Toshiba VFAS1-4280KPC-WN1 inverterThe automatic retrieval function can automatically retrieve parameters that are different from the standard factory settings. It is easy to find modified parameters.
User defined text settings can save the parameters set by the user as standard settings. Allow users to set parameters with custom settings.
The LED charging indicator light shows that the main circuit is charging.
Power removal safety function built-in power removal function, compliant with EN954-1 category 3 and IEC/EN 61508-1 SIL2
The input function of the input/output terminal can be selected through the programmable input/output field sub function menu, including positive and negative editing. 1) 2) (Standard factory settings: Normal settings)
Pulse train tilt rate output open collector output (24Vdc, 50mA)
Communication function RS-485 standard 2-channel configuration (interface: modular 8P) Options: CC Link, DeviceNet, PROFIBUS-DPModbus TCP and Modbus Plus
Use the environment indoors. Altitude: below 3000 meters (above 1000 meters, Longrong is required). Do not expose to direct sunlight, corrosive gases, explosive gases, and oil mist gases.
Surrounding temperature -10~+60 ℃ (please remove the top cover when above 40 ℃, max 60 ℃) 4
Storage temperature -25~+70 ℃
Relative humidity 5-95% (no condensation)
By setting parameters, jog operations can be performed through the sub station.

Multi speed operation is carried out by changing the switch combination between S1.S2S3.RR/S4-CC, setting the frequency to+15 speed operation. According to the set lead rate, optional broadcasting or timing, torque limit, and V.
After the retry protection function is activated, it will automatically detect the main circuit components and restart. Up to 10 restarts can be selected. Waiting time adjustment (0-10 seconds).
Toshiba VFAS1-4280KPC-WN1 inverterWhen the soft stall occurs, it will automatically reduce to negative power before starting. (Standard factory setting: closed)
The cooling fan should be turned on/off at the same time as the high front automatic body to ensure long service life.
The panel key operation ON/OFF control can choose to disable the use of the STOP key, MODE key, etc
The use of regenerative energy can keep the motor running even in the event of a power failure, with a clear stop without stopping control. (Standard setting: Off)

The clear stop and restart control can automatically determine the speed and rotation direction of the motor in idle mode and restart the motor. (Standard setting: Off)
The simple mode operation can select 2 sets of 8 modes each from 15 speed runs. Supports up to 16 operating modes. Corresponding terminal block operation/repeated operation.
All keystrokes can be prohibited.