Welcome Customer !

Membership

Help

Dongguan Hengzhun Standard Metrology Research Institute Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Dongguan Hengzhun Standard Metrology Research Institute Co., Ltd

  • E-mail

  • Phone

  • Address

    Huaheng Technology Building, Dongxing West Road, Dongkeng Town, Dongguan City

Contact Now

Standard reference materials for sulfide analysis in soil

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The applicable standard for sulfide analysis reference materials in soil is HJ 1459-2026 $r $n, and the determination method is the iodometric method according to standard HJ 1459-2026

Product Details

Standard reference materials for sulfide analysis in soilThis standard substance is applicable tosoilin the environmentsulfideThe research and monitoring of methods are of great significance and can be used for precision evaluation, instrument calibration, and quality control in related analytical testing in fields such as agriculture, geology, environmental protection, and health.

Onesample preparation

Selection of this standard substance含硫化物Soil is the matrix,exceptRemove impuritiesGrinding and high-speed mixingWait for special homogenization methods, after dryingDivide the samples into clean room packagespolyethylenein the bottle, throughCo60Radiation sterilizationStore away from light.

IICharacteristic values and uncertainties

number

substancename

Standard value(mg/kg

Expand uncertainty(mg/kg

RMH-A918

sulfide

15.2

1.8

The uncertainty assessment of the characteristic values of this standard substance mainly considersThe uncertainty components introduced by the joint calibration of multiple laboratories, as well as the uncertainty components introduced by the uniformity and stability tests of standard materials.

IIIUniformity testing and stability assessment

Refer to national standard materialsrelatedTechnical specification requirements,Combining standardsHJ 1459-2026 Soil and sediment Determination of sulfides Iodometric methodHow to translateRandomly select standard substance samples after packaging, and use20Iodometric methodConduct uniformity and stability tests, with a minimum sampling size of2g

The results indicate that the series of standard materials have good uniformity and stability. The validity period of this standard substance is from the date of self determinationYear. The research and development unit will continue to track and test the stability of the standard substance. If any changes in the value are found within the validity period, the user will be notified in a timely manner.

4Traceability and value determination methodsThis standard substance uses multiple methodshomeAssign values through laboratory joint calibration method.The fixed value method is standardHJ 1459-2026ofIodometric method

By using measurement methods and instruments that meet the requirements of metrological characteristics, the traceability of characteristic values of standard substances is ensured.

fivePackaging, storage, and useStandard reference materials for sulfide analysis in soilThis standard substance is based onpolyethylene20bottleEncapsulation, per bottle6gbottle/20Set.Store in a dark, clean, and room temperature place; Strictly prevent contamination during opening and use. The minimum sampling size is specified asgSingle-use Please do not use below this sampling amount.Due to the significant impact of temperature and other environmental conditions on sulfides, as well as inconsistent laboratory conditions, please use them as soon as possible.This standard substance is a hazardous substance and should be used with cautiondo wellprotection