Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Schneider inverter ATV610 series, Shanghai first level agent $r $n Main information $r $n Product series $r $n Easy Altivar 610 $r $n Product type $r $n Inverter $r $n Application type $r $n Fan, pump, compressor, conveyor belt $r $n Product short name $r $nATV610 $r $n Variable $r $n Standard version $r $n Motor type $r $n Asynchronous motor $r $n Synchronous motor $r $n Installation type $r $n Cabinet mounted $r $n EMC filter $r $n Integrated with IEC 61800-3 safety level C3 and 50m longest motor cable

Product Details

Schneider inverter ATV610 series, Shanghai first level agent

Schneider inverter ATV610 series, Shanghai first level agent

Schneider inverter ATV610 series, Shanghai first level agent

Schneider inverter ATV610 series, Shanghai first level agent

Key information
Product Series Easy Altivar 610
Product Type frequency converter
Application Type Fan, pump, compressor, conveyor belt
Product Short Name ATV610
variable Standard version
Motor Type asynchronous motor
synchronous motor
Installation Type cabinet installation
EMC filter Integrated IEC 61800-3 safety level C3 and 50m longest motor cable
IP protection level IP20
cooling method forced ventilation
power supply frequency 50...60 Hz +/-5 %
Number of network phases 3 phases
power supply voltage 380...460 V - 15...10 %
Electric motor power (kW) 132 kW suitable for standard load
110 kW suitable for heavy loads
Motor power (hp) 200 hp suitable for standard load
150 hp suitable for heavy loads
Line current 237 A on... 380 V (standard load)
203.8 A on... 460 V (standard load)
201 A on... 380 V (heavy load)
174.2 A on... 460 V (heavy load)
Expected route Isc 50 kA
apparent power 162.4 kVA on... 460 V (standard load)
138.7 kVA on... 460 V (heavy load)
Continuous output current 250 A is suitable for standard load at 2.5 kHz on
211 A is suitable for heavy loads at 2.5 kHz on
Maximum transient current 275 A at 60 s (standard load)
317 A in 60 seconds (overloaded)
Asynchronous motor control configuration file Standard Variable Torque
Optimize torque mode
Standard constant torque
Output frequency 0.1…500 Hz
Rated switching frequency 2.5 kHz
switching frequency 1... 8 kHz adjustable
number of preset speeds 16 preset speeds
Communication Port Protocol Modbus Serial
tab Card slot A: Communication card, Profibus DP V1
Slot A: Logic or Analog I/O Expansion Card
Slot A: Relay output card

