- Phone
-
Address
Room 0312, Building A, Xianghe Building, Guanyinge Street, Rencheng District, Jining City, Shandong Province
Jining Chengying Trading Co., Ltd
Room 0312, Building A, Xianghe Building, Guanyinge Street, Rencheng District, Jining City, Shandong Province
High pressure breathing air compressor
Types model
JUNIOR II-B |JUNIOR II-E |JUNIOR II-W
| General |
|
| Medium medium | Air air |
| Intake pressure intake | Atmospheric atmospheric pressure |
| Filling pressure inflation pressure | PN200 or PN300 |
| Pressure setting, final pressure safety valve Pressure setting, final safety valve pressure | 225 bar or 330 bar |
| Working pressure Maximum work pressure | 220 bar or 320 bar |
| Permissible ambient temperature range Allowable ambient temperature | +5...+45°C |
| Permissible altitude1 Allowable altitude | 0...1000 m AMSL |
![]()
| Max. permissible tilt Maximum tilt angle | 5° |
| System type system design | Open open |
| Standard operating voltageStandard operating voltage | 400 V; 6 0 Hz |
| Other operating voltage Other operating voltages | On request individual inquiry |
| Compressor oil, standard Compressor lubricating oil-standard | Syntheticsynthetic oil |
| Oil change interval Oil change cycle | Every 2 years/ 1,000 h Every two years or 1000 hour |
| Colouring Finished product color | RAL7024, CYANLike the color and style of the picture |
1 Operating compressors in altitudes > 1000 m AMSL on request
| Compressor system | JUNIOR II-B | JUNIOR II-E | JUNIOR II-W |
| Charging rate 1 traffic | 100 l/min | ||
| Purification system filtration system | P21/350 | ||
| Cooling air flow, min. Cooling air | 660 m³/h | 660 m³/h | 660 m³/h |
| Sound pressure level Sound pressure index | 86 dB[A] | 82 dB[A] | 83 dB[A] |
| Weight ² weight | 44 kg | 46 kg | 46 kg |
| Dimensions (L ×W × H) ² size | 785 × 370 × 440 mm | 690 × 390 × 440 mm | 690 × 400 × 440 mm |
| Dimensions (L ×W × H)withautomatic condensate drain system and control Equipment with automatic condensate discharge system size |
885 × 410 × 435 mm(without control) |
825 × 475 × 495 mm |
825 × 475 × 495 mm |
1 + 20°CThe ambient temperature drops, and the gas cylinder 0 charge to 200barMeasure under certain circumstances. error in+/- 5%
2 Limited to standard models Actual weight and size (may vary depending on configuration)Transformation)
![]()
| Drive system | JUNIOR II-B | JUNIOR II-E | JUNIOR II-W |
| Motor motor | Petrol4-Stroke | Three-phase | Single-phase |
| Power power | 4.2 kW | 2.2 kW | 2.2 kW |
| Fuel consumption 1 Fuel consumption | approx. 1 l/h | - | - |
| Tank volume Fuel pool | 3.6 l | - | - |
| Operating voltage/frequency2 Operating voltage and frequency | - | 440 V, 6 0 Hz | 230 V, 6 0 Hz |
| Rated current current | - | 4.6 A (at440 V/60 Hz) | 13.2 A (at 230 V/60 Hz) |
| Speed approx. rotation speed about | 3,600 1/min | 2,870 1/min | 2,820 1/min |
| Protection class Protection level | - | IP55 | IP54 |
1 200barUnder the condition of final pressure. When the final pressure is300barWhen fuel consumption increases 10% Fuel consumption is also influenced by the quality of the fuel usedThe influence of altitude, ambient temperature, rotational speed, and maintenance status
Different voltages/frequency additional charge
Standard supply scope of compressors
How to translate
The compressor host has the following characteristics
■Splash lubrication10 ■
Dust intake filter: m
■Intermediate stage cooler, air-cooled■ Final stage cooler, air-cooled, outlet temperature higher than ambient temperaturehigh
10-15Degree.
