AGC Instrument Co., Ltd. in Ireland is the representative office of Swiss ECO company in China, responsible for the sales and after-sales service of ECO nitrogen oxide analyzers in China. It has authorization from Swiss ECO headquarters, and other domestic suppliers are second level agents. If the nitrogen oxide analyzer is not authorized by the headquarters and transferred through abnormal channels, AGC company is not responsible for product after-sales. We hope that all users are aware.
SwitzerlandECO PhysicsThe company is based on chemistrysendPrinciples of Optics and LawproduceAnalysis of various nitrogen oxidesceremonyThe device'smajorCompany, for over ten yearsspecialHeart creates various heightslevelofNO/NO2/NOx/NOy/NH3…analyzeceremonyIn Europe, nitrogen oxidesceremonyThere is a reputation in the device,producePin YimeasureDing FanSurrounding division: can be divided from%topptAccording toshouldUsed to divide and include fluesmonitor、ringEnvironmental airqualityQuantitative analysis, backgroundvalueAnd high-altitude atmospheric research, etc,stillcanshouldUse halfguideBody and human respiration and exhalationdetectWait. againstResponse timecan reach0.1In seconds.produceProduct accuracystableDing.
80/800 seriesFor customization, suitable for multiple purposes, customers can freely choose the measurement range,NO2Converter material, single or dual reaction chamber, suitable for high and low concentrations, fast reaction time, and multifunctional. You can also chooseHot-tubingSuitable for gases with high temperature and humidity.
1、 CLD 822MM DR dual inlet high concentration nitrogen oxide analyzer
CLD 822MM drThe specification adopts two sets of NO2 conversion devices, independent sample gas pipelines and reaction chambers, which can measure two independent sample gases simultaneously. Mainly used in flue gas monitoring.
New Features and Benefits
·Built in dual reaction chamberUsing a dual reaction chamber device, measure the concentration of nitrogen oxides in two independent sample gases simultaneously.
·Adequate response and high efficiencyBuilt in high-voltage ozone generator can generate high concentration ozone and improve reaction efficiency.
·Avoid secondary pollutantsBuilt in high-temperature ozone decomposition device (replacing activated carbon adsorption), maintenance free, no consumables, avoiding secondary pollution.
·Pressure compensation deviceEquipped with an automatic pressure compensation device, it will not affect the measured value due to pressure changes.
·Easy maintenance and low costOnly simple annual maintenance is required, including cleaning the flow restrictor, replacing filter materials, pumping membranes and valves, with low maintenance costs.
CLD 822MM drSpecifications
·Measurement item: Can simultaneously measure the NOx values of two different source gases
·Measurement range: Different measurement ranges from 0-5000ppm, each group can be divided into two sections, and the measurement range can be freely set
·Extremely fast full-scale time:<1 second (T90)
·Gas flow rate: 1.2 l/min
·Conversion device: Built in two sets of NO2 converters
·Low detection value:. 25ppm
·Automatic pressure regulation: 600~1200mbar
2、 CLD 844CM hr high concentration nitrogen oxide/ammonia analyzer
CLD 844 CM hrThe specifications adopt modular design, and suitable instruments can be customized according to customer needs. Built in NH3 and NO2 conversion devices enable simultaneous monitoring of high concentration nitrogen oxides and ammonia gas. Mainly used in flue gas monitoring.
New Features and Benefits
·Built in dual reaction chamberAdopting a dual reaction chamber device to simultaneously measure the concentrations of nitrogen oxides and ammonia in the gas.
·Pipeline heating deviceThe sample gas pipeline is equipped with a heating device to avoid the production of ammonium salts. Ensure the accuracy of the measurement.
·Adequate response and high efficiencyBuilt in high-voltage ozone generator can generate high concentration ozone and improve reaction efficiency.
·Avoid secondary pollutantsBuilt in high-temperature ozone decomposition device (replacing activated carbon adsorption), maintenance free, no consumables, avoiding secondary pollution.
·Pressure compensation deviceEquipped with an automatic pressure compensation device, it will not affect the measured value due to pressure changes.
·Easy maintenance and low costOnly simple annual maintenance is required, including cleaning the flow restrictor, replacing filter materials, pumping membranes and valves, with low maintenance costs.
