Welcome Customer !

Membership

Help

Jiangsu Qixing Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Jiangsu Qixing Instrument Co., Ltd

  • E-mail

    m17351886899_1@163.com

  • Phone

    17351886899

  • Address

    No. 286 Tongtai Avenue, Jinhu County Economic Development Zone, Huai'an City, Jiangsu Province

Contact Now

Sanitary pulse output turbine flowmeter

NegotiableUpdate on 09/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product Description: QX-LWGY-K series sanitary pulse output liquid turbine flowmeter is a widely used flow measuring instrument in the pharmaceutical, food, beverage and other industries, as a measuring, ingredient, control, finished product filling and other purposes

Product Details

Product Description:

QX-LWGY-K seriesSanitary pulse output liquid turbine flowmeterIt is a widely used flow measuring instrument in industries such as pharmaceuticals, food, and beverages, used for metering, ingredient preparation, control, and finished product filling. The instrument housing is made of stainless steel (316L), and the movement part is made of special materials, which have good anti-corrosion and rust prevention capabilities. The entire structure breaks through traditional craftsmanship and adopts good anti-corrosion ability. Greatly improved the accuracy and repeatability of the instrument. Specially designed for the pharmaceutical and beverage industries, using a quick connect structure for easy cleaning. The YC-LWGY-K series sanitary turbine flowmeter has reached the international standard of similar products and is an ideal instrument for the sanitary industry.

Product Features:
The sensor is a hard alloy bearing thrust type, which not only ensures accuracy but also improves wear resistance.
International standards, can replace similar imported products.
Simple structure, sturdy and easy to disassemble.
Adopting a quick installation structure, it is easy to install and maintain
Wide measurement range, low lower limit flow rate.
Low pressure loss, good repeatability, and an accuracy of up to 0.5%.
Has good resistance to electromagnetic interference and vibration.

working principle:
When the fluid flows through the sensor housing of the turbine flowmeter, due to the angle between the blades of the impeller and the flow direction of the fluid, the impulse of the fluid causes the blades to have a rotational torque. After overcoming the friction torque and fluid resistance, the blades rotate. After the torque is balanced, the speed stabilizes. Under certain conditions, the speed is proportional to the flow velocity. Due to the magnetic conductivity of the blades, they are in the magnetic field of the signal detector (composed of permanent magnet and coil). The rotating blades cut the magnetic field lines and periodically change the magnetic flux of the coil, causing electrical pulse signals to be induced at both ends of the coil. This signal is amplified and shaped by an amplifier to form a continuous rectangular pulse wave with a certain amplitude, which can be transmitted far to the display instrument to display the instantaneous flow rate and cumulative flow rate of the fluid.

Flow Range Table:

Instrument diameter (mm)

Normal flow range (m?/h)

Expand flow range (m?/h)

Conventional withstand pressure (MPa)

DN4

0.04~0.25

0.04~0.4

1.6

DN6

0.1~0.6

0.06~0.6

1.6

DN10

0.2~1.2

0.15~1.5

1.6

DN15

0.6~6

0.4~8

1.6

DN20

0.8~8

0.45~9

1.6

DN25

1~10

0.5~10

1.6

DN32

1.5~15

0.8~15

1.6

DN40

2~20

1~20

1.6

DN50

4~40

2~40

1.6

DN65

7~70

5~70

1.6

DN80

10~100

5~100

1.6

DN100

20~200

10~200

1.6

Note: 1. DN15 and below are specially customized
2. The outer diameter of sanitary clamps with a diameter of DN25 or less is Ø 50.5mm, while the outer diameter of DN32 clamps with a diameter of Ø 50.5 is specially customized. Other clamp sizes are based on the matching pipe diameter.
3. Expanding traffic to non-standard traffic is not recommended.

Main technical parameters:

execution standard

Liquid turbine flow sensor (JB/T9246-1999)

Instrument diameter (mm)

DN4-80 can be connected with threads, DN4-DN80 can be connected with sanitary clamps, and DN4-DN200 can be connected with flanges,

accuracy class

±1%R、±0.5%R、

turndown ratio

1:10; 1:15; 1: 20 (requires customization)

Sensor material

316 (L) stainless steel

Terms of Use

Medium temperature: -20 ℃ to+80 ℃ (up to 150 ℃, customized); Environmental temperature: -20 ℃ to+60 ℃
Relative humidity: 5% to 90%; Atmospheric pressure: 86KPa~106KPa

Signal output function

Pulse signal, 4-20mA

Communication output function

RS485 communication, HART protocol, etc

Work energy

  • External power supply:+24VDC ± 15%, ripple ≤ ± 15%, suitable for 4-20mA output, pulse output, RS485, etc

  • Internal power supply: 1 set of 3.0V10AH lithium batteries, which can work normally when the battery voltage is between 2.0-3.0V.

Signal line interface

Explosion-proof rating

ExiaICIT4 or ExdIIBT6

Protection level

IP65 or higher (customizable)