Second hand Shimadzu GC-14C gas chromatograph

NegotiableUpdate on 02/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Used Shimadzu GC-14C gas chromatograph: temperature range -90 ℃~420 ℃, supports multiple detectors (FID/TCD/ECD, etc.), precise carrier gas control, compatible with capillary columns and packed columns. Modular design can accommodate 3 injection and 4 detection units, widely used in the fields of petrochemicals, environmental monitoring, food safety, and pharmaceutical research and development, with high reproducibility and convenient operation.
Product Details

Second hand Shimadzu GC-14C gas chromatograph

1. Core performance parameters

Temperature control system

Column temperature box: standard configuration range: room temperature+10 ℃~420 ℃, low-temperature accessories extended to -90 ℃~420 ℃

Temperature accuracy: ± 1% (K-level), can be calibrated up to 0.01 ℃

Heating rate: 0.1~40 ℃/min (5-stage program heating), cooling rate: 420 ℃ to 50 ℃ takes 7-7.5 minutes (25 ℃ environment)

Gas control

Carrier gas pressure: 0-970 kPa, flow accuracy 0.01 mL/min

Support modes: constant pressure/constant flow rate/carrier gas constant linear velocity, suitable for capillary column and packed column

2. Key component configuration

Detector system

FID: Sensitivity 5 × 10 ⁻¹² g/s (biphenyl detection), dynamic range 10 ⁷

TCD: Constant current control, sensitivity of approximately 7000 mV · mL/mg

ECD: 63Ni radioactive source, sensitivity 0.2 pg/s (γ - BHC)

FPD: Sulfur mode 5 × 10 ⁻¹¹ g/s (sulfur in thiophene), phosphorus mode exclusive detection

injection system

Support split/no split injection, cold column head injection, and packed column injection

Injection port pressure: 0-970 kPa, total flow rate 0-1200 mL/min

Double filling injection unit (DINJ-2014): supports dual channel analysis, temperature control accuracy of 1 ℃

3. Hardware and Scalability

mechanical structure

Internal cavity of column temperature box: 231 × 361 × 163 mm

Main board size: 400 × 690 × 607 mm (length × height × width)

Weight: 48 kg (some configurations can reach up to 50 kg)

Power supply: AC 220V/1800VA/50Hz

intelligent system

Chinese LCD display (16 × 2 characters) real-time monitoring of temperature/time/chromatogram

Equipped with GCsolution Lite workstation, supporting GMP/GLP compliance and FDA 21 CFR Part 11 standards

Self checking function and regular maintenance reminders to prevent unexpected shutdowns

Modular design: up to 3 injection units and 4 detectors can be installed, supporting unit addition and expansion

4. Application areas and technological highlights

Typical Applications

Petrochemical industry: analysis of alkane/alkene/aromatic hydrocarbon components, product quality control

Environmental monitoring: detection of organochlorine pesticide residues (detection limit 0.1 ng/L) and polycyclic aromatic hydrocarbons

Food safety: pesticide residues (with a spiked recovery rate of 95-112%), quantitative analysis of additives

Pharmaceutical research and development: drug content determination, metabolite analysis

5. Second hand Shimadzu GC-14C gas chromatographMaintenance and operation

Daily maintenance: The injection port is cleaned daily, and the chromatographic column is flushed regularly (n-hexane/methanol)

Calibration cycle: Temperature/flow calibration every quarter, detector baseline stability verification every quarter

Operation training: Built in help function, beginners can quickly master parameter settings and troubleshooting