-
E-mail
Tim@agc-china.com
-
Phone
13911644071
-
Address
6G, Yaoyan Building, Jiulong Mountain Villa, Xihongmen, Daxing District, Beijing
AGC Instruments Ireland Limited Beijing Representative Office
Tim@agc-china.com
13911644071
6G, Yaoyan Building, Jiulong Mountain Villa, Xihongmen, Daxing District, Beijing
1Purity analysis of silane using helium ion gas chromatography
AGC NovaCHROM1000Purity analysis of silane using helium ion gas chromatographyUsing DID helium ionization detector, mainly used for analysis of H2, O2, N2, CH4, CO, CO2, etc. in high-purity silane.
AGC NovaCHROM1000, All connection interfaces use 1/8'VCR to ensure the airtightness of the instrument. The installed valve has undergone strict leakage testing and is installed in a casing with He gas blowing, isolated from the atmosphere. Therefore, environmental pollution is eliminated, ensuring that the instrument has more stability, sensitivity, and longer service life.
2、 Low detection limit:
| AGC NovaCHROM1000Detection limit of helium ion gas chromatograph(ppb) | |||||||||||
| component | H2 | O2 | N2 | CH4 | CO | CO2 | C2H2 | N2O | Ne | Kr | Xe |
| detection limit | 5 | 10 | 10 | 1 | 10 | 10 | 5 | 10 | 10 | 10 | 10 |
3、 Main features:
Equipped with DID helium ionization detector
Can be equipped with two or more detectors
Sensitivity at ppb level
Fast response time ≤ 0.5 seconds (90%)
In addition to the independent large column box, it is also equipped with multiple independent temperature controlled small column boxes
Each chromatographic column has an independent temperature controlled column box
Electropolished stainless steel tube, acid pickling and passivation treatment
Can be equipped with Hastelloy gas path for anti-corrosion treatment
According to the requirements, an optional electromagnetic valve with heating function can be equipped
Integrated Comprehensive Diagnostic System
Long term stability and sensitivity
*Application of automation
Controlled through Trend vision workstation software *
Different gas analysis methods can be customized according to user needs
4、 Technical advantages:
Core components of chromatograph----The DID HFADD FID TCD detector from AGC company is based on the independent research and development of AGC company in Ireland. It has strong performance, high sensitivity and stability, and is the choice for analyzing low content impurities in high-purity gas;
*Parallel connection of dual detectors----AGC company has developed dual detectors for parallel use, equipped with two independent detectors. Their temperature control system and operation are both independent detectors, which can be connected in series or parallel.
Gas path system of chromatograph----The unique center cutting and blowback system technology can complete the analysis and detection of multiple complex components at once;
Chromatography software system----Trend Vision, specially developed for AGC chromatography, can not only complete test reports, automatically analyze/store data, automatically draw spectra, reverse control gas chromatography, adjust retention time and various cutting actions, but also control up to 4 analytical instruments simultaneously;
Carrier gas purification system----The AGC 75-802 carrier gas purifier is a renewable purifier that can purify 5.5N grade gas to above 7.5N. The ultra-high purity carrier gas gives the AGC high-purity gas chromatograph higher sensitivity;
Carrier gas switching device----The configuration of CGDP-01 carrier gas switching device can simultaneously carry two bottles of carrier gas, avoiding the entry of contaminated gas when switching gas sources after the carrier gas is used. The configuration of the carrier gas switching device ensures higher work efficiency and analysis quality of AGC gas chromatography.
5、 High purity silane chromatogram: