1、 Overview of Self Operated Pressure Regulating Valve
ZZYP type self operated pressure regulating valve is a type of valve that does not require an external energy source. It uses the energy of the controlled medium itself as a power source, introduces it into the actuator chamber to generate thrust, and controls the movement of the throttling element to achieve automatic regulation. It has comprehensive functions of measurement, execution, and control. Can be used in places without gas or electricity. Widely used in the automatic control systems of various equipment gas, liquid, and steam media in the petroleum, chemical, power station, light industry, and printing and dyeing industries for deceleration pressure, stabilization (used for post valve pressure regulation), and automatic control of pressure relief and stabilization (used for pre valve pressure regulation). According to different working conditions of users, different types of valve core structures and actuators can be selected to achieve the desired control effect.
2、 Model of self operated pressure regulating valve
| category | model | category | model |
| Single seat pressure closed type | ZZYP-16~64B | Single seat pressure closed type | ZZYP-16-64K |
| Double seat pressure closed type | ZZYN-16~64B | Double seat pressure closed type | ZZYN-16~64K |
| Sleeve compression closed type | ZZYM-16~64B | Sleeve compression closed type | ZZYM-16~64K |
Pressure closed type: used for regulating the pressure behind the valve. When the pressure behind the valve increases, the valve closes to achieve the purpose of pressure reduction and stabilization.
Pressure open type: used for regulating the pressure behind the valve. When the pressure behind the valve increases, the valve opens to achieve the purpose of pressure relief and stabilization.
3、 Main technical parameters of self operated pressure regulating valve
| Nominal diameter DN (mm) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | |||
| Valve seat diameter DN (mm) | 10 | 12 | 15 | 20 | ||||||||||
| Rated flow coefficient Kv | 1.8 | 2.4 | 4.4 | 4 | 11 | 20 | 30 | 48 | 75 | 120 | 190 | 300 | 480 | 760 |
| Allowable pressure difference (MPa) | 2.5 | 2.0 | 1.6 | 1.0 | ||||||||||
| Nominal pressure (MPa) | 1.6 4.0 6.4 | |||||||||||||
| Inherent flow characteristics | Quick open | |||||||||||||
| Ensure the normal operation of the pressure regulating valve Minimum pressure difference P (MPa) |
0.05 | |||||||||||||
| Pressure segmentation range (KPa) | 15-50 40-80 60-100 80-140 120-80 160~220 200~260 240~300 280~350 330~400 380-450 430-500 480-560 540-620 600-700 680~800 780~900 800~1000 900~2000 |
|||||||||||||
| Working temperature ℃ | Liquid ≤ 140; Gas ≤ 80; Equipped with condenser and heat sink ≤ 350 | |||||||||||||
| Suitable for media | Gas, steam, low viscosity liquid | |||||||||||||
| Flange size and type | PN10、16、40GB9113-88、PN64JB/T7-94; PN10, 16 convex, PN40, 64 convex type Alternatively, other standard types of flanges (such as ANSI, JIS, DIN, etc.) can be selected according to user requirements |
|||||||||||||
| structural length | According to GB12221-89 standard | |||||||||||||
| Execution mechanism signal interface | Internal thread M16 × 1.5 | |||||||||||||
Note: The range of pressure segmentation can be designed according to user requirements.
4、 Main performance indicators of self operated pressure regulating valve
| Control accuracy% | ±8 | |||||||||||
| Allow leakage Leakage quantity |
Hard seal (L/H) | Single seat (Class IV): ≤ 10-4 Valve rated capacity: Double seat, socket (Class II), ≤ 5 × 10-3 × Valve rated capacity | ||||||||||
| Soft seal (ml/min) | DN(mm) | |||||||||||
| 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | ||
| 0.15 | 0.3 | 0.45 | 0.6 | 0.9 | 1.7 | 4.0 | 6.75 | |||||
5、 Self operated pressure regulating valve can be equipped with accessories
Condenser (used in situations where the medium is steam), heat sink, etc
6、 Dimensions and weight of self operated pressure regulating valve
| Nominal diameter (DN) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | ||
| L | PN16、40 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | |
| PN64 | 230 | 230 | 260 | 260 | 300 | 340 | 380 | 430 | 500 | 550 | 650 | ||
| B | 233 | 332 | 373 | 522 | 673 | 980 | 1200 | ||||||
| H | Pressure regulation range (MPa) |
15~140 | 475 | 520 | 540 | 710 | 780 | 840 | 880 | 915 | |||
| 120~300 | 455 | 500 | 520 | 690 | 760 | 800 | 870 | 880 | |||||
| 280~500 | 450 | 490 | 510 | 680 | 750 | 790 | 860 | 870 | |||||
| 480~1000 | 445 | 480 | 670 | 740 | 780 | 850 | 860 | ||||||
| 600~1500 | 445 | 570 | 600 | 820 | 890 | 950 | 950 | 1000 | |||||
| 1000~2500 | 445 | 570 | 600 | 820 | 890 | 950 | 950 | 1000 | |||||
| A | Pressure regulation range (MPa) |
15~140 | φ282 | φ308 | |||||||||
| 120~300 | φ232 | ||||||||||||
| 280~1000 | φ196 | φ196 | φ282 | ||||||||||
| 600~2500 | φ85 | φ96 | |||||||||||
| Approximately weight (Kg) | 26 | 37 | 42 | 72 | 90 | 114 | 130 | 144 | 180 | ||||