Supplementary information
output voltage <=Power supply voltage
Motor slip compensation Automatically regardless of load conditions
adjustable
Can suppress
Not applicable to the rules of permanent magnet synchronous motors
Acceleration and deceleration tilting S. U or custom
Independently linearly adjustable from 0.01 to 9000 seconds
Braking to stop Adopting DC injection
Protection type Thermal protection: motor
Motor phase failure: Motor
Thermal protection: Drive
Overheating: Drive
Overcurrent between output phase line and ground: driving
Output voltage overload: Drive
Short circuit protection: driver
Motor phase failure: Drive
DC bus overvoltage: driver
Line power overvoltage: Drive
Bus power supply undervoltage: drive
Bus power supply phase loss: drive
Overspeed: Drive
Braking on control circuit: Drive
frequency resolution Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5... 1.5 mm ²
Line side, screw terminal: 2 x 70... 3 x 120 mm ²
Motor, screw terminal: 3 x 70... 3 x 120 mm ²
port type 1 RJ45 (at remote graphics terminal) compatible with Modbus serial
physical interface 2-wire RS485 compatible with Modbus serial
Transmission frame RTU is compatible with Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s compatible with Modbus serial
polarization mode No impedance suitable for Modbus serial
Number of addresses 1... 247 is compatible with Modbus serial
Access method From (station)
power supply External power supply for logic input: 24 V DC (19... 30 V),<1.25 mA, protection type: overload and short circuit protection
Internal power supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC+/-5%,<10 mA, protection type: overload and short circuit protection
Local signal indication 2 LEDs for local diagnostics
1 LED (yellow) for integrated communication status
2 LEDs (dual color) for communication module status
1 LED (red) for voltage status
width 300 mm
height 850 mm
1161mm IP21 compliant installation kit
depth 375 mm
Net weight 85.5 kg
Number of analog inputs 3
Analog input type AI1, AI2, AI3 software - configurable voltage: 0... 10 V DC, impedance: 30 kOhm, resolution: 12 bits
AI1, AI2, AI3 software - configurable current: 0... 20 mA, impedance: 250 Ω, resolution 12 bits
AI2, AI3 software - configurable temperature detector or water level sensor
Discrete input quantity 6
Digital input type DI1... DI6 can be programmed as logic inputs, 24 V DC (<=30 V), impedance: 3.5 kOhm
DI5, DI6 can be programmed as pulse inputs: 0... 30 kHz, 24 V DC (<=30 V)
Input compatibility DI1... DI6: Logic input level 1 PLC complies with IEC 61131-2
DI5, DI6: Pulse Input Level 1 PLC Compliant with IEC 65A-68
Discrete input logic Positive logic (source): DI1... DI6 configurable logic inputs,<5V (state 0)11 V (State 1)
Negative logic (leakage): DI1... DI6 configurable logic inputs16 V (state 0)10 V (State 1)
Positive logic (source): DI5, DI6 configurable pulse input,<0.6 V (state 0),>2.5 V (state 1)
Quantity of analog output 2
Analog output model Software - Configurable current AQ1, AQ2: 0... 20 mA, resolution 10 bits
Software - Configurable voltage AQ1, AQ2: 0... 10 V DC impedance 470 Ω, resolution 10 bits
During the sampling period 5 ms+/-0.1 ms (AI1, AI2, AI3) - Analog input
2 ms+/-0.5 ms (DI1... DI6) configurable - discrete input
5 ms+/-1 ms (DI5, DI6) configurable - pulse input
10 ms+/-1 ms (AQ1, AQ2) - Analog output
precision +/-0.6% AI1, AI2, AI3 are used as analog inputs for temperature fluctuations at 60 ° C
+/-1% AQ1, AQ2 are used for analog output of temperature variation at 60 ° C
Linearity error AI1, AI2, AI3: Maximum value+/-0.15% applicable for analog input
AQ1, AQ2:+/-0.2% applicable for analog output
Number of relay outputs 3
Relay output type Configurable relay logic R1: Fault relay NO/NC electrical life 100000 times
Configurable relay logic R2: Sequence relay NO Electrical life 100000 times
Configurable Relay Logic R3: Sequence Relay NO Electrical Life 100000 Times
Update time Relay output (R1, R2, R3): 5 ms (+/-0.5 ms)
Minimum switch current [Imin] Relay outputs R1, R2, R3: 5 mA on... 24V DC
Maximum switch current Relay outputs R1, R2, R3 on... resistive (load) quantity, cos phi=1:3 A on... 250 V AC
Relay outputs R1, R2, R3 are resistive (load) quantities on..., cos phi=1:3 A is 30 V DC on
Relay outputs R1, R2, R3 on... inductive load, cos phi=0.4 L/R=7 ms: 2 A on... 250 V AC
Relay outputs R1, R2, R3 on... inductive load, cos phi=0.4 L/R=7 ms: 2 A on... 30 V DC
isolation Between the power supply and control terminals
insulation resistance >1 MOhm grounded for 1 minute at 500 V DC
environment
noise level 76 dB complies with 86/188/EEC
Power consumption W 2755 W (forced ventilation) on... 380 V, switching frequency 2.5 kHz
operating position Vertical direction+/-10 °
Electromagnetic Compatibility Static discharge reactance interference level 3 conforming to IEC 61000-4-2
Radio frequency electromagnetic field radiation immunity test level 3 conforming to IEC 61000-4-3
Anti fast transient level 4 conforming to IEC 61000-4-4
1.2/50 and 8/20 µ s composite wave (test) level 3 conforming to IEC 61000-4-5
Conforming to IEC 61000-4-6 for Conducted Fluctuations Caused by Radio Frequency Fields Level 3
pollution level 2. Complies with IEC 61800-5-1
Anti vibration Peak to peak 1.5 mm (f=2... 13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
impact-resistant 6 gn is suitable for 11 ms and complies with IEC 60068-2-27
relative humidity 5... 95% non condensing in accordance with IEC 60068-2-3
ambient temperature -15... 45 ° C (without capacity reduction)
45... 60 ° C (available)
working altitude =1000 meters without capacity reduction
1000... 4800 m current derating 1%/100m
environmental characteristics Chemical pollution resistance level 3C3 complies with IEC 60721-3-3
Dust pollution resistance level 3S3 complies with IEC 60721-3-3
standard IEC 61800-3
Environment 2 classification C3 IEC 61800-3
IEC 61800-5-1
IEC 60721-3
identification CE
packaging unit
Packaging 1: Type of packaging unit PCE
Per kilogram 1
Packaging 1: Height 45.500 cm
Packaging 1: Width 65.500 cm
Packaging 1: Length 103.000 cm
package weight 99.000 kg
Contract Warranty