Welcome Customer !

Membership

Help

Beijing Tianyu Wote Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Tianyu Wote Instrument Technology Co., Ltd

  • E-mail

  • Phone

    13810382227

  • Address

    303, Building 13, No.1 Chaoqian Road, Changping District Science and Technology Park, Beijing

Contact Now

TW-56 series online environmental protection instrument

NegotiableUpdate on 03/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Brief description: The TW-56 series online environmental protection instrument adopts the principle of photoelectric colorimetry to measure COD, ammonia nitrogen, total phosphorus, total nitrogen, and various heavy metals, reflecting common indicators of organic and inorganic oxidizable substance pollution in water bodies. Widely used in wastewater treatment, purified water, circulating water, boiler water and other systems, as well as in electronic, electroplating, printing and dyeing, chemical, food, pharmaceutical and other process fields, it has powerful functions in remote monitoring system applications such as surface water and pollution source emissions.
Product Details

brand other brands Application field Environmental protection, food, chemical, petroleum, electronics

1TW-56 series online environmental protection instrumentIntroduction

This series of products adopts the principle of photoelectric colorimetry to measure COD, ammonia nitrogen, total phosphorus, total nitrogen, and various heavy metals, reflecting common indicators of organic and inorganic oxidizable substance pollution in water bodies. Widely used in wastewater treatment, purified water, circulating water, boiler water and other systems, as well as in electronic, electroplating, printing and dyeing, chemical, food, pharmaceutical and other process fields, it has powerful functions in remote monitoring system applications such as surface water and pollution source emissions.

2TW-56 series online environmental protection instrumentBasic Principles

The components to be tested in the water sample react with reagents A, B, C, etc. to produce substances of different colors. The analyzer detects this color change and calculates the corresponding components to be tested within the range of Beer's law.

3. Characteristics

1) Large screen LCD and touch screen display, intuitive and easy to operate;

2) The quantitative system adopts American photoelectric quantitative technology, which provides more precise and accurate sampling;

3) Having dual filtering function, it can adapt to water with high suspended solids, impurities, and floating objects;

4) Adopting Masterflex peristaltic pump technology from the United States;

5) The pump tube adopts * ultra wear-resistant pump tube;

6) All pipelines are made of imported 3-fluorine and 4-fluoro materials that are resistant to high temperatures and corrosion, with an inner diameter of 1.5mm and no leakage;

7) The sampling system adopts Germany's nine way valve technology to eliminate the pressure and aging of pipelines;

8) Scheduled pipeline cleaning (adjustable time), cleaning the pipeline each time (adjustable switch);

9) Store 20000 records for easy retrieval of historical data;

10) Equipped with analog and digital interfaces for easy data transmission;

5. Main technical indicators

Technical Specifications

1、 General technical indicators

Sample interval: continuous, 1 hour, 2 hours... 24 hours, trigger, time

Calibration interval: manually or automatically at selected intervals and times (1-7 days)

Cleaning interval: manually or automatically at selected intervals and times (1-7 days)

Maintenance interval:>1 month, approximately 1 hour each time; Reagent consumption: Approximately 358 samples per set of reagents

Human computer interface: 7-inch, 70000 colors, 800 * 480 resolution, TFT true color touch screen

Data printing: Mini printer printing function (optional)

Data storage: 20000 pieces of data, not lost in case of power failure, automatically overwrite the earliest data when full (can add 40000 pieces of data)

Data query: supports the function of querying historical data, historical data trend charts, historical alarm records, and historical correction parameters

Data identification: capable of displaying the identification of each data, such as "C" representing calibration data, "M" representing manual sample data,

SC "represents standard sample verification (required for certification by China Environmental Monitoring Station)

Unit conversion: The instrument has a manual switching function between mg/L and ug/L, and after switching, all numbers such as the unit of the current value and historical data are converted

According to the requirements of China Environmental Monitoring Station certification, all units have been adjusted to units

Operation log: Any operation on the instrument can be queried in the operation log

