Product Introduction:
-Chromatic aberration measurement
-Color density measurement: color density, overlay printing, dot enlargement, etc
-Unique spot color density function: directly measure spot color density, suitable for precise control of spot color density
-Ideal Match: Directly tell you how to reduce color difference by changing the ink layer thickness or ink concentration
-Connecting to a computer: easily achieve statistical analysis of measurement data
-Graphic interface: Chinese menu, easy to operate
-Suitable for packaging and commercial printing
detailed description:
Simple and precise method for measuring chromaticity and density
Spot color detection cannot use a general color density meter, but a spectrophotometer with chromatic function should be used. Because traditional density meters use color filters for sampling, they can only take four segments (corresponding to the four colors C, M, Y, and K) in the spectrum, while spectrophotometers take full spectrum samples, allowing for measurement of spot colors.
Gretag Macbeth's SpectroYeeTM combines accurate measurement results, unparalleled ergonomic applications, and user friendliness to set a new standard for color measurement technology in the printing industry. This portable spectrophotometer provides all the chromaticity measurement functions required for precise measurement and control of spot colors, as well as quick and easy monitoring of color density measurement during the printing process.
Measurement function (☆ standard function, □ optional function)
☆ Color density □ Average grayscale of all color densities □ Color density difference □ All color density differences
☆ Dot enlargement □ Printing characteristic curve ☆ Dot area □ Plate measurement
□ Contrast ☆ Overprint □ Hue Error/Grayscale □ Automatic Function 1/Automatic Function 2
☆ Spot color density ☆ Better matching ☆ Wet ink filter □ Without wet ink filter
□ Set password protection ☆ Automatic color detection ☆ Dual directional display ☆ Display brightness adjustment
☆ Standard color and blackness ordinary filters ☆ Telescopic measuring head ☆ Printer/computer interface
☆ Print measurement data with date and time ☆ Circular lens system ☆ Storage of 32 reference data
☆ User guide that can be gradually accessed using the control ball ☆ Data interface RS232C
Technical Specifications:
Lighting types D50, D65, A, C, D30~D300, F1~F12, customizable
Standard observation angle 2 °, , 10°
Spectral range: 380nm to 730nm
Optical system 45 °/0 ° in accordance with standard DIN5033
色度 CIELab CIELCH(ab) ΔE ﹡ CIELAB
Light source inflatable tungsten filament lamp, A-type lighting
Measurement range DIN16536 Density 0.0D~2.5D
The difference between instrument tables is 0.3 Δ E * CIELAB, or 0.15 Δ ECMC (2:1)
Measure 12 BCRA color plates (D50, 2 °)
Density repeatability DIN16536 standard density (repeatability ± 0.01D)
Without wet ink filter 0.0D~2.5D, yellow 0.0D~2.0D
Wet ink filter 0.0D~2.2D, yellow 0.0D~1.8D
Serial data interface RS232C for data exchange at baud rates ranging from 300 to 57600
Power supply nickel hydrogen battery, rated at 7.2 volts, 1300mAh
AC adaptation requirements 85VAC~270VAC, 47Hz~63Hz
Automatic detection and display of charging status
The charging time is about 3 hours, and it will automatically disconnect after being fully charged
Charging once takes about 3000 usage times
Weight approximately 990 grams (2.18 pounds)
Volume 8.3 × 8.0 × 24.5 centimeters (3.3 × 3.2 × 9.6 inches)
The parameters are for reference only and depend on the specific functions of the product.
Related solutions:
Spot color scheme
Scheme Type: Spot Color Scheme SpectroEye Scheme Introduction:
Spot color detection cannot use a general color density meter, but a spectrophotometer with chromatic function should be used. Because traditional density meters use color filters for sampling, they can only take four segments (corresponding to the four colors C, M, Y, and K) in the spectrum, while spectrophotometers take full spectrum samples, allowing for measurement of spot colors.
detailed description:
Spot color detection cannot use a general color density meter, but a spectrophotometer with chromatic function should be used. Because traditional density meters use color filters for sampling, they can only take four segments (corresponding to the four colors C, M, Y, and K) in the spectrum, while spectrophotometers take full spectrum samples, allowing for measurement of spot colors.
Gretag Macbeth's SpectroYeeTM combines accurate measurement results, unparalleled ergonomic applications, and user friendliness to set a new standard for color measurement technology in the printing industry. This portable spectrophotometer provides all the chromaticity measurement functions required for precise measurement and control of spot colors, as well as quick and easy monitoring of color density measurement during the printing process.
Spot color density: SpectroEye is the first device capable of measuring spot color density, allowing for comprehensive analysis of spot colors with a single measurement.
Better spot color matching: Before returning to the laboratory to reconfigure colors, let SpectroEye use its "Better Match" function to help you quickly determine whether simply changing the ink layer thickness can improve the printing surface.