Overview
The DZL coal-fired quick installation boiler adopts a horizontal quick installation external combustion three return water fire pipe mixed arrangement, which has a compact structure, fast start-up and ignition, sufficient output, high efficiency, and installation and maintenance ..
Product Details

★ Boiler parameter range:
DZL1~4t/h(0.7~2.8MW)。

Technical Features:

Adopting a horizontal quick installation external combustion three return water fire pipe hybrid layout, it has the characteristics of compact structure, fast starting and ignition, sufficient output, high efficiency, easy installation and maintenance, and low infrastructure investment.

Main characteristic parameters table of coal-fired steam boiler:

Technical specifications:

Parameters/Data model model model
DZL1-0.7-A II
DZL1-1-A II
DZL2-1-A II
DZL2-1.25-A II
DZL4-1.25-A II
DZL4-1.57-A II
rated evaporation capacity t/h 1 2 4
Rated working pressure Mpa 0.7 1 1.25
Rated steam temperature °C 170 183 194
Rated feedwater temperature °C 20 20 20
Heating surface area of boiler
ontology
m2 31.61 62.19 114.6
economizer
m2 21.12 121.12 38.5
Effective area of grate
m2 2.05 3.26 4.94
Applicable fuel

II. Class III bituminous coal II. Class III bituminous coal II. Class III bituminous coal
Boiler fuel consumption
kg/h 138 273 535
boiler thermal efficiency
% 80.1 79.5 79.5
Maximum transport size (length x width x height)
m 5.2x2x2.9 5.7x2.6x3.38 6.6x2.65x3.55
Maximum weight of transported items
tm 12.3 20 26.7

Supporting auxiliary equipment
name Model and parameters Model and parameters Model and parameters
induced draft fan GY1-18 4 # Right 0 ° H=2815Pa GY2-18 4 # Right 0 ° H=3340Pa GY4-18 3 # Right 0 ° H=3960Pa
Motor Y132S-4B N=5.5kw Motor Y160M-4B N=11kw Motor Y180L-4B3 N=22kw
blower 4-72-3.2A, right 315 ° H=792-1300Pa GG2-11 N0.6.3A H=1450Pa T4-72-4.5A, right 315 ° H=2539Pa
Motor Y90L-2 N=2.2kw Motor Y100L-2-4 N=3kw Motor Y132S2-2 N=7.5kw
Electric feed pump JGGC2-8X14 H=126m DG6-25X5 H=125m DG6-25X7 H=175m
Motor Y90L-2 N=2.2kw Motor Y132S1-2 N=5.5kw Motor Y132S2-2B3 N=7.5kw
Speed control box GL-5P/II stepless speed regulation GL-5P/II stepless speed regulation GL-5P/II stepless speed regulation
Motor YCT112-4A N=0.55kw Motor YCT112-4A N=0.55kw Motor YCT112-4A N=0.55kw
Slag extractor spiral ——
spiral ——
spiral ——
Motor Y90S-6 N=0.75kw Motor Y90S-6 N=1.1kw Motor Y90L-6 N=1.1kw
dust collector Multi tube XTD-1 ——
Multi tube XTD-2 ——
Multi tube XTD-4 ——
Note: 1. The data in the table are allBoiler No
2. Fuel consumption is calculated based on the application base low calorific value of 5500kcal/kg coal type

★ Main characteristic parameters table of coal-fired hot water boiler:
Technical specifications:
Data/Parameters model model model
DZL0.7-0.7/95/70-A II DZL1.4-0.7/95/70-A II DZL2.8-0.7/95/70-A II
Rated thermal power MW 0.7 1.4 2.8
Rated working pressure Mpa 0.7 0.7 0.7
Rated outlet water temperature °C 95 95 95
Rated inlet water temperature °C 70 70 70
Heating surface area of boiler ontology m2 28 48.6 86.53
Effective area of grate m2 2.23 3.26 4.94
Applicable fuel
II. Class III bituminous coal II. Class III bituminous coal II. Class III bituminous coal
Boiler fuel consumption kg/h 138 273 535
boiler thermal efficiency % 78.7 79 79.5
Maximum transport size (length X width X height) m 5.3x2.1x2.9 5.7x2.6x3.4 6.3x2.65x3.55
Maximum weight of transported items t 13 21 23

Supporting auxiliary equipment
name Model and parameters Model and parameters Model and parameters
induced draft fan GY1-18 4 # Right 0 ° H=2544Pa GY2-18 4 # Right 0 ° H=3340Pa GY4-18 4 # Right 0 ° H=3724Pa
Motor Y132S-4B3 N=5.5kw Motor Y160M-4B3 N=11kw Motor Y180L-4B3 N=22kw
blower 4-72N0.3.2A, right 315 ° H=637-1020Pa GG2-11 No.6.3A 右225° H=921Pa T4-72-4.5A, right 315 ° H=2539~1618Pa
Motor Y90L-2 N=2.2kw Motor Y100L-4 N=3kw Motor Y132S1-2 N=7.5kw
Supply water pump JGGC2-8X14 H=126m JGGC2-8X14 H=126m JGGC4-88/11 H=88m
Motor Y900L-2B5 N=2.2kw Motor Y90L-2 N=2.2kw Motor Y90L-2 N=2.2kw
Speed control box GL-5P/II stepless speed regulation GL-5P/II stepless speed regulation GL-5P/II stepless speed regulation
Motor YCT112-4A N=0.55kw Motor YCT112-4A N=0.55kw Motor YCT112-4A N=0.55kw
Slag extractor spiral ——
spiral ——
spiral ——
Motor Y90S-6 N=0.75kw Motor Y90L-6 N = 1.1kw Motor Y90L-6 N=1.1kw
dust collector Multi tube XTD-1 ——
Multi tube XTD-2 ——
Multi tube XTD-4 ——
Note: 1. The data in the table are allBoiler No
2. Fuel consumption is calculated based on the application base low calorific value of 5500kcal/kg coal type