E-mail
taomsun@vip.163.com
-
Phone
13862625813
-
Address
Building A, Renheng PARK, 1211 Xinghu Street, Suzhou Industrial Park
SUZHOU TAOMSUN SCIENTIFIC INSTRUMENTS CO.,LTD
taomsun@vip.163.com
13862625813
Building A, Renheng PARK, 1211 Xinghu Street, Suzhou Industrial Park
Brand:TAOMSUN |Overseas technical support:METICULAB (Korea) |ISO 9001·Precision optical manufacturing

TAOMSUN 721 visible spectrophotometerThe use of microprocessor control technology for qualitative and quantitative analysis of substances in the visible spectral region (approximately 360nm-1000nm) is a versatile analytical instrument required in conventional laboratories. The core optical system adoptsHolographic glitter grating monochromatorIt has excellent performance such as high wavelength accuracy, good monochromaticity, and low stray light. equipBacklit LCD displayEffectively avoiding pointer reading errors, coupled with a microcomputer measurement system to achieve high-precision T-A conversion, automatic zero/hundred adjustment, and concentration direct reading functions.
🔍 Core features:Holographic scintillation grating monochromator+microcomputer measurement system ensures wavelength accuracy and reading accuracy; Automatic light gate technology protects photoelectric sensors without the need for blackbody operation; High performance tungsten halogen lamps ensure the stability of the light source. Specially designed for teaching and research, quality testing, and production quality control scenarios.
| Product Name | 721 visible spectrophotometer |
| Brand/OEM | TAOMSUN(Overseas partner: METICULAB) |
| optical system | Holographic glitter grating monochromator(High wavelength accuracy, good monochromaticity, low stray light) |
| display mode | Backlit LCD display (to avoid pointer reading errors) |
| measurement system | Microcomputer measurement system, high T-A conversion accuracy, automatic 0% (T)/100% (T) adjustment |
| Concentration direct reading | Support concentration factor setting and concentration direct reading function |
| light source | 12V 20W tungsten halogen lamp(High performance, long lifespan) |
| Light Gate Technology | Automatic light gate technology (no need for blackbody, effectively protecting photoelectric sensors) |
| power supply voltage | AC220V ± 22V,50Hz ± 1Hz |
| rated power | 80W |
| Standard accessories | 5cm colorimetric dish holder(Compatible with 10cm colorimetric dish rack optional) |
| Optional accessories | Serial printer/specialized spectral analysis software |
| Quality System | ISO 9001·Precision optical manufacturing |

Q: What wavelength range is the 721 spectrophotometer suitable for?
A: This product operates in the visible spectrum region, with a typical wavelength range of 360nm-1000nm, and is suitable for most conventional colorimetric analysis experiments.
Q: What are the advantages of backlit LCD compared to traditional pointer LCD?
A: Backlit LCD can avoid reading errors caused by pointer deflection angle, parallax, etc., and display numerical values more intuitively and accurately, especially suitable for batch detection scenarios.
Q: What is the function of automatic light door technology?
A: The automatic light gate can automatically close the light path when not measuring, without the need for blackbody shading, effectively protecting the photoelectric sensor from long-term light aging and extending the service life of the instrument.
Q: Does it support direct reading of concentration? How to operate?
A: Support. Users can directly convert absorbance values into concentration values through the concentration factor setting function, achieving one click direct reading and greatly improving daily detection efficiency.
Q: Can it be adapted to long path colorimetric dishes?
A: Okay. The instrument comes standard with a 5cm colorimetric dish holder and can also be optionally equipped with a 10cm colorimetric dish holder, suitable for the detection needs of low concentration samples.
Q: Does it support data export or printing?
A: A serial printer can be selected to directly print measurement data, or specialized spectral analysis software can be selected for data management and analysis.
TAOMSUNWe are a laboratory analytical instrument supplier that integrates research and development with sales. The production process has passed ISO 9001 quality management system certification, and the product line covers spectrophotometers, spectral analysis instruments, and supporting consumables. The core optical system adopts precision machining and assembly processes to ensure the wavelength accuracy and data reliability of each instrument. The product is widely used in the fields of chemical engineering, medicine, environmental protection, food, and scientific research in universities.🌏 Overseas technical support is provided by METICULAB from South Korea.
TAOMSUN products are manufactured under the ISO 9001 quality management system. The specification parameters are standard configurations, and customized configurations may vary.
If you need OEM/ODM customization, specific wavelength extension, or software feature customization, please contact our sales team. Overseas customers can contact METICULAB (Korea) for Korean/English technical consultation.