CLD 844CM hrSpecifications
·Measurement item: Can simultaneously measure and display NOx/NH3/NOx amines or NO/NO2/NOx
·Measurement range: 0.5-500ppm, divided into four sections, freely adjustable measurement range
·Extremely fast full-scale time:<1 second (T90)
·Gas flow rate: 1.2 l/min
·Conversion device: Built in NH3 and NO2 converters
·Low detection value: 0.025ppm
·Gas pipeline heating: can be heated to 190 ℃
·Automatic pressure regulation: 600~1200mbar
3、 CLD 824MM DR dual inlet high concentration nitrogen oxide analyzer
CLD 824MM drThe specification adopts two sets of NO2 conversion devices, independent sample gas pipelines and reaction chambers, which can measure two independent sample gases simultaneously. Mainly used in flue gas monitoring.
New Features and Benefits
·Built in dual reaction chamberUsing a dual reaction chamber device, measure the concentration of nitrogen oxides in two independent sample gases simultaneously.
·Adequate response and high efficiencyBuilt in high-voltage ozone generator can generate high concentration ozone and improve reaction efficiency.
·Avoid secondary pollutantsBuilt in high-temperature ozone decomposition device (replacing activated carbon adsorption), maintenance free, no consumables, avoiding secondary pollution.
·Pressure compensation deviceEquipped with an automatic pressure compensation device, it will not affect the measured value due to pressure changes.
·Easy maintenance and low costOnly simple annual maintenance is required, including cleaning the flow restrictor, replacing filter materials, pumping membranes and valves, with low maintenance costs.
CLD 824MM drSpecifications
·Measurement item: Can simultaneously measure the NOx values of two different source gases
·Measurement range: Different measurement ranges of 0.5-500ppm/5-5000ppm, each group can be divided into two sections, and the measurement range can be freely set
·Extremely fast full-scale time:<1 second (T90)
·Gas flow rate: 1.2 l/min
·Conversion device: Built in two sets of NO2 converters
·Low detection value: 0.025ppm/0.25ppm
·Automatic pressure regulation: 600~1200mbar
4、 CLD 88p high-altitude atmospheric environment photochemical conversion nitrogen oxide analyzer
CLD 88pThe specification uses a photochemical NO2 conversion device combined with an NO analyzer to measure the true concentration of NO2 in the atmosphere; There are two types of photochemical NO2 conversion devices available for combination: PLC 860 or PLC762.
New Features and Benefits
·Sensitivity*The accuracy of measuring nitrogen oxides can reach ppt level. At the same time, after calibration, the conversion efficiency of the instrument will automatically enter the measurement calculation correction, which can record the correction value and the original value. It can be matched with various CLD nitrogen oxide analyzers to improve sensitivity.
·High selectivity conversion deviceAdopting a highly selective photochemical NO2 conversion device, unaffected by HNO3 and PAN.
·Zero drift is extremely smallAdd a front reaction chamber device to reduce zero drift issues (chemical zero correction)
·Full software functionalityThe control software has functions such as data storage, remote control, and ozone correction coefficient calculation.
·Easy maintenance and low costOnly simple annual maintenance is required, including cleaning the flow restrictor, replacing filter materials, pumping membranes and valves, with low maintenance costs.
CLD 88pSpecifications
·Measurement project: capable of measuring the NOx values in high-altitude atmospheric gases or semiconductor research
·Measurement range: 5-5000ppb
·Detection limit: 0.05ppb
·Extremely fast response time:<0.1 seconds
·Extremely fast full-scale time:<0.1 seconds (T90)
·Extremely low gas flow rate: 110 ml/min
·Sampling speed: above 100KHz
·Resolution: 24bits
·Linearity: 1% full body
·Communication interface: USB 2.0 or above 1.1
| model | measurement range | Small detection limit | 通道 | Analyze the components |
| nCLD 62 | 0-5000ppm | 0.25ppm | single | NOTheNO2TheNOx |
| nCLD 62Ox | 0-5000ppm | 0.025ppm | single | NOTheNO2TheNOx +O2(25%) |
| nCLD 63 | 0-500ppm | 0.025ppm | single | NOTheNO2TheNOx |
| nCLD 66 | 0-25ppm | 0.5ppb | single | NOTheNO2TheNOx |
| nCLD 822 | 0-5000ppm | 0.125ppm | double | NOTheNO2TheNOx + NH3 |
| nCLD 844 | 0-500ppm | 0.0125ppm | double | NOTheNO2TheNOx + NH3 |
| nCLD 855 | 0-50000ppb | 0.5ppb | double | NOTheNO2TheNOx |
| nCLD 899 | 0-1000ppb | 0.025ppb | double | NOTheNO2TheNOx |
| nCLD 88yp | 0-5000ppb | 0.05ppb | single | NOTheNO2TheNOx |
| … … |
|
|
|
|
There are also other specifications and ranges for nitrogen oxide analysis, including ppb and ppt level analysis. Please consult customer service.