■Upgrade and increase the final stage cooler to improve cooling efficiency and reduce the final stage temperature. ■
Oil water separators at all levels(Except for Level 1)
■Final oil-water separator
■Safety valves at all levels (no arbitrary opening) ■Final safety valve
TÜVCertification (optional)
| ■ |
|
| Final stage pressure maintaining valve and check valve Compressor block 1 Charging | 100 rate |
| trafficl/min | Speed approx. rotation speed2,300 |
| 1/ min | 3 |
| Number of stages series | 3 |
| Number of cylinders number of cylinders Cylinder bore | 60 1st stage |
| Primary cylinder diameter mm Cylinder bore 2nd | 28 stage |
| Secondary cylinder diameter mm Cylinder bore 3rd | 12 stage |
| Third stage cylinder diameter mm | 24 Stroke |
| Piston stroke mm Direction of rotation (from flywheel side)steering | Facing the direction of the flywheel |
| ) Left | Drive typeMotor connection method |
| V- beltOil | 0.36 quantity |
1 fuel level l+ 20° 0 C 2Remove the gas cylinder from the environment at a certain temperaturecharge to00bar
Measure under certain circumstances. error in +/- 5%
How to translate
P21/350Filtering system, integrated oil-water separator ■Final oil-water separator - physical separation ■
TRIPLEXLong lasting filter element, used for drying and oil removal, optional for removal
Carbon monoxide (internal combustion engine driven type)Standard configuration)
■ Final safety valve, installed on the filter cartridge ■Pressure holding valve/check valve, installed on the filter cartridge
Control quality based onDIN/EN
| 12021:2014 | Standard P21/350Filter system image for reference Contamination Maximum content as | per DIN EN |
| 12021:20142Air quality by | 25 BAUERH | O 10 water |
| mg /m³ | 5 ≤mg/m³ | CO carbon monoxide1 |
| ppm2 (v) | 500 Depends oncartridge | CO carbon dioxide ppm 2 |
| (v) Depends on | 0.5 intakeair | Oil 0.1 oilmg |
1 /m³≤mg /m³Only use Baohua's special filter with carbon monoxide removal and oxidation in the intake air
2 Carbon content not exceeding 25ppm So the content of carbon monoxide in pure compressed air should not exceed5ppmThe carbon dioxide content in the intake air shall not exceed
|
|
|
| DIN EN 12021:2014 rule Defined scope | Operating200 pressure (Standard)300 |
| Work pressure (standard) PN or PN | 330 Operating |
| pressure max Maximum work pressure | bar Pressure dewpoint pressure dew point 3 < -20°C, equivalent 300 to |
| mg /m³ | at bar Piping connectionsPipeline interface G 1/4“ ( |
| condensate drain G | 0.57 1/8“) |
| Filterhousing volumeFilter bucket volume lDGRL2014/68/ | EU( PED. 3 |
| ) Art . 4 / ParProcessable air capacity Air handling capacity(at ambient 300 temperature20°1 C20and bar )300ambient temperature ℃ |
130 , |
1 work pressure bar time m³When using Baohua P21/350The situation without carbon monoxide remover.
