- Phone
-
Address
1118 Jintong Road, Shanghai
Shanghai Zhengyuan Electric Technology Co., Ltd./Shanghai High Voltage Tester
1118 Jintong Road, Shanghai
TAG-8800 Remote Wireless High Voltage Nuclear Phase Analyzer Overview
Related standards:
1. The main advantage is the removal of the leads connecting the two power grids (power sources) at both ends, which can pass through walls and partitions (boards) at a distance of up to 20m, without being restricted by any terrain or facility structure, thus improving safety,
2. For convenience, only one person needs to operate and one person needs to supervise.
3. The instrument sends digital signals to the receiving end through a wireless transmission module during operation, thereby reducing interference and errors, greatly improving the performance of the instrument.
4. In use, first operate the receiving device on the conductor of the tested power grid, and then operate the receiving device on another conductor of the tested power grid. If the phases of the two tested power grids are the same, repeat the language prompt: "Phase is the same". If the phases of the two tested power grids are different, repeat the language prompt: "Attention, phase is different".
5. The insulation operation tube (material) is selected from the three ball brand moisture-proof insulation tube produced by the military industry enterprise, which meets the EC/1C78 standard and has the characteristics of moisture-proof, high voltage resistance, impact resistance, bending resistance, etc.
TAG-8800 Wireless High Voltage Nuclear Phase AnalyzerTechnical Specifications:
1. Scope of use: Voltage levels such as 6-35kV, 110KV, 220KV, 500KV, etc
2. Test condition: Live parts of the circuit or equipment
3. Ground clearance: less than 15 meters
4. Large distance between transmitters: less than 30 meters
5. Equipment operating frequency: 1.2GHz
TAG-8800 Wireless High Voltage Nuclear Phase AnalyzerPrecautions and maintenance:
1. When verifying frequency transmission, the antenna must be installed first before verification. The shell of the high-voltage phase detector is made of polycarbonate and must be kept clean. All kinds of dirt or moisture must be wiped off. After each use, the instrument can be wiped with a cloth dipped in a small amount of silicone oil.
2. The instrument must be stored properly in the box when not in use
3. The instrument must be stored in a warm place as required in low-temperature environments (-10 degrees or lower), and the battery may fail due to cold.
4. The instrument should be tested before each use.
The line of sight transmission distance between the host and the X and Y collectors is: X ≥ 80m Y ≥ 50m
Working environment: -35 ℃~+50 ℃ Humidity: ≤ 95% RH
Storage environment: -40 ℃~+55 ℃ Humidity: ≤ 95% RH
Insulated telescopic rod: 600mm in the contracted state and 3200mm in the extended state
Packaging box dimensions (length x width x height): 650mm x 250mm x 100mm
Product total weight: 5kg