SWP7081 thermal resistance isolated safety barrier paperless recorder/flash alarm/pressure transmitter/temperature inspection instrument/group/instrument agent/technology group/instrument SWP manual/manual SWP manual/intelligent flow integrator/instrument selection/Changhui temperature transmitter/digital display instrument manual/instrument/SWP instrument/automation instrument/instrument will come from hazardous areas
SWP7081 Thermal Resistance Isolation Safety BarrierPaperless recorder/flash alarm/pressure transmitter/temperature inspection instrument/group/instrument agent/technology group/instrument SWP manual/manual SWP manual/intelligent flow accumulator/instrument selection/Changhui temperature transmitter/digital display instrument manual/instrument/SWP instrument/automation instrument/instrument will come from hazardous areas
This product requires independent power supply, with power, input, and output isolated. The insulation strength of the local and non local ends is as high as2500V,a.c.Thermal resistance isolated safety barrier
Model |
additional code |
Explanation |
SWP7083-Ex |
/□ |
/□ |
/□ |
Thermal resistance isolation safety barrier |
input type |
/CU50 |
|
|
Cu50 (range: -50~150 ℃) |
/Pt100 |
|
|
Pt100 (range: -199~850 ℃) |
/Pt100.1 |
|
|
Pt100.1 (Range: -19.9~320.0 ℃) |
Channel 1 output type |
/I |
|
Channel 1: 4-20mA output (safe zone) |
/V |
|
Channel 1:1~5V output (safe zone) |
Channel 2 output type |
/I |
Channel 2: 4-20mA output (safe zone) |
/V |
Channel 2:1 to 5V output (safe zone) |
Note: If the user orders a channel output type, it will be produced and shipped according to the output type of 4-20mA.
Specifications |
Explanation |
number of channels |
one in, two out |
Explosion proof mark |
[Exia]ⅡC |
Adapt to the Place |
Installed in a safe place, it can be connected to intrinsically safe instruments in Zone 0 hazardous areas with IIA, IIB, and IIC hazardous gases. |
power supply voltage |
20~35VDC |
power consumption |
≤ 2.3W (24V power supply, 20mA output) |
Dangerous zone signal |
thermocouple
signal type |
measurement range |
B |
500~1820℃ |
S |
-50~1769℃ |
K |
-50~1372℃ |
E |
-50~1000℃ |
T |
-200~320℃ |
J |
-50~1200℃ |
WRe(3-25) |
0~2300℃ |
thermal resistor
signal type |
measurement range |
CU50 |
-50.0~150.0℃ |
PT100 |
-199~850℃ |
PT100.1 |
-199.9~320.0℃ |
(The user needs the signal type and range when placing an order)
|
Safety zone signal |
Current output: 4-20mADC
Load resistance: ≤ 800 Ω
Voltage output: 1-5VDC
Load resistance: ≥ 10K Ω
(Users need to select current or voltage output when placing orders)
|
power protection |
Reverse power protection |
output accuracy |
0.3%F.S |
temperature drift |
0.01%F.S/℃ |
Instrument structure |
Nylon plastic shell structure |
weight |
About 150g |
Applicable on-site equipment |
Two wire and three wire transmitters |
SWP7081 Thermal Resistance Isolation Safety Barrier
|
Model |
additional code |
Explanation |
SWP7081-Ex |
/□ |
/□ |
/□ |
Thermocouple isolation safety barrier |
input type |
/B |
|
|
B (Range: 500-1820 ℃) |
/S |
|
|
S (Range: -50~1769 ℃) |
/K |
|
|
K (range: -50~1372 ℃) |
/E |
|
|
E (Range: -50~1000 ℃) |
/T |
|
|
T (Range: -200~320 ℃) |
/J |
|
|
J (Range: -50~1200 ℃) |
/W |
|
|
WRe (3-25) (Range: 0-2300 ℃) |
Channel 1 output type |
/I |
|
Channel 1: 4-20mA output (safe zone) |
/V |
|
Channel 1:1~5V output (safe zone) |
Channel 2 output type |
/I |
Channel 2: 4-20mA output (safe zone) |
/V |
Channel 2:1 to 5V output (safe zone) |
★ Thermal resistance isolated safety barrier
Model |
additional code |
Explanation |
SWP7083-Ex |
/□ |
/□ |
/□ |
Thermal resistance isolation safety barrier |
input type |
/CU50 |
|
|
Cu50 (range: -50~150 ℃) |
/Pt100 |
|
|
Pt100 (range: -199~850 ℃) |
/Pt100.1 |
|
|
Pt100.1 (Range: -19.9~320.0 ℃) |
Channel 1 output type |
/I |
|
Channel 1: 4-20mA output (safe zone) |
/V |
|
Channel 1:1~5V output (safe zone) |
Channel 2 output type |
/I |
Channel 2: 4-20mA output (safe zone) |
/V |
Channel 2:1 to 5V output (safe zone) |