Anhui Donglin Automation Instrument Complete Set Co., Ltd. is a modern economic entity that integrates development, design, manufacturing, sales, and service. The company mainly produces thermocouples, thermistors, bimetallic thermometers, pressure gauges, transmitters, LDE electromagnetic flow meters, LUGB vortex flow meters, turbine flow meters, metal tube flow meters, glass tube flow meters, mass flow meters, spiral vortex flow meters, orifice flow meters, V-cone flow meters, Annubar flow meters, guided wave radar level meters, pulse radar level meters, high-frequency radar level meters, ultrasonic level meters, SWP-C803-01-23-HL temperature controller
SWP-C803-01-23-HL Temperature Controller
Digital display deviceSWP-C101-00-23-N
Digital display controllerSWP-C103-01-23-HL
Digital display deviceSWP-C401-00-23-N
Digital display deviceSWP-C401-02-23-N
Digital display controllerSWP-C403-01-23-HL
Digital display controllerSWP-C403-02-23-HL
Digital display deviceSWP-C701-00-23-N
Digital display deviceSWP-C701-02-23-N
Digital display controllerSWP-C703-01-23-HL
Digital display controllerSWP-C703-02-23-HL
Digital display deviceSWP-C801-00-23-N
Digital display deviceSWP-C801-02-23-N
Digital display controllerSWP-C803-01-23-HL
Digital display controllerSWP-C803-02-23-HL
Digital display controllerSWP-C804-01-23-HHLL
Digital display controllerSWP-C804-02-23-HHLL
Digital display deviceSWP-C901-00-23-N
Digital display deviceSWP-C901-02-23-N
Digital display controllerSWP-C903-01-23-HL
Digital display controllerSWP-C903-02-23-HL
Digital display controllerSWP-C904-01-23-HHLL
Digital display controllerSWP-C904-02-23-HHLL
Light column display instrumentSWP-T801-00-23-N
Light column display instrumentSWP-T801-02-23-N
Light column display controllerSWP-T803-01-23-HL
Light column display controllerSWP-T803-02-23-HL
Light column display controllerSWP-T804-01-23-HHLL
Light column display controllerSWP-T804-02-23-HHLL
Dual circuit digital display instrumentSWP-D421-00-23/23-N
Dual circuit digital display instrumentSWP-D821-00-23/23-N
Dual circuit digital display instrumentSWP-D821-022-23/23-N
Dual circuit digital display controllerSWP-D823-011-23/23-HL/HL
Dual circuit digital display controllerSWP-D823-022-23/23-HL/HL
Dual circuit digital display instrumentSWP-D721-00-23/23/-N
Dual circuit digital display controllerSWP-D723-011-23/23-HL/HL
Dual circuit digital display instrumentSWP-D921-00-23/23/-N
Dual circuit digital display controllerSWP-D923-011-23/23-HL/HL
Dual circuit light column display instrumentSWP-T821-00-23/23-N
Dual circuit light column display instrumentSWP-T821-022-23/23-N
Dual circuit light column display controllerSWP-T823-011-23/23-HL/HL
Dual circuit light column display controllerSWP-T823-022-23/23-HL/HL
| |
|
Product Introduction
SWP-LED digital display controller/light column display controller
|
|
Product application scope: SWP-C803-01-23-HL-P is widely used in industries such as aviation, petroleum, chemical, cement plants, pharmaceutical plants, sugar mills, paper mills, automation installation engineering, dyeing production equipment, etc.
|
The SWP-LED series digital display controller/light column display controller adopts a microprocessor for control operation, which can perform high-precision linear correction measurement on various nonlinear input signals. |
The