Same day shipment of Sanfeng/Montetoyo surface roughness measuring instrument

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

On the same day, the Sanfeng/Montetoyo surface roughness measuring instrument $r $n was shipped. The compact integrated surface roughness measuring instrument $r $n is designed to meet customer needs. The color LCD display not only displays calculation results and measurement conditions, but also displays surface roughness waveforms. In addition, large-sized fonts make them more visible. $r $n ◆ Equipped with a rechargeable battery, it can also be measured in places without an external power source.

Product Details

Specification Overview
Same day shipment of Sanfeng/Montetoyo surface roughness measuring instrument
Same day shipment of Sanfeng/Montetoyo surface roughness measuring instrument

Specification Sheet
Item Number Standard driver type Backoff driver type Lateral drive type
SJ-210
(0.75mN type)
SJ-210
(4mN type)
SJ-210
(0.75mN type)
SJ-210
(4mN type)
SJ-210
(0.75mN type)
SJ-210
(4mN type)
model 178-560-11DC 178-560-12DC 178-562-11DC 178-562-12DC 178-564-11DC 178-564-12DC
measurement range X-axis 16.0 mm 5.6 mm
detector scope 360μm(-200μm~+160μm)
Range/Resolution 360μm / 0.02μm、100μm / 0.006μm、 25μm / 0.002μm
Force/Needle Measurement form Depending on item number: 0.75mN/2 μ mR 60 º (end of item number '-11') 4mN/5 μ mR 90 º (end of item number '-12')
Applicable standard JIS 1982/JIS 1994/JIS 2001/ISO 1997/ANSI/VDA
Evaluate the outline Original contour, roughness contour, DF contour, roughness motif contour
Usage
1. Remove the detector and install it into the roughness meter
2. Turn on the machine and check if the battery display is normal. Clean the surface of the workpiece being tested and place the instrument correctly and steadily on the surface of the workpiece being tested
3. Enter the main display interface for basic measurement status
4. Press the measurement button, the detector slides back and forth, and the instrument automatically measures
5. Measurement completed, display the surface roughness value of the measured object on the screen
Precautions
1. Strictly avoid collisions, severe vibrations, heavy dust, moisture, oil stains, strong magnetism, etc.
2. The selection of measurement conditions generally includes the selection of sampling length, evaluation length, and range for roughness meters, which depends on the size and surface finish of the workpiece.
3. When the battery voltage is insufficient, it should be charged in a timely manner to avoid affecting the testing accuracy.
4. Due to the fact that the detector is a highly precise component, careless disassembly and assembly may result in damage. Therefore, it is recommended to use it in a centralized manner during measurement to minimize the number of disassembly and assembly times.
5. Before measurement, the surface of the workpiece should be wiped clean to avoid oil, water, dust, etc., to prevent rusting of the sensor and extend its service life. At the same time, the measurement results are more accurate.
6. After use, please store the detector in the box in a timely manner. If it is not used for a long time, it must be charged in a timely manner to avoid the battery life being affected by the discharge of electricity.