The SWP-LED series multi-channel inspection controller is used for the patrol inspection, display, and alarm of multiple measurement points in industrial control systems.
1、 Main features
It is possible to choose between unified alarm control output (or unified transmission output) for each input channel or separate alarm control output (or separate transmission output) for each input channel. Each channel has a unified alarm control output and can choose to alarm with memory (if any channel alarm is not cleared, it will continue to alarm until all channels have no alarms) or alarm without memory (output an alarm when cycling to a channel with an alarm, and no alarm when cycling to a channel without an alarm).
2、 Instrument appearance and wiring diagram(The following is the basic wiring method, please refer to the random wiring diagram for special orders)


3、 SWP-LED series multi-channel inspection, measurement and control instrument type chart

For special models or requirements, please provide the index number or reference standard, and specify it when placing an order.
★ Input type

★ Alarm mode

★ Communication method

★ Control output mode

★ Control function

★ Note 1: Instruments generally input the same type of signal. If different signals need to be input for each channel, please specify the input signal type for each channel in detail when ordering.
★ Note 2: Unified control/alarm output: that is, all channels of the instrument share one (or two) alarm output relay, or all channels share one set of transmission control outputs. The unified control/alarm output instrument is divided into the following two alarm modes (instruments without alarm memory are provided unless otherwise specified).
A. Without alarm memory function: If there is an alarm in the current channel during patrol, an alarm will be output. If there is no alarm in the lower channel during patrol, the alarm output will be turned off.
B. Equipped with alarm memory function: When there is an alarm in the current channel during patrol, an alarm will be output. If there is no alarm in the lower channel during patrol, the alarm output will continue until all channels have no alarm, and the police will stop outputting.
C. Separate control/alarm output: That is, each measurement channel of the instrument has one (or two) alarm relay output alarm, and the alarm outputs are independent of each other. Or each measurement channel has a set of independent transmission control outputs. When the input channel is ≤ 8, the upper and lower limit/channel alarm outputs can be selected separately. When the input channel is>8 or ≤ 16, the upper or lower limit/channel alarm outputs can be selected.
★ Model example:
① SWP-MD807-21-08-HL-K-W
Unified control/alarm output for eight channel inspection, communication method is RS232, output method is relay output, input type is Pt100, one channel alarm is upper limit alarm, second channel alarm is lower limit alarm, with alarm memory function, DC24V power supply, horizontal meter.