Sulfur hexafluoride gas leakage monitoring sensor/power plant/GIS

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The C-series diffuse infrared gas sensor uses the principle of infrared spectral absorption (NDIR) to detect the specific gas content in the gas as an infrared gas n-body sensor. This sensor adopts imported high-precision infrared emission detectors and industrial grade high stability microcontrollers. Its products have the characteristics of long service life, low cost, high precision, and good long-term stability. The default baud rate for TTL232 level serial communication is 9600, with 8 data bits, 1 stop bit, and $r $n even parity; Its output interface is: TTL232 level digital output signal, 0.4-2V voltage output signal.

Product Details



638338393001041001921.jpg


CThe series of diffuse infrared gas sensors adopt the principle of infrared spectral absorption method(NDIR)Detect the specific gas content in the gas using infrared gas

Body sensor. This sensor adopts imported high-precision infrared emission detectors and industrial grade high stability microcontrollers, which have long service life, low cost

High precision and good long-term stability.TTL232The default baud rate for level serial communication is 9600The data bit is 8Position,1Stop position,

Occasional verification; Its output interface is:TTL232Level digital output signal,0. 4~2V Voltage output signal.


Product application:

It can be widely installed in home networks, ventilation systems, industrial controllers, public wall mounted use, pipeline gas detection, environmental monitoring, etc.

3、 Performance parameters:

1 Test environment: Atmospheric pressure:1020 hpa temperature25 Gas flow rate:500ml / mi n

2 Gas detection: in gasCO2Gas content;

3 Working Principle:NDIR

4 Preheating time:<2 minute; (20Best Measurement State per Minute

5 Response time:<5Seconds;

6TheT90

15second( 500ml /Mi n)

7 Recovery time: 25Seconds;

8 Measure flow rate:300--500 mL/Min

9 Resolution: The visual range varies

10Repeatability: ≤±1% FS

11Linear error:≤±1% FS

12Zero temperature drift:≤±0.1% FS/

13Range temperature drift:≤±0.2% FS/

14Working voltage: 5.5 VDC

15Working current: Maximum current 120mA

average current 60 mA

16Working power: <600 mW

17Output signal: 0.4- 2V

voltage type

numeric

TTL232

18Working temperature:- 10- - 50/

19Storage temperature:- 20- - 60/

20Working humidity:0--95%RH (No condensation)

21Work pressure:1±0.2 One atmospheric pressure

22External dimensions: diameter29mm *tall84mm(Excluding pin height).



638338382155449514374.jpg