Shanghai Thunder Magnetic Dissolved Oxygen AnalyzerJPSJ-605F type
Performance characteristics:
①Large screen dot matrix LCD display, intuitive and clear, comprehensive content (can display measurement values, temperature values, measurement modes, operation dates and times)
②Allow measurement of multiple parameters: dissolved oxygen concentration value, dissolved oxygen saturation value, current value, and temperature value
③Support zero oxygen and full-scale calibration,supportElectrode calibration reminder function; SupportAutomatic temperature compensation; Support pressure calibration and salinity calibration
④3Reading mode:“Fast, medium, strict, customizable'Multiple equilibrium conditions to choose from; Timed termination measurement and timed automatic interval measurement2Optional timed reading mode; Clearly grasp the continuous change process of the sample
⑤Support storage500 sets of measurement data, in compliance withGLPspecification;support dataofSearchDelete andprint
⑥supportUSBconnectPCSerial port printer; Allow printing and outputting measurement results
⑦Equipped with power-off protection function, data will not be lost after power-off
⑧Support firmware upgrade
Technical Specifications:
|
model Technical Specifications |
JPSJ-605F |
|
accuracy class |
± 0.30 mg/L (indication error) |
|
measurement range |
dissolved oxygen |
(0.00~45.00)mg/L |
Dissolved oxygen saturation |
(0.0~300.0)% |
|
temperature |
(-5.0~110.0)℃ |
|
resolution |
dissolved oxygen |
0.01mg/L |
Dissolved oxygen saturation |
0.1% |
|
temperature |
0.1℃ |
|
basic error |
dissolved oxygen |
±0.10mg/L |
Dissolved oxygen saturation |
±2.0% |
|
temperature |
±0.2℃ |
|
Atmospheric pressure compensation |
Manual (60.0~110.0) kPa |
|
salinity compensation |
Manual (0.0~40.0) g/L |
|
temperature compensation |
Automatic (0.0~40.0) ℃ |
|
power supply |
DC universal power supply (9VDC, 500mA, positive inside and negative outside) |
|
Standard electrode configuration |
DO-958-S type dissolved oxygen electrode |
|
Standard electrode matching measurement range |
(0.00~20.00)mg/L |
|
Application fields:
Shanghai Thunder Magnetic Dissolved Oxygen AnalyzerJPSJ-605F typeIt is a large screen dot matrix LCD display, intuitive and clear, comprehensive dissolved oxygen analyzer, mainly used for monitoring tap water sources, aquaculture farms, environmental protection, sewage treatment plants, beverage industry, and scientific research units to determine the dissolved oxygen content or concentration of water bodies.