Temperature and humidity controller
Model DDFB130
I. Overview
This product integrates temperature and humidity collection, display, monitoring, alarm, and control. Built in imported temperature and humidity sensor chip, with high detection accuracy and stable performance. This product has three relay outputs, which can be controlled by the device to regulate the temperature and humidity inside the greenhouse, including the rolling shutter, ventilation fan, and heater. This product has bothRS485Communication interface, capable of remote network monitoring, real-time monitoring and recording of temperature and humidity changes in multiple greenhouses through remote computers. It can also be equipped with sound and light alarms, which automatically sound when the temperature and humidity inside the greenhouse exceed the set values.
DDFB130The probe is made of powder metallurgy and has dustproof and waterproof properties, strong protective ability, and is suitable for occasions with large dust and harsh environments.
2、 Technical indicators
3、 Dimensional drawing
Figure 1 External dimensions Figure 2 DB130 probe size diagram


4、 Button Description
Keyboard Settings
SET:Function key, confirmation key
▲: Up key
▼: Down button
5、 Operating instructions
Button operation |
digital display |
explanation |
||
long press”SET”5秒以上 |
Modify with ▲ and ▼ |
|
|
Can only browse parameters, cannot be modified |
|
|
Parameters can be modified |
||
short press”SET” |
Modify with ▲ and ▼ |
|
|
Automatic operation status |
|
|
Manually open |
||
|
|
Manual shutdown |
||
short press”SET” |
Modify with ▲ and ▼ |
|
|
Automatic operation status |
|
|
Manually open |
||
|
|
Manual shutdown |
||
short press”SET” |
Modify with ▲ and ▼ |
|
|
Automatic operation status |
|
|
Manually open |
||
|
|
Manual shutdown |
||
short press”SET” |
Modify with ▲ and ▼ |
|
|
temperature upper limit |
short press”SET” |
Modify with ▲ and ▼ |
|
|
lower temperature limit |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Upper limit of humidity |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Lower limit of humidity |
short press”SET” |
Change password with ▲ and ▼ |
|
|
Password is not equal to 123 , Display , ExitEND |
Enter internal parameter settings | ||||
|
Modify with ▲ and ▼ |
|
|
When the temperature or humidity upper limit alarm is triggered, the ventilation valve opens |
short press”SET” |
Modify with ▲ and ▼ |
|
|
When the temperature or humidity lower limit alarm is triggered, the ventilation valve opens |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Temperature correction value |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Humidity correction value |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Temperature rise difference |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Temperature return difference |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Humidity return difference |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Difference in humidity return |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Communication parameter address, can be set01-63 |
short press”SET” |
Modify with ▲ and ▼ |
|
|
Communication parameter baud rate, representing9600, can be set1.2,2.4,4.8,9.6default9600 |
short press”SET” |
|
|
|
exit |
6、 Wiring diagram


Figure 3 Power supply and RS485 wiring diagram 4 Relay wiring diagram
7、 Communication instructions
The instrument adoptsModbusCommunication protocol, the default value of the local address is03通道。
The protocol format is as follows:
address command Register Address High Bit Low bit register address High bit data length Low data lengthcrclow positioncrchigh position
Address:1~63;
Command:
03Simultaneously reading temperature, humidity, and dew point values;
06: Set the lower computer register value
01: Display register values
04Relay control (in upper computer control mode), followed by01、02、04、08It is to turn off the corresponding relay,10、20、40、80It is to turn on the corresponding relay;
Register address definition:
03The address corresponding to the command(16bit):
address0000 : Humidity
address0001 : Temperature
address0002 Dew point
For example, reading the address as1The temperature and humidity command for the lower computer:
01 03 00 00 00 03 CB 05
06The address corresponding to the command(8bit)
address16: Local address
address17Humidity upper limit alarm value
address18Humidity lower limit alarm value
address19Temperature upper limit alarm value
address20: Temperature lower limit alarm value
address21Humidity alarm return setting
address22Temperature alarm hysteresis setting
address23: Control mode(0Upper computer control,1Local control)
Specific settings can be made using our software or by adding programming; Our software is as follows

8、 Precautions
1The power supply voltage is 12-24VDC
2Do not forcefully pull or tug on the probe lead.
3If measuring under humidity conditions above 90% RH, pay attention to environmental ventilation to prevent condensation on the probe part, which may affect the measurement.
4Without the manufacturer's permission, it is strictly prohibited to open the controller casing to prevent damage to the controller circuit.