Salt detection
If coating is applied to surfaces that have been contaminated but not pre treated, it can lead to premature coating damage and increase rework and maintenance costs.HONJAHAUS BresleSalt detection kitLightweight and portable, the instrument can detect the conductivity of a drop of sample and automatically convert it into salt content, allowing users to work according to 8502-6 or IS08502-9 without manual calculation.
The Bresle test is used to measure water-soluble salts and corrosion products on sandblasted steel. These compounds are almost colorless and located at the low point of the rust pit.
If it is not removed before painting, chemical reactions may cause blistering and rust accumulation, thereby damaging the adhesion between the substrate and the applied protective coating.
Technical Parameters
Conductivity meter accuracy:+2%
Conductivity meter measurement range: 0-1999uS/cm
Conductivity meter resolution: 1uS/cm Storage conditions: Do not expose to any extreme temperature or sunlight Shelf life: If exposed to extreme temperature,Salt detection kitThe stickiness on the salt patches may deteriorate, and we recommend using these patches within 12 months from the date of purchase. Compliancels08502-6andl508502-9.