E-mail
sales@scienhome.com
-
Phone
15022775827
-
Address
Unit D, 4th Floor, Building G, No. 16 Rongyuan Road, Huayuan Industrial Zone, Tianjin
Tianjin Chenhang Science and Technology Development Co., Ltd
sales@scienhome.com
15022775827
Unit D, 4th Floor, Building G, No. 16 Rongyuan Road, Huayuan Industrial Zone, Tianjin
Kangnuo pesticide residue detection post column derivative instrument6000PCR
Kangnuo pesticide residue detection post column derivative instrument6000PCR
Conno(CoMetro)6000Characteristics of Series Post Column Derivative System (Post Column Derivative Device):
Ø Fast and easy to set up
Connect an inlet from the chromatographic column and an outlet into the detector, and the installation is complete.
Ø Modular design
Optional single or dual reaction cores. The two-step reaction process of simultaneous heating reaction and room temperature reaction can be carried out.
optional1Taiwan2One or more derivative agent pumps.
Ø Reduced joint and pipeline connections to prevent leakage.
Ø All connection joints are located on the front panel for user convenience.
Ø Panel display, convenient for setting up
The front panel of the reactor displays the set temperature and actual temperature of each reaction core.
The front panel of the derivative pump displays the flow rate, pressure, and pressure limit of each reagent.
Ø external control
The flow rate of the pump and the temperature of the reactor can be controlled through the front panel or throughRS232Implement external control.
Ø Modular reactor, only requires2A connector can replace the reactor core.
Ø The designed reaction core reduces peak diffusion.
Ø System widePEEKFlow path.
Conno(CoMetro)6000Series post column derivative system (post column derivative device)Reactor characteristics:
Continuous reaction loop, sealed Multi directional flow achieves mixing
Front panel digital control: temperature setting Temperature Display Ready Display
Heating core |
|
Reactor volume |
0.15/0.5/1.5ml(Optional) |
Reaction volume accuracy |
±5% |
Temperature control range |
room temperature+10℃--150℃ |
Temperature reproducibility |
±0.4℃ |
Temperature accuracy |
±1℃ |
Safe temperature cut-off point |
160℃ |
stabilization time |
150℃ 30Ready displayed within minutes |
input |
Front panel orRS232 |
Derivative pump characteristic parameters:
Automatic online self-cleaning, extending the service life of the sealing ring
Built in exhaust valve design(PEEK)
Built in pressure sensor
Stepper motor drive, fast electronic filling
Numerical keyboard display: flow rate setting, pressure setting, and pressure setting/lower limit
flow velocity |
0.001-10ml/min |
pressure |
0-4000PSI |
Flow path |
completePEEKFlow system |
Flow crystallinity |
0.2%RSD |
Flow accuracy |
±1% |
input |
passRS232Implement remote control and monitoring through the interface |