Welcome Customer !

Membership

Help

Shanghai Bassen Industrial Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Bassen Industrial Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    Xiaokunshan

Contact Now

Siemens circuit board C-A5E33541972 power supply agent

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Siemens circuit board C-A5E33541972 power agent $r $n CNC system: SINUMERIK and SIMODRIVE611 series modules, servo motors, spindle motors Order number: 1PH/1FT/1FK/6SN/6FC/6FM/6FX/6SL/Siemens PLC S7-300 S7-200 S7-400 S7-1200 S7-1500 ET200 S SP frequency converter V series MM series 6SE70 discontinued

Product Details

Siemens circuit board C-A5E33541972 power supply agentSiemens circuit board C-A5E33541972 power supply agent

SIRIUS 3RW30 basic performance soft starter is suitable for soft starting of three-phase asynchronous motors.

Due to the implementation of two-phase control, not only can the currents of all three phases be maintained throughout the entire starting process, but also the interfering DC component is eliminated. This not only enables the two-phase starting of the motor to reach up to 55 kW (at 400 V), but also avoids the current and torque peaks generated by using wye delta starters.

application

3RW30 soft starter can be used for soft starting of three-phase asynchronous motors.

Due to two-phase control, the current remains constant in each phase throughout the entire start-up time. Due to the influence of continuous voltage, unavoidable phenomena such as peak current and torque under star delta starter conditions will not occur in this situation.

The 3RW solid-state motor controller is designed for easy starting conditions. In case of abnormal conditions or increased switching frequency, it may be necessary to choose a larger device.

If the starting time is long, it is necessary to use overload relays for heavier starting loads. Recommend using PTC sensors

It is not allowed to use capacitive components between SIRIUS 3RW soft starter and motor in the motor feeder line (e.g. reactive power compensation equipment cannot be used). In addition, both static systems used for reactive power compensation and dynamic PFC (power factor correction) cannot be operated in parallel during startup and soft starter ramp down. This is crucial for preventing compensation equipment and/or soft starters from malfunctioning.

All components of the main circuit, such as fuses, switchgear, and overload relays, should be selected according to the corresponding requirements for direct starting during short-circuit loading. Fuses, switchgear, and overload relays are ordered separately. Please follow the switching frequency specified in the technical data.

Siemens S120 power module, Siemens S120 agent, Siemens inverter agent, basic power module is suitable for applications without power feedback to the grid, or applications where the exchange between the motor shaft and the generator shaft is carried out in the DC bus. The basic power module can only feed electrical energy from the grid into the DC bus and cannot provide reverse feedback. The DC bus voltage is directly generated from the 3-phase incoming line voltage through a 6-pulse bridge circuit. The basic power module is suitable for grounded star TN/TT systems and ungrounded symmetrical IT systems. The connected motor modules are pre charged by integrated pre charging resistors (20 kW and 40 kW) or by thyristors (100 kW). The 20 kW and 40 kW basic power modules integrate a braking module. After adding an external braking resistor, the basic power module can be directly used for applications with intermittent braking mode, such as parking. In addition to the external braking resistor, the 100 kW basic power module also requires a braking module to brake. The book type basic power module comes standard with the following connections and interfaces:

• 1 power connection

One 24V DC switching power supply interface

• 1 DC bus interface

3 DRIVE CLiQ sockets

• 1 brake resistor interface (only for 20 kW and 40 kW basic power modules)

1 temperature sensor input

The status of the basic power module is displayed through two multi-color LEDs.

The supply scope of the basic power module includes:

DRIVE CLiQ cable, used to connect adjacent controllers located on the left side and responsible for drive control

Unit, length 0.11 m (4.33 in)

DRIVE CLiQ cable (length depends on module width), used to connect BLM and phase

Adjacent motor module, cable length=BLM width+0.11 m (4.33 in)

• Short circuiting device, connecting the 24 V DC bus to adjacent motor modules

24 V terminal adapter (X24)

Connector X21

Two mute plugs for sealing unused DRIVE CLiQ sockets

1 set of warning labels in 30 languages

1 heat sink (only applicable to basic power modules cooled by cooling plates)

The basic power module is suitable for applications where there is no electricity feedback to the grid, or for applications where the exchange between the motor shaft and the generator shaft is carried out in the DC bus. Pre charge the connected motor module through thyristor control. Thyristors always trigger with a delay angle of 0 °. The basic power module is suitable for grounded TN/TT systems and ungrounded IT systems. In the basic power module of the device type, brake modules of corresponding sizes can be installed and used in conjunction with external brake resistors to support the power generation mode of the drive system.

The device type basic power module comes standard with the following connections and interfaces: • 1 power connection

One 24V DC switching power supply interface

1 DC bus interface (DCP, DCN) for supplying power to connected motor modules

1 DC bus interface (DCPA, DCNA) for connecting the brake module

1 temperature sensor input (KTY84-130 or PTC/Pt100)

3 DRIVE CLiQ sockets

The status of the basic power module is displayed through two multi-color LEDs.

The supply scope of the basic power module includes:

0.6 m (1.97 ft) DRIVE CLiQ cable for connecting CU320-2 or SIMOTION D4x5-2 control units or CX32-2 expansion controllers

A 1.45 m (4.76 ft) long DRIVE CLiQ cable is used to connect the control unit and motor modules

The basic power module communicates with the higher-level control unit through DRIVE CLiQ. The higher-level control unit can be CU320-2 or SIMOTION D control unit. Running the basic power module requires