter before entering the reaction chamber (NOX measurement mode). Install a limited flow capillary tube and flow sensor in front of the reaction chamber to control and measure the flow rate of the sample gas. Dry air enters the 42i analyzer through the DRY AIR inlet. After passing through the flow sensor, the dry air passes through the discharge type ozone generator. Ozone generators generate high concentrations of ozone required for chemical fluorescence reactions. Ozone reacts with NO in the sample gas to generate excited NO2 molecules, which are then detected by a photomultiplier tube for the fluorescence emitted when NO2 returns to the ground state. The instrument calculates the concentrations of NO and NOX detected in NO and NOX modes, stores the calculation results in memory, and uses the difference between the two concentrations to calculate the NO2 concentration.

The 42i instrument can not only display the concentration values of NO, NO2, and NOX on the front panel, but also output these values to the instrument's analog output terminal