- Phone
-
Address
2507, Zhonghai International Plaza, No. 237 Wannian Quan Road, Licang District, Qingdao City, Shandong Province
Qingdao Dongfang Jiayi Electronic Technology Co., Ltd
2507, Zhonghai International Plaza, No. 237 Wannian Quan Road, Licang District, Qingdao City, Shandong Province
Product Overview:
This instrument is an ultra small measuring device,Penetrating coating thickness gauge,It can quickly, non destructively, and accurately measure the thickness of non-conductive coatings on non-magnetic metal substrates. It can be widely used in manufacturing, metal processing industry, chemical industry, commercial inspection and other testing fields. Due to its small size and integrated probe and instrument,Coating thickness gauge,Especially suitable for on-site engineering measurement.
Alternative products to TT230,How much is the coating thickness gauge,More accurate measurement,Phynix coating thickness gauge,Faster speed,Verification regulations for coating thickness gauges,More convenient operation.
This instrument complies with the following relevant standards:
GB/T 4957-1985 Non conductive coatings on non-magnetic substrates - Measurement of coating thickness - Eddy current method
GB/T 4957-1985 JB/T 8393-1996 Magnetic and Eddy Current Coating Thickness Measuring Instruments
GB/T 4957-1985 JJG 818-93 "Eddy Current Thickness Gauge"
Functional features:
♦ This instrument adopts eddy current thickness measurement method,Maintenance of coating thickness gauge,The thickness of non-conductive coatings on non-magnetic metal substrates (such as enamel, rubber, paint coatings on copper, aluminum, zinc, tin and other substrates) can be measured without damage, and zero point calibration and two-point calibration can be performed,Electromagnetic coating thickness gauge,And basic calibration methods can be used to correct the systematic errors of the measuring head;
♦ Zero point calibration and two-point calibration can be performed,Eddy current coating thickness gauge,And the basic calibration method can be used to correct the systematic errors of the measuring head;;
♦ There are two measurement methods: continuous measurement and single measurement;
♦ There are two working modes: direct mode and batch mode;
♦ Store 500 measurement values;
♦ Has deletion function: delete current value, calibration value, limit value, and all values;
♦ There are five statistical measures: Mean, Maximum, Minimum, Number of Tests, and Standard Deviation;
♦ Equipped with printing function,Xima Coating Thickness Gauge,Printable measurement and statistical values;
♦ Equipped with undervoltage indication function;
♦ There is a buzzing sound during the operation process;
♦ Equipped with error prompt function;
♦ Chinese and English menus;
♦ Backlight display;
♦ Automatic and manual shutdown.
Technical parameters:
|
Probe type
|
N
|
|
|
measuring principle
|
Eddy Current
|
|
|
measuring range
|
0-1250μm
|
|
|
Low limit display resolution
|
0.1 μ m (0.1 μ m below 100 μ m)
|
|
|
Probe connection method
|
integration
|
|
|
Indication error
|
Zero point calibration (um)
|
±[3% H + 1]
|
|
Two point calibration (um)
|
±[(1% ~ 3%) H + 1]
|
|
|
Measurement conditions
|
Minimum curvature radius (mm)
|
Convex 1.5; Concave 9
|
|
Diameter of the minimum area of the substrate (mm)
|
ф7
|
|
|
Minimum critical thickness (mm)
|
0.5
|
|
|
Temperature and humidity
|
0~40℃ ; 20%RH~90%RH
|
|
|
STATISTICS
|
Mean, Max, Min
Test frequency (NO.), standard deviation (S.DEV) |
|
|
way of working
|
Direct method and group method (Appl)
|
|
|
Measurement method
|
Continuous measurement method and Single measurement method
|
|
|
Storage capacity
|
Store 500 measurement values
|
|
|
Print/Connect Computer
|
Optional printer/unable to connect to computer
|
|
|
Shutdown mode
|
There are two modes: automatic and manual
|
|
|
power supply
|
AAA type 1.5V (No. 7) dry battery 2 pieces
|
|
|
External dimensions
|
146×60×28mm
|
|
|
weight
|
132g
|
|
Basic configuration:
TIME2501 host 1 unit; 1 set of standard samples; 1 standard substrate
Optional attachments:
TA230 printer; Communication cable