(To prevent artificial falsification of data, set scope, and meet the requirements of certification by the China Environmental Monitoring Station)

System language: Supports Chinese, English, and Traditional Chinese

Communication interface: 1 RS232 digital interface or RS485, supporting MODBUS communication protocol or custom protocol

1 analog signal 4-20mA (20mA corresponding value adjustable)

Overall dimensions

915 mm x 600 mm x 450 mm (height x width x depth)

weight

50kg

power supply

AC 220V ± 20%, 50Hz ± 1%

power

500W

ambient temperature

5~40℃

ambient humidity

≤85%

2、 Various instrument technical indicators

1. TW-5618 Online COD Analyzer (Chromium Method)

Measurement method: Potassium dichromate high-temperature digestion, colorimetric determination (national standard GB 11914-89)

Test Range: (0-200) mg/l, (0-1000) mg/l, (0-2000) mg/l, (0-5000) mg/l Available in Four Levels

Maximum testing range: 0-40000mg/l (after automatic dilution); Anti chloride ion interference: up to 5000mg/l

Offline detection: 8 mg/l; Resolution:<1mg/l; Accuracy: Standard solution<5%, water sample<10%

Reproducibility:<3%; Range drift: ± 3% F.S; *Running time: ≥ 720h/time

Dissolving temperature: 165 ℃, adjustable; Dissolving time: 15 minutes, adjustable

2. TW-5678 online permanganate index analyzer (manganese method)

Measurement method: Potassium permanganate spectrophotometric method

Test range: (0-5), (0-20), (0-50) mg/l with three selectable ranges, expandable

Detection limit: 0.05 mg/l; Resolution:<0.02mg/l; Accuracy: Standard solution<5%, water sample<10%

Reproducibility:<5%; Range drift: ± 5% F.S; *Running time: ≥ 720h/time

3. TW-5638 online ammonia nitrogen analyzer (photoelectric method)

Measurement method: Distillation separation, Nessler spectrophotometric colorimetric method

Test range: (0-4) mg/l, (0-15) mg/l, (0-50) mg/l, (0-300) mg/l, four levels of automatic range switching.

Detection limit: 0.05 mg/l; Resolution:<0.02mg/l; Accuracy: Standard solution<10%, water sample<15%

Reproducibility:<3%; Range drift: ± 5% F.S; *Running time: ≥ 720h/time

4. TW-5688 Online Total Phosphorus Analyzer

Measurement method: Potassium persulfate high-temperature digestion, ammonium molybdate colorimetric method

Test range: (0-1), (0-2), (0-10), (0-20) mg/l with four selectable ranges, expandable

Maximum testing range: 0-100mg/l (after automatic dilution); Dissolving temperature: 120 ℃; Reaction time: 15 minutes, adjustable

Offline detection: 0.01 mg/l; Resolution:<0.001mg/l; Accuracy: Standard solution<5%, water sample<10%

Reproducibility:<5%; Range drift: ± 5% F.S; *Running time: ≥ 720h/time

5. TW-5698 Online Total Nitrogen Analyzer

Measurement method: Alkaline potassium persulfate high-temperature digestion, spectrophotometric method (improved method according to national standard GB11894-89)

Test Range: (0-1.0) mg/l, (0-4) mg/l, (0-15) mg/l, (0-200) mg/l Available in Four Levels

Offline detection: 0.01 mg/l; Resolution:<0.001mg/l; Accuracy: Standard solution<5%; Water sample<10%

Reproducibility:<5%; Range drift: ± 5% F.S; *Running time: ≥ 720h/time

6. Other measurable parameters include:

1) Measurement parameters: nitrate, nitrite, total lead, total mercury, total cadmium, hexavalent chromium, total chromium, total arsenic, total copper, total nickel, total cobalt, total cyanide, cyanates, boron, sulfides, fluorides, silver ions, iron ions, aluminum ions, residual chlorine, total chlorine, volatile phenols, total manganese, total beryllium, total color developer, total antimony, silicon, total tin, total uranium, etc.

2) Measurement method: photoelectric colorimetric method