| If using a filter cartridge with carbon monoxide remover, air treatment Decrease in quantity by approximately 4% | |
| . How to translate | 200 |
| inflatable device PN200 Filling | 200 device |
|
inflatable devicePN | Nominal pressure (PN) work pressure bar Valve design valve design1 filling valve withintegrated ventilation, with German cylinder connector G 5/8' 477 according toDIN EN200 144-2 and DIN andmanometer , 200 PN |
| Inflatable valve with venting function, European standard interface G 5/8' DIN | 1 477, PN pressure valve Filling hoseinflatable tube 1 Uniam highpressure 1 filling |
| hose, m | length high-pressure gas-filled tube Meter length |
International cylinder co nnector International adapter
1 international cylinder
connector
International adapter
How to translateinflatable devicePN300 The high-quality high-pressure inflation tube is made of food grade durable pipe material, which is easy to operate flexibly and safely. The rotatable tube valve connection design enables the inflation valve to operate quicklyEasy and safe connection to breathing gas cylindersInternational adapter
inflation valvePN200( black
| ) And the inflation valve PN300( | red 200 |
| ) How to translate | 200 |
|
Additional inflation device PN200 | Filling Device inflatable devicePN Nominal pressure (PN)work pressure bar Valve type Valve type 1 filling valve with integrated airbleeder, with German cylinder 477 connector G5/8' according200 to DIN EN144-2 and 200 DIN |
| and manometer , | 1 PN Inflatable valve with venting function, European standard interface G 5/8' DIN 477,PN 1 pressure valve Fillinghose 1 inflatable tube |
| Uniamhigh pressure | filling hose , |
mlength high-pressure gas-filled tube
| Meter length International cylinder co nnector | International adapter 300 |
| 1 international cylinder connector International adapter | 300 |
|
How to translate | Additional inflation device PN300 FillingDevice inflatable device PNNominal pressure (PN) work pressure bar Valve type Valve type1 filling valve with integrated air 477bleeder, with German cylinderconnector G300 5/8' according toDIN EN 300 144-2 |
| and DIN and | 1 manometer , PN Inflatable valve with venting function, European standard interface G 5/8'DIN 1 477, PNpressure valve 1 Filling |
![]()
hose inflatable tube Uniamhighpressure
filling 200hose , 300m length high-pressure gas-filled tube
Meter length
How to translate
PN 300/ PN 200 15 Inflatable conversiondevice
The inflation conversion device can achieve
bar and
bar
Inflation of gas cylinders. To limit the maximum working pressure, there are two pressure ranges Each of them is equipped with a tested final pressure safety valve.
Conversion device
| How to translate | Automatic condensate discharge and automatic shutdown function of gasoline driven air compressor The automatic condensate discharge system automatically discharges the condensate from the intermediate stage oil-water separator and the final stage oil-water separatorEmissions, set |
| During standby operation, every Discharge once per minute, automatically when stopped | Let it go. |
| include ■ | A pressure switch(Two pressure switches are included when ordering the conversion device) |
| ■ A condensate valve | ■A solenoid valve Automatic condensate drain system |
| Automatic condensate discharge system JUNIOR II -BPrincipleprinciple | 15 Cascade Version |
| version 2- | fold Control voltage control voltage24-48V |
DC Interval circuit(close /
open)Interval period (off) / 15 Open)min /
6 sec
Solenoid valvesolenoid valve Normally open 60204 (NO )
How to translate
Automatic condensate discharge and automatic shutdown of motor-driven air compressor
function The automatic condensate discharge system automatically discharges the condensate from the intermediate stage oil-water separator and the final stage oil-water separator
Release, equipmentDuring runtime, every
Discharge once per minute, automatically when stopped Let it go. include ■
| satisfy DIN | EN Required control(conform toCE Standard)■ |
| A pressure switch (Two pressure switches are included when ordering the conversion device) | ■ |
| A condensate valve ■ | A solenoid valveEquipped with an automatic condensate discharge system and control |
| Box making JUNIOR | 24 II-E Automatic condensate drain system |
| Automatic condensate discharge system JUNIOR II -E,JUNIORII | 15 -W 6 Principle |
| principle Cascade | Version version 2-foldControl voltage |
| control voltage V | AC Interval circuit(close / | open) Interval period (off)/ |
| Open) min / | 2.2 s | |
| Solenoid valve solenoid valve | Normally | open ( 240 NO |
| ) Compressor Control | 24 compressor control JUNIOR | |
| II -E | JUNIOR II | |
| -W Power | power | |
| kW Operating voltage | operating voltage | |
| 380-440 V220 / 230 | /V Control voltage | |
control voltageV
AC
Frequency
frequency50/60
HzVersion version Semi-automatic Controls control On/off-switch
Standard scope of supply
Standard Supply ScopeTimer for automatic condensate drain system, rotation monitoring
How to translate stainless steel frame Optional stainless steel main frame and support frameEquipped with a stainless steel frame
How to translate Trolley
For maximum flexibility, you can place the compressor on a small wheel, or you canRemove it for operation. Turning the handle on the handcart can ensure safety