Overview
The SZL coal-fired assembled boiler adopts a double drum longitudinal structure, which is divided into two series: SZL and QXL. The upper and lower parts are shipped from the factory, with a single-layer layout and patented water-cooled arch technology ..
Product Details

★ Boiler parameter range:
SZL4~30t/h(2.8~17.5MW)。

Technical Features:
SZL coal-fired assembled boilerAdopting a dual drum vertical structure, it is divided into two series: SZL and QXL. The upper and lower parts are shipped from the factory, with a single-layer layout and patented water-cooled arch technology. It has the characteristics of compact structure, easy operation, stable operation, fast temperature and pressure rise, sufficient output, adaptability to a wide range of coal types, and easy installation

★ Main characteristic parameters table of coal-fired steam boiler:
Technical specifications:

Parameters/Data model model model
SZL4-1.25-A II
SZL4-1.6-A II
SZL4-2.5-A II
SZL4-1.25/250-A II
SZL6-1.25-A II
SZL6-1.57A II
SZL6-2.5-A II
SZL6-2.5/350-A II
SZL8-1.25-A II
SZL8-1.57-A II
SZL8-2.5-A II
SZL8-1.25/280-AII
rated evaporation capacity t/h 4 6 8
Rated working pressure Mpa 1.25 1.25 1.25
Rated steam temperature °C 194 194 194
Water supply temperature °C 20 60 60
Heating surface area of boiler Radiation heating surface m2 16.4 22.4 25.2
Convective bundle m2 76.5 107.7 162.9
economizer m2 54.5 130.8 157
Effective area of grate m2 4.8 7.78 10.04
Applicable fuel
II. Class III bituminous coal II. Class III bituminous coal II. Class III bituminous coal
Boiler fuel consumption kg/h 505 775 1019
boiler thermal efficiency % 79.5 81.1 80.3
Maximum transport size (length x width x height) m 7x2.6x3.5 7x2.6x3.5 6.9x3.16x3.5
Maximum weight of transported items t 30 21 25

Supporting auxiliary equipment:
name Model and parameters Model and parameters Model and parameters
induced draft fan GY4-18 3 # Right 0 ° H=3960Pa GY6-18 # Right 0 ° H=4116Pa GY8-18 # Right 0 ° H=3910Pa
Motor Y180L-4B3 N=22kw Motor Y225S-4B3 N=37kw Motor Y225M-4 N=45kw
blower GG4-12 # Left 225 ° H=2740Pa GG6-1 Right 225 ° H=1960Pa GG8-1, right 225 ° H=2020Pa
Motor Y132S2-2 N=7.5kw Motor Y132M-4 N=7.5kw Motor Y132M-4 N=11kw
Electric feed pump DG6-25x7 H=175m DG12-25x6 H=150m DG12-25x7 H=175m
Motor Y132S2-2 N=7.5kw Motor Y160M1-2 N=11kw Motor Y160M2-2 N=15kw
Speed control box GL-5P/II stepless speed regulation GL-10P/II stepless speed regulation GL-16P/I stepless speed regulation
Motor YCT112-4A N=0.55kw Motor YCT112-4B N=0.75kw Motor YCT132-4A N=1.1kw
Slag extractor

spiral

——
spiral ——
spiral ——
Motor Y90L-6 N=1.1kw Motor Y90L-6 N=1.1kw Motor Y90L-6 N=1.1kw
dust collector Multi tube XTD-4 ——
Multi tube XTD-6 ——
Multi tube XTD-8 ——
Note: 1. The data in the table are allBoiler No
2. Fuel consumption is calculated based on the application base low calorific value of 5500kcal/kg coal type

★ Main characteristic parameters table of coal-fired hot water boiler:
Technical specifications:
Parameters/Data model model model
QXL2.8-0.7/95/70-A II
QXL2.8-1/115/70-A II
QXL4.2-1/115/70-A II
SZL4.2-1/95/70-A II
SZL4.2-1/115/70-A II
QXL5.6-1/95/70-A II
QZL5.6-1/115/70-A II
SZL5.6-1.25/130/70-A II
SZL5.6-1/115/70-A II
Rated thermal power MW 2.8 4.2 5.6
Rated working pressure Mpa 0.7 1 1
Rated outlet water temperature °C 95 115 115
Rated inlet water temperature °C 70 70 70
Heating surface area of boiler Radiation heating surface m2 14.66 20 25.2
Convective bundle m2 86.9 111.9 162.9
economizer m2 ——
130.8 130.8
Effective area of grate m2 4.8 7.68 10.04
Applicable fuel
II. Class III bituminous coal II. Class III bituminous coal II. Class III bituminous coal
Boiler fuel consumption kg/h 505 775 1020
boiler thermal efficiency % 79.6 81.1 80.3
Maximum transport size (length X width X height) m 7x2.6x3.5 7x2.6x3.5 6.9x3.16x3.5
Maximum weight of transported items t 30 21 25

Supporting auxiliary equipment:
name Model and parameters Model and parameters Model and parameters
induced draft fan GY4-18 3 # Right 0 ° H=3960Pa GY6-18 4 # Right 0 ° H=4116Pa GY8-18 right 0 ° H=3910Pa
Motor Y180L-4B3 N=22kw Motor Y225S4B3 N=37kw Motor Y225M-4 N=45kw
blower GG4-12 # Left 225 ° H=2740Pa GG6-1 Right 225 ° H=1960Pa GG8-1, right 225 ° H=2020Pa
Motor Y132S2-2B3 N=7.5kw Motor Y132M-4 N=7.5kw Motor 160M-4 N=11kw
Supply water pump JGGC4-8x11 H=88m JGGC8-8x14 H=112m JGGC8-112/14 H=112m
Motor Y90L-2 N=2.2kw Motor Y132S1-2B5 N=5.5kw Motor Y132S1-2B3 N=5.5kw
Speed control box GL-5P/II stepless speed regulation GL-10P/II stepless speed regulation GL-16P/I stepless speed regulation
Motor YCT112-4A N=0.55kw Motor YCT112-4B N=0.75kw Motor YCT132-4A N=1.1kw
Slag extractor spiral ——
spiral ——
spiral ——
Motor Y90L-6 N = 1.1kw Motor Y90L-6 N=1.1kw Motor Y90L-6 N=1.1kw
dust collector Multi tube XTD-4 ——
Multi tube XTD-6 ——
Multi tube XTD-8 ——
Note: 1. The data in the table are allBoiler No