Welcome Customer !

Membership

Help

Jiangsu Kangjian Medical Supplies Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Jiangsu Kangjian Medical Supplies Co., Ltd

  • E-mail

    info@china-kangjian.com

  • Phone

  • Address

    No. 16, Zhanqian Road, Railway Station, Jiangyan District, Taizhou City, Jiangsu Province

Contact Now

Separation glue coagulation tube

NegotiableUpdate on 08/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Model: Separation gel+coagulant Product brand: Kangjian Medical KANGJIAN Catalog number: 0101-0000 Product material: PET or glass Remarks: 1. Customizable labels; 2. Customizable sterile products; 3. Please indicate the product number in the ordering basket.

Product Details

Product overview

  • Used for serum biochemistry, immunology, drug testing, etc., uniformly coating coagulants on the inner wall can shorten blood clotting time. Due to the pure nature of the imported separation gel from Japan, its physical and chemical properties are stable, and it has strong resistance to high temperatures and radiation, effectively avoiding the decomposition and denaturation of the separation gel during storage and transportation. After centrifugation, the separation gel flips and solidifies to form a barrier, separating serum from blood cells, effectively preventing substance exchange between the two, obtaining high-quality serum, making the test results more accurate, and improving the collection rate of serum. The serum remains stable for more than 48 hours without significant changes in its biochemical properties and chemical composition, and can be directly loaded onto the machine.

  • The complete contraction time of the blood clot is 20-25 minutes, the centrifugation speed is 3500-4000 revolutions per minute, the centrifugation time is 5 minutes, and the recommended storage temperature is 4 ℃ -25 ℃.

Characteristics and advantages

① Safety helmet

◎ Using high-quality synthetic butyl rubber plugs, it is very suitable for puncture sampling in fully automatic analyzers. It has good air tightness, low puncture force, less debris, no hole blockage, and no needle bounce.

The specially designed rubber stopper configuration reduces the wear and tear of the puncture injection needle, and the lifespan of the puncture needle is more than twice that of using ordinary rubber stoppers.

The butyl rubber plug fits tightly with the safety helmet, without flipping or separating, making it easy and pleasant to open and close the helmet body.

Suitable for the use of various de capped centrifuges and cap opening machines.

The color of the skull meets internationally recognized standards.

② High quality pipes

Using high-quality PET material, with stable properties and good airtightness.

The inner wall of the PET tube is treated with silicification, resulting in a smooth surface and avoiding cell adhesion.

The inner wall is treated with biomimetic membrane technology, providing a comprehensive and detailed protection plan for blood cells.

③ Water separation gel, coagulant

Choosing to use coagulants and serum separation gels produced by Mizuki Chemical Industry Co., Ltd. in Japan can make serum samples more authentic and test results more accurate.

◎ Using high-quality inert separation gel to prevent unreasonable interference with blood.

After rapid centrifugation, clear, transparent and clean serum samples can be obtained.

◎ High temperature resistance (45 ℃) and convenient freezing storage, with stable properties, rarely experiencing the phenomenon of "oil droplets" after centrifugation.

Radiation sterilization.

④ Customized labels

According to different customer requirements, different materials and labels with specific identification can be customized. Printing prefabricated barcodes is easy to recognize and more durable.

The detachable label tube and barcode label tube are pre labeled with customized labels before leaving the factory.

Specification parameters

catalog number Original Number Tube bodyspecifications

Tube material

blood capacity taken additive Support/Plate Branch/box Remark
0101-0211 KJ020AS Ø13×75 glass 2ml Separation gel+coagulant 100 1800

Immediately shake lightly after blood collectionfall

Mix 6-8 times and then let it stand

Centrifuge after 30 minutes.

0101-0212 KJ020AS Ø13×75 PET 2ml Separation gel+coagulant 100 1800
0101-0311 KJ030AS Ø13×75 glass 3ml Separation gel+coagulant 100 1800
0101-0312 KJ030AS Ø13×75 PET 3ml Separation gel+coagulant 100 1800
0101-0411 KJ040AS Ø13×75 glass 4ml Separation gel+coagulant 100 1800
0101-0412 KJ040AS Ø13×75 PET 4ml Separation gel+coagulant 100 1800
0101-0321 KJ0301AS Ø13×100 glass 3ml Separation gel+coagulant 100 1200
0101-0322 KJ0301AS Ø13×100 PET 3ml Separation gel+coagulant 100 1800
0101-0421 KJ0401AS Ø13×100 glass 4ml Separation gel+coagulant 100 1200
0101-0422 KJ0401AS Ø13×100 PET 4ml Separation gel+coagulant 100 1800
0101-0521 KJ0501AS Ø13×100 glass 5ml Separation gel+coagulant 100 1200
0101-0522 KJ0501AS Ø13×100 PET 5ml Separation gel+coagulant 100 1800
0101-0621 KJ0601AS Ø13×100 glass 6ml Separation gel+coagulant 100 1200
0101-0622 KJ0601AS Ø13×100 PET 6ml Separation gel+coagulant 100 1800
0101-0931 KJ0901AS Ø16×100 glass 9ml Separation gel+coagulant 100 1200
0101-0932 KJ0901AS Ø16×100 PET 9ml Separation gel+coagulant 100 1200