Welcome Customer !

Membership

Help

Changzhou Jintan Jingda Instrument Manufacturing Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Changzhou Jintan Jingda Instrument Manufacturing Co., Ltd

  • E-mail

    929644558@qq.com

  • Phone

    13915810870

  • Address

    Jintan Economic Development Zone, Jiangsu Province

Contact Now

Special oscillator for horizontal oscillation method

NegotiableUpdate on 01/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The main features of the horizontal oscillation method specific oscillator product are: $n1, independent research and development, production, and humanized slope design. Full digital display, complete functions, and easy operation. $n2、 Brushless motors have the characteristics of high load-bearing capacity, stable speed, long-term continuous and stable operation, and silent design. The LCD instrument panel has functions such as speed display, timed automatic alarm, and corresponding fault codes. $n4、 Made of stainless steel plate with high-temperature electrostatic spraying, the box is beautiful, easy to clean, corrosion-resistant, and durable. $n5、 2LPE bottles, glass bottles, and TFLON bottles can be placed simultaneously.
Product Details
1Special oscillator for horizontal oscillation methodMain features of the product:

1. Independent research and development, production, and humanized slope design. Full digital display, complete functions, and easy operation.

2. Brushless motors have the characteristics of high load-bearing capacity, stable speed, long-term continuous and stable operation, and silent design.

3. The LCD instrument panel has functions such as speed display, timed automatic alarm, and corresponding fault codes.

4. Made of stainless steel plate with high-temperature electrostatic spraying, the box is beautiful, easy to clean, corrosion-resistant, and durable.

5. 2LPE bottles, glass bottles, and TFLON bottles can be placed simultaneously.

6. Suitable for oscillation leaching of environmental water samples, soil samples, and solid waste, and in compliance with the Solid Waste Leaching Toxicity Leaching Equipment (HJ557-2010).

2、 Product Introduction:

The JDWZ series horizontal oscillator is designed specifically for the oscillation leaching of environment, water samples, soil samples, and solid waste. The product complies with the toxicity leaching equipment for solid waste leaching and can meet the technical requirements of the horizontal oscillation method. The horizontal oscillation method requires an oscillation frequency of (110 ± 10) times/min, an amplitude of 40mm, oscillation at room temperature for 8 hours, and standing for 6 hours. After filtration through a 0.45 μ m filter membrane, the concentration of pollutants is measured. 】When solid waste containing harmful substances is piled up or disposed of, it may leach into water, causing the harmful substances to migrate and transform, polluting the environment. Using a horizontal oscillator for leaching experiments is a field or experimental simulation of this natural process. When the amount of harmful substances leached exceeds the threshold set by relevant regulations, the waste has leaching toxicity. The identification of leaching toxicity of solid waste is the basis for determining hazardous waste and an important link in the development of solid waste management and disposal technologies.

2、 Application areas of JDWZ series horizontal oscillator products:

1. Solid waste treatment field: Solid waste treatment stations, environmental analysis, university research and other laboratory institutions.

2. Agricultural and forestry research and development field: laboratories of institutions such as the Academy of Agricultural Sciences, forestry departments, and agricultural departments.

3. In the field of food and drug: laboratories of quality inspection departments, customs, hazardous waste treatment stations and other institutions.

4、 Technical parameters of the oscillator product for horizontal oscillation method:

Product Model JDWZ-W04 JDWZ-W06 JDWZ-W08 JDWZ-W010
Number of sample bottles 4a 6a 8a 10a
Sample bottle capacity 2L(Delivery)
Shell material All for304Stainless steel with electrostatic spraying
rated power 80W 100W 120W 140W
oscillation frequency 0-280time/min(adjustable)
drive motor Silent brushless DC motor
display mode LCDLCD (Liquid Crystal Display)
Timing 0-999Hour (or normally open)
Oscillation amplitude 40mm
working hours continuous

5、 Product Instructions:

1. The instrument should be placed on a flat and firm ground with a coefficient of friction (such as cement ground), and the ground should be flat and not slip. If the ground is smooth, please place an anti friction rubber pad on it. In addition, it is necessary to ensure that the four machine heels of the instrument are in contact with the ground to avoid deviation and slipping during high-speed operation of the instrument.

2. The environment where the instrument is placed should be clean and tidy, with moderate temperature and good ventilation.

3. To ensure good balance performance of the instrument during operation and avoid significant vibration, all test bottle positions should be filled when bottling, and the culture solution in each bottle should be roughly equal. If there are not enough culture bottles, the test bottles can be symmetrically placed or filled with other equal amounts of solution to fill the empty spaces.

4. After the container is installed, turn on the power and turn on the power switch. Set working parameters (working time, working speed, etc.). For specific operating instructions, please refer to the "User Manual for Brushless Motor Controller" (attached separately with the manual).

5. Regarding speed control: When starting, the speed should be gradually increased from small to large, and should not be set too fast all at once. To extend the service life of the machine, it is recommended to use it at a medium speed within 200rpm (using it at a medium speed within the speed range can extend the service life of the instrument). If there is constant speed oscillation, the setting of oscillation speed and time (using a constant speed controller, displaying speed in the upper row and time in the lower row) is:

1) First, turn on the oscillation switch (green key) on the machine. At this time, the speed control table will display a number of 100, indicating that the initial set speed is 100rpm (the set value at the factory or the value required by the user). Press the "Speed" button to set the speed, then press the "RUN" button to start. The machine will slowly start to the set speed within approximately 30 seconds. If you want to set 200rpm, you can press the "" key until the speed display shows 200rpm.

2) If you need to stop the local machine during operation, simply press the STOP button, and then press the RUN button again when restarting.

3) Timer setting: Press the H (hour) key to set the hour, and press the M (minute) key to set the minute. If you want to set a timer for 1 hour and 30 minutes, simply press the H key to 1 and then press the M key to 30. To set the machine to normally open, set both H and M to 0. The duration of this speed controller Z is 9999 minutes.

The above settings are for reference only, please refer to the attached "Speed Controller Manual" for details.

6. Before each shutdown, all control switches should be in a non working state and the power should be cut off.

7. Before stopping the machine after work is completed, all switches should be placed in a non working state, and then the power should be cut off.

6、 Attention:

1. Electrical safety precautions: A. The electrical rated parameters of the socket provided by the user should not be less than the electrical rated parameters of the machine, and there should be good grounding measures. B. Before connecting the power supply, please confirm whether the voltage of the socket matches that of this device. C. The power socket connected to this device should be an independent power socket. D. When unplugging from a power outlet, do not directly drag the power cord. E. When there are the following situations, the power must be cut off: (when replacing fuses, when equipment malfunctions and cannot work properly, when equipment stops working for a long time.)

2. The whole machine is strictly prohibited from being used in an environment with direct sunlight.

3. Speed regulation should start slowly from low speed to high speed and be used within the speed range, which can extend the lifespan of the machine.

4. The machine may experience some displacement during high-speed oscillation, so it should be monitored by someone during use.

5. It is strictly prohibited to move the machine during normal operation

6. It is strictly prohibited for objects to collide with the machine.

7. Children are strictly prohibited from approaching the machine to prevent accidents.

8. Before replacing the fuse, the power should be cut off first.

9. After use, please clean the machine without leaving any water droplets or dirt residue.