-
E-mail
sales@scienhome.com
-
Phone
15022775827
-
Address
Unit D, 4th Floor, Building G, No. 16 Rongyuan Road, Huayuan Industrial Zone, Tianjin
Tianjin Chenhang Science and Technology Development Co., Ltd
sales@scienhome.com
15022775827
Unit D, 4th Floor, Building G, No. 16 Rongyuan Road, Huayuan Industrial Zone, Tianjin
shodex KW-803Analysis of human serum albumin oligomers
shodex KW-803Analysis of human serum albumin oligomers
ShodexThe brand has hundreds of different separation types of chromatography columns applied in various fields. Featured products: Polymer matrix size exclusion chromatography columnHILICChromatography columns and sugar analysis chromatography columns have been welcomed and recognized by chromatography professionals.Applied in different scientific fields such as environmental protection, petrochemicals, life sciences, food, and agriculture.
Our company represents Conno(COMETRO)He Showa(SHODEX)Brand's products and distributionELDEX,TELEDYNE SSI,IDEX,VICI,SGE,HAMILTONBrand's products.
Self operated products:ScienhomeLiquid chromatography column(P/N:91182545)TheScienhomeProtect the core of the column(P/N:612111)TheScienhomeProtective column component(P/N:600220)Other chromatographic matching products such as chromatographic column constant temperature column box, needle filter, microporous membrane, etc.
Pharmacopoeia2020According to the fourth part of the regulation, the use of high-performance liquid chromatography to analyze human serum albumin oligomers requires a hydrophilic silica gel high-performance volume exclusion chromatography column(SEC, Limit of Resistance300 kD, granularity10 μm), column diameter7.5 mm,long60 cm(Note)1). The pharmacopoeia requires that the separation degree between the monomer peak and dimer peak of human serum albumin should be greater than1.5The tailing factor should be calculated based on the peak of human serum albumin monomer0.95-1.40. UsePROTEIN KW-803Chromatographic column analysis can meet the requirements of various pharmacopoeias-Such requirements.
note1Pharmacopoeia2020According to the regulations, the inner diameter and length of the chromatographic column, the shape, particle size and particle size distribution of the filler, pore size, surface area, surface coverage of bonding groups, residual amount of surface groups on the carrier, and the density and uniformity of the filling all affect the performance of the chromatographic column. The appropriate chromatographic column should be selected based on the properties of the separated substance.
(Standard column)
Order Number |
Product Name |
particle size(μm) |
Specifications(mm)inner diameterxlong |
F6989103 |
PROTEIN KW-803 |
5 |
8.0×300 |
F6700131 |
PROTEIN KW-G 6B |
7 |
6.0×50 |