Steel flue gasCO2Capture teaching simulation equipment
The device can prepare steel flue gas and adsorb and capture the flue gas insideCO2Gas, analytical recoveryCO2Gas to achieve adsorbent regeneration. The device can be automatically controlledN2TheCO2Gas injection flow rate, real-time collection of pressure and temperature before and after flue gas adsorptionCO2Concentration and other parameters.
The safe operation of the instrument involves the personal safety of the operator and the normal service life of the instrument. The manufacturer reminds the operator to pay attention to the following points:
*All types of instruments and computers must ensure correct power input and be equipped with automatic voltage stabilization protection devices.
*Ensure that all parts of the instrument have good grounding.
*The pressure of each part of the process manifold should not exceed the design pressure, especially not exceed the range of various detection instruments. Extra caution must be taken when using gas pressurization.
*The valve design of the instrument is manual operation. Please pre design the test process according to the test steps. Any valve operation error may lead to the failure of the entire test.
*When operating the system at high temperatures, insulated gloves must be worn to prevent burns.
All instruments have been installed and tested before leaving the factory. For the convenience of packaging and transportation, the instrument is divided into different parts for packaging. Please carefully refer to the flowchart during installation.
The installation work can also be jointly completed by the factory's technical personnel and the user, so that the user can further familiarize themselves with the instrument and facilitate daily maintenance in the future.
Load adsorbent into the capture tower.
adjustN2Flow rate, injected into the mixer.
adjustCO2Flow rate, injected into the mixer.
Configure steel flue gas through a mixer.
By importingCO2Concentration sensor for measuring and preparing flue gasCO2Concentration.
The smoke passes through the capture tower,CO2Being adsorbed.
Through exportCO2Measurement of adsorbed flue gas by concentration sensorCO2Concentration.
After adsorption is completed, it is analyzed by heating and evacuatingCO2Regenerate the adsorbent.
The pressure regulating valve should be cleaned regularly.
Flow meters should avoid strong vibrations. For detailed precautions, please refer to the flow meter manual.
The computer equipped with this instrument is a dedicated control machine for the instrument. Do not copy software randomly, especially those of unknown originUSB drives and computer viruses may cause confusion and errors in control and data collection.
All parts of the instrument that come into contact with the medium are made of stainless steel, which has a certain degree of corrosion resistance, but it is not a one-time solution. The process manifold needs to be cleaned regularly. When the process is not in use for a long time, the process manifold should be dried with high-pressure air to prevent rust and corrosion.
Long term use can cause normal damage to the process seals, affecting their sealing performance. Therefore, it is recommended to regularly conduct pressure tests on the instruments to ensure their integrityReplace the seal for the leaked part, and for regular users, a cycle of 3 months is recommended.