E-mail
info@maomo17.com
-
Phone
13472768389
-
Address
Room 2017, No. 298 Kangqiao East Road, Pudong New Area, Shanghai
Shanghai Maomo Scientific Instrument Co., Ltd
info@maomo17.com
13472768389
Room 2017, No. 298 Kangqiao East Road, Pudong New Area, Shanghai
Sea Energy T930 Fully Automatic Moisture Titimeterintroduction
The T930 fully automatic moisture titrator adopts the Karl Fischer titration method, which can be used to accurately analyze the moisture in solids and liquids with reliable results and a wide measurement range (0.001% -100%). Equipped with a 10 inch ultra large touch screen, easy to operate. Adopting multiple safety designs to avoid contact between operators and toxic reagents. It can be widely applied in fields such as petroleum, chemical, food, cosmetics, and pharmaceuticals.
Sea Energy T930 Fully Automatic Moisture Titimeterfeature
·Humanized human-computer interaction design, close to the daily use of mobile phones and tablets, easy to operate, flexible to click on parameters that need to be set and changed, and can slide left and right to view richer data content, improving work efficiency.
·Modular menu bar allows for quick and accurate access to various interfaces.
·In sample testing, real-time display of test curves, instrument parameters, analysis results, and other information allows for real-time monitoring of the entire titration process.
·Multiple result units are displayed: mg,%, ppm, H2O, mL, mg/mL, mg/g, etc.
·Equipped with data retrieval function, it can quickly access historical data.
·The V-T and E-T spectra can be switched between analysis experiments at any time, and the curves can be manually enlarged or reduced.
·8GB of massive storage space can be used to store experimental methods, data, traceability files, and other content.
·Equipped with a startup wizard and built-in software manual.
| Technical Indicators: | ||
![]() T930 fully automatic moisture titrator
|
![]() T931 Coulombic Moisture Analyzer
|
|
| Determination method | Karl Fischer Capacity Method | Karl Fischer Coulomb method |
| Moisture measurement range | 0.001%-100%水分 | |
| Recommended moisture measurement range | 0.1%-100%水分 | 10μgH2O~200mgH2O |
| Polarization current range | 1~24μA | |
| Polarization current resolution | 0.01μA | |
| Polarization current error range | 0.05μA | |
| voltage range | 0-1999mV | |
| Voltage resolution | 0.1mV | |
| Voltage error range | ±0.2mV | |
| Burette driver: stepper motor Resolution of burette: 1/150000 Minimum liquid volume for burette: 0.001mL Error range of burette: 1mL ± 0.01mL 5mL ±0.01mL 10mL ±0.02mL |
Electrode electrolysis currents of 10mA, 20mA, 50mA occur 100mA、200mA、400mA Maximum electrolysis rate: 37.35 μ g H2O/s (2241 μ g H2O/s) gH2O/min) Electrolytic accuracy: ≤ 0.2% Resolution: 0.1 μ g H2O |
|
| Number of methods | 150 pieces | |
| export format | Excel、PDF | |
| display mode | 10 inch TFT capacitive screen | |
| Graph display | E-T、V-T | E-T |
| Drift correction function | Manual, automatic, closed | |
| Compliant with FDA 21 CFR pat11 | yes | |
| audit trail | yes | |
| Permission Management | Four level permissions (super administrator, supervisor, operator, IT) | |
| number of users | 30 of them | |
| storage space | 8G | |
| sample pool | 120mL | 200mL |
| communication interface | WiFi、USB、 Ethernet RS232、BNC | |
| Mixing method | magnetic stirring | |
| Available printers | Wireless laser printer, wired micro printer | |
| power supply | Input voltage 100-240V ± 10% Input frequency 50-60Hz Output voltage 24VDC |
|