- Phone
-
Address
101, Private No.1 Comprehensive Building, Intersection of Mingzhu Road and Taiping Road, Jianhu County, Jiangsu Province
Yancheng Tianyue Instrument Co., Ltd
101, Private No.1 Comprehensive Building, Intersection of Mingzhu Road and Taiping Road, Jianhu County, Jiangsu Province
OneProduct Introduction
TY-2023The Type A comprehensive atmospheric sampler (with heating) uses solution absorption method to collect harmful gases in the ambient atmosphere,Filter membrane weighing method for capturing total suspended particles in the ambient atmosphere(TSP)And inhalable particles(PM10ThePM2.5).
Equipped with constant temperature heating function. This device is suitable for departments such as environmental protection, health, labor, and scientific research,Stable product performance and easy operation.
two.execution standard
HJ 618-2011The Environmental AirPM10andPM2.5The method of determining weight
HJ/T 374-2007Technical requirements and detection methods for total suspended particulate matter samplers
HJ/T 375-2007Technical Requirements and Testing Methods for Environmental Air Samplers
HJ/T 376-2007《24Technical Requirements and Testing Methods for Hourly Constant Temperature Automatic Continuous Environmental Air Sampler
HJ 93-2013Environmental Air Particulate Matter(PM10andPM2.5)Technical Requirements and Testing Methods for Samplers
HJ 656-2013Environmental Air Particulate Matter(PM2.5)Manual monitoring method(gravimetric method)Technical Specifications
JJG 943-2011Total suspended particulate matter sampler
JJG 956-2013Verification Regulations for Atmospheric Samplers
three.Product features
1.Intelligent flow control: Adopting high precisionPIDClosed loop control technology, real-time monitoring and automatic compensation of flow deviation caused by voltage fluctuations, resistance changes, and temperature effects, ensuring constant flow sampling, equipped with flow calibration software, further improving sampling accuracy.
2.***Diaphragm pump designBuilt in high-performance diaphragm pump, featuring corrosion resistance, low noise, and long lifespan, while equipped with overload protection function to ensure stable operation of the equipment in complex environments.
3.Anti reverse suction protection system:Adopting a dryer design, it effectively prevents the phenomenon of absorption liquid backflow caused by misoperation, provides additional protection for the instrument, and enhances the safety of the sampling process.
4.Particle filtration function:Built in high-quality dust filter element, achieving particle filtration, avoiding particles from entering the air path and interfering with sampling, while protecting the sampling pump and air path system, extending the service life of the equipment.
5.Flexible sampling design:The atmospheric sampling adopts a dual channel independent control design, supporting the simultaneous collection of two gases or parallel samples. The sampling method is flexible and meets diverse monitoring needs.
6.Low noise, long-life fanThe particulate matter sampling adopts a brushless control fan with low noise and high load, suitable for long-term continuous operation, ensuring stable and reliable sampling process.
7.Anti static sampling head:TSP/PM10/PM2.5The sampling head is made of aluminum alloy material, which has anti-static adsorption characteristics to ensure the accuracy of sampling data.
8.Real time environment compensation:Built in real-time pressure and temperature monitoring system, automatically compensates for flow deviation, further optimizes sampling accuracy, and ensures data reliability.
9.Intelligent display and interaction:Equipped with automatic adjustmentbrightnessChinese LCDtouchDisplay screen, suitable for use in low-temperature environments, with a simple and intuitive interface, achieving * * human-machine interaction.
10.Intelligent volume conversion:Automatically calculate the cumulative sampling volume and convert it to the sampling volume under standard conditions in real-time based on air pressure and temperature, simplifying the data processing flow.
11.Power outage recovery function:During the sampling process, the current state is automatically memorized, and when power is restored after a power outage, the sampling task can be automatically resumed to ensure the continuity of the sampling work.
four.Technical Specifications
| Main parameters | parameter range |
resolution |
accuracy |
Atmospheric sampling flow rate |
(10~300)mL/min (20~500)mL/min (50~1500)mL/min (100~3000)mL/min (500~5000)mL/min (Choose one) |
1ml/min |
superior to±2.5% |
Particle flow rate |
(60~130)L/min | 0.1L/min | superior to±2.5% |
sampling time |
1min~99h59min | 1min | superior to±0.1% |
delay time |
1min~99h59min | 1min | superior to±0.1% |
interval |
1min~99h59min | 1min | superior to±0.1% |
traffic stability |
superior to±2.5% | ||
Traffic repeatability |
superior to±2.5% |
||
| Battery working time | greater than3Hour (without heating) | ||
sampling times |
1~99time | ||
| ***Sampling volume | Particulate matter:999999.9L atmosphere:9999.9L |
||
| Operating Temperature | (-20~55)℃ | ||
| noise | ≤60db | ||
| working power supply | 220V/ACorDC11.1V | ||
| host size | 370mm*155mm*260mm |
||
| weight | about5.5kg | ||
Effective filter membrane diameter |
φ80mm | ||
five.Configuration List
| name | quantity |
| host | a |
| Instrument box | a |
| power cord | a |
| charger | a |
| Air connection pipe | four roots |
| tripod | a |
| glass fiber filters |
a box |
| Filter membrane box | one |
| hanger | one |
| drying cylinder |
two |
| Instruction manual/certificate of conformity/warranty card | a copy |