Product Overview:
This instrument is a portable measuring device,The usage method of coating thickness gauge,It can measure the thickness of coatings quickly, without damage, and with precision. Can be used in laboratories,High precision coating thickness gauge,It can also be used on construction sites. By using different probes,German Fischer dualscope mpo coating thickness gauge,It can also meet various measurement needs. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commercial inspection and other testing fields. It is an essential instrument for material protection professionals. This instrument complies with the following standards: GB/T 4956-1985 Measurement of Non Magnetic Coating Thickness on Magnetic Metal Substrate Magnetic Method GB/T 4957-1985 Measurement of Non Conductive Coating Thickness on Non Magnetic Metal Substrate Eddy Current Method JB/T 8393-1996 Magnetic and Eddy Current Coating Thickness Measuring Instrument JJG 889-95 "Magnetic Resistance Thickness Gauge" JJG 818-93 "Eddy Current Thickness Gauge"
Functional features:
This instrument adopts two thickness measurement methods, magnetic and eddy current,Heilongjiang Coating Thickness Gauge,Non magnetic coatings (such as zinc, aluminum, chromium, copper, rubber, paint, etc.) on magnetic metal substrates (such as steel, iron, alloys, and hard magnetic steel) and non-conductive coatings (such as rubber, paint, plastic, anodized film, etc.) on non-magnetic metal substrates (such as copper, aluminum, zinc, tin, etc.) can be measured non destructively.
Can use 7 types of probes (F400, F1, F1/90 ° F10、CN02、N1)
● It has two measurement methods: Continuous measurement method and Single measurement method;
● It has two working modes: Direct mode and Group mode (A-B)
There are five statistical measures: Mean, Maximum, Minimum, Number of Tests, and Standard Deviation;
Two methods can be used to calibrate the instrument,Qnix1200 coating thickness gauge,And basic calibration methods can be used to correct the systematic errors of the measuring head;
● With storage function: capable of storing 495 measurement values;
● With deletion function: delete individual suspicious data that appears during measurement,Direct sales from coating thickness gauge manufacturers,All data in the storage area can also be deleted,Phynix coating thickness gauge,In order to conduct new measurements;
● Set limit: Automatic alarm for measurement values outside the limit; And a histogram can be used to analyze a batch of measurement values
● Printing function: capable of printing measurement values, statistical values, limits, and histograms;
● It has the function of communicating with a PC: it can transmit measured values and statistical values to the PC,Dual purpose coating thickness gauge,In order to further process the data;
● Equipped with power undervoltage indication function;
● There is a buzzing sound during the operation process to prompt;
● It has an error prompt function,Electronic coating thickness gauge,Provide error prompts through screen display or beeping sound;
There are two shutdown modes available: manual shutdown mode and automatic shutdown mode
Technical parameters:
|
overburden |
Non magnetic coatings such as organic materials (such as paints, coatings, enamel, porcelain enamel, plastics, and anodizing treatments) |
Non magnetic non-ferrous metal coating (such as chromium, zinc, aluminum, copper, tin, silver, etc.) |
|||
|
The thickness of the covering layer shall not exceed 100 μ m |
The thickness of the covering layer exceeds 100 μ m |
The thickness of the covering layer shall not exceed 100 μ m |
The thickness of the covering layer exceeds 100 μ m |
||
|
Like iron and steel |
The diameter of the measured area is greater than 30mm |
F400 probe 0-400 μ m |
F1 type probe 0-1250 μ m |
F400 probe 0-400 μ m |
F1 type probe 0-1250 μ m |
|
The diameter of the measured area is less than 30mm |
F400 probe 0-400 μ m |
F400 probe 0-400 μ m |
F400 probe 0-400 μ m |
F400 probe 0-400 μ m |
|
|
Such as copper, aluminum |
The diameter of the measured area is greater than 5mm |
N1 type probe 0-1250 μ m |
Only used for N1 type probe with chrome plating on copper 0-40 μ m |
||
|
Plastic, printed circuit non-metallic substrate |
The diameter of the measured area is greater than 7mm |
- |
- |
CN02 probe 10-200 μ m |
|
|
Probe type |
Optional,Concrete coating thickness gauge,See attached table |
|
|
measuring principle |
Magnetic induction and eddy current |
|
|
measuring range |
Probe decision |
|
|
Low resolution limit |
Probe decision |
|
|
Probe connection method |
Split type wire connection (replaceable) |
|
|
Indication error |
A little calibration (um) |
Probe decision |
|
Two point calibration (um) |
Probe decision |
|
|
Measurement conditions |
Minimum curvature radius (mm) |
Probe decision |
|
Diameter of the minimum area of the substrate (mm) |
Probe decision |
|
|
Minimum critical thickness (mm) |
Probe decision |
|
|
Temperature and humidity |
0~40℃ |
|
|
STATISTICS |
Mean, Max, Min |
|
|
way of working |
Direct method and group method (Appl) |
|
|
Measurement method |
Continuous measurement method and Single measurement method |
|
|
Upper and lower limit settings |
have |
|
|
Storage capacity |
495 measurement values |
|
|
Print/Connect Computer |
Comes with a printer/can connect to a computer |
|
|
Shutdown mode |
Manual and automatic |
|
|
power supply |
1/2 nickel hydrogen battery 5 × 1.2V |
|
|
External dimensions |
270×86×47mm |
|
|
weight |
530g |
|
TT260 Coating Thickness Gauge Optional Probe Parameter Table
|
Probe model |
F400 |
F1 |
F1/90 |
F10 |
N1 |
CN02 |
|||
|
Working principle |
magnetic induction |
Eddy Current |
|||||||
|
Measurement range (um) |
0-400 |
0-1250 |
0-10000 |
0-1250 (chrome plating on copper 0-40um) |
10-200 |
||||
|
Low resolution (um) |
0.1 |
0.1 |
10 |
0.1 |
1 |
||||
|
Indication error |
A little calibration (um) |
±[3%H+1] |
±[3%H+10] |
±[3%H+1.5] |
±[3%H+1] |
||||
|
Two point calibration (um) |
±[(1~3)%H+0.7] |
±[(1~3)%H+1] |
±[(1~3)%H+10] |
±[(1~3)%H+1.5] |
- |
||||
|
Measurement conditions |
Minimum curvature radius (mm) |
Convex 1 |
Convex 1.5 |
straightness |
10 |
3 |
straightness |
||
|
Diameter of the minimum area of the substrate (mm) |
ф3 |
ф7 |
ф7 |
ф40 |
ф5 |
ф7 |
|||
|
Minimum critical thickness (mm) |
0.2 |
0.5 |
0.5 |
2 |
0.3 |
unlimited |
|||
Basic configuration:
Host, printer, F-head or N-head, standard sheet set (50um, 100um, 200um, 500um, 1000um), iron or aluminum substrate, charger
Optional attachments:
Probe (F400, F1, F1/90 ° F10、CN02、N1)、 Communication cables, communication software