| Selection Table for SWP-C80/SWP-C90/SWP-0/SWP-C70/SWP-C10 Series Intelligent Digital Display Instruments |
| Model number |
Code |
Explanation |
| SWP- |
Intelligent Instrument SWP-C803-01 |
|
| Appearance characteristics |
|
|
|
|
|
|
|
|
|
|
| Horizontal digital display instrument |
| Vertical digital display instrument |
|
| External dimensions |
|
|
|
|
|
|
|
|
|
| 48×48mm |
| 96 × 48mm (horizontal), 48 × 96mm (vertical) |
| 72×72mm |
| 160 × 80mm (horizontal), 80 × 160mm (vertical) |
| 96×96mm |
|
| Control function |
|
|
|
|
|
|
|
|
| Measurement display table |
| Three position control table (display)+Upper and lower limit alarms |
| Four limit control or four limit alarm meter (display)+Four alarm outputs) |
|
| Communication method |
□ |
|
|
|
|
|
|
Refer to "Communication Methods" |
| Output method |
□ |
|
|
|
|
|
Refer to 'Output Method' |
| Input Type |
□ |
|
|
|
|
Refer to 'Input Types' |
| *Alarm method |
|
|
|
|
| No alarm (can be omitted) |
| Upper limit control/alarm (four limit control/alarm 2H) |
| Lower limit control/alarm (2L for four limit control/alarm) |
|
| Second alarm method |
|
|
|
| No alarm (can be omitted) |
| Upper limit control/alarm (four limit control/alarm 2H) |
| Lower limit control/alarm (2L for four limit control/alarm) |
|
| Feed output |
P |
|
DC24V power supply output |
| Power supply mode |
|
| DC24V power supply |
| AC90-265V power supply (switch mode power supply) |
| AC220V power supply (linear power supply, can be omitted) |
|
|
| Instrument input type |
| code |
Input Type |
measuring range |
code |
Input type |
measuring range |
code |
Input Type |
measuring range |
| 01 |
B |
400~1800 ℃ |
09 |
Pt100.1 |
-99.9~199.9℃ |
17 |
30-350Ω |
-1999~99999d |
| 02 |
S |
0 ~1600 ℃ |
10 |
Cu50 |
-50.0~150.0 ℃ |
18 |
Special specifications |
User specific |
| 03 |
K |
0 ~1300 ℃ |
11 |
Cu100 |
-50.0~150.0 ℃ |
19 |
4-20mA square meter |
-1999~99999d |
| 04 |
E |
0 ~1000 ℃ |
12 |
4~20mA |
-1999~99999 d |
20 |
0-10m square meter |
-1999~99999d |
| 05 |
T |
-200~400 ℃ |
13 |
0~10mA |
-1999~99999 d |
21 |
1-5V square root |
-1999~99999d |
| 06 |
J |
0 ~1200 ℃ |
14 |
1~5V |
-1999~99999 d |
22 |
0-5V square root |
-1999~99999d |
| 07 |
Wre |
0 ~2300 ℃ |
15 |
0~5V |
-1999~99999 d |
23 |
Switchable input |
Please refer to the table below for details |
| 08 |
Pt100 |
-200~650 ℃ |
16 |
0~20mA |
-1999~99999 d |
24 |
Frequency input |
0-5kHz |
|
| To fully switch inputs, simply set the secondary parameters of the instrument to switch between multiple division marks. The division marks that can be input are as follows: |
| code |
Input type |
code |
Input type |
code |
Input Type |
code |
Input type |
code |
Input Type |
| 01 |
B |
05 |
T |
09 |
Pt100.1 |
14 |
1~5 V |
18 |
1-5V square root |
| 02 |
S |
06 |
J |
10 |
Cu50 |
15 |
0~5 V |
19 |
0-5V square root |
| 03 |
K |
07 |
WRe |
12 |
4~20 mA |
16 |
4-20 mA square root |
|
|
| 04 |
E |
08 |
Pt100 |
13 |
0~10 mA |
17 |
0-10mA square root |
|
|
|
| Transmission output mode |
| Selection code |
0 |
1 |
2 |
3 |
4 |
5 |
8 |
| Output method |
no-output |
Alarm output |
| Transmission output 4-20mA |
| Alarm with relay |
|
| Transmission output 0-10mA |
| Alarm with relay |
|
| Transmission output 1-5V |
| Alarm with relay |
|
| Transmission output 0-5V |
| Alarm with relay |
|
Special specifications |
|
| Communication method |
| Selection code |
0 |
2 |
4 |
8 |
9 |
| Communication method |
No communication |
RS-232 |
RS-422 |
RS-485 |
Special specifications |
|
| Note 1: The SWP-C801 and SWP-C803 series are 0.8-inch LED displays, SWP-C901、SWP-C903、SWP-S801、SWP-S803、SWP-C701、 |
| The SWP-C703, SWP-01, and SWP-03 series have 0.56-inch LED displays, while the SWP-C101/C101 series have 0.32-inch LED displays. |
| Note 2: The four limit control or four limit alarm output is controlled by four relays, and users can modify internal parameters to set the desired control or alarm mode. |
| (Four limit control/alarm is only available for SWP-C804/S804 and C904 series, 2H represents two upper limit control/alarm, 2L represents two lower limit control/alarm). |
| Note 3: For the same division number, the selection code and instrument programming code are different. Please pay attention when setting the instrument. |
| Note 4: SWP-C701/SWP-C703 and SWP-C101/SWP-C103 have no frequency signal input. |
| |
| Model example: Intelligent instrument SWP-C803-01 |
| Example 1: SWP-C801-00-23-N-P |
| Display instrument, without communication and transmission output, 4-20mA (universal) input, with DC24V output fed, the instrument has an appearance of 160 × 80mm |
| Example 2: SWP-C801-02-03-N |
| Measurement shows that the instrument has no communication, the transmission output is 4-20mA, the K division mark (universal) input, the instrument is powered by AC220V, and the instrument has a vertical shape of 160 × 80mm |
| Example 3: SWP-C803-01-23-HL |
| Measurement display+alarm, instrument without communication and transmission output, Pt100 (universal) input, with upper and lower limit alarm/control output, powered by AC220V outside the instrument, |
| The instrument has a horizontal shape of 160 × 80mm. |
| Example 4: SWP-C803-02-12-HL-P |
| Measurement display+alarm, instrument no communication, transmission output 4-20mA, Pt100 (universal) input, with upper and lower limit alarm/control output, with feeding DC24V output, |
| The instrument is powered by AC220V and has a horizontal shape of 160 × 80mm. |
| Example of incorrect model: SWP-C801-02-12-HL-P |
| Reason for selection error: The SWP-C801 display instrument does not have an alarm function (code in the model: HL) |
| Example of correct model: SWP-C803-02-12-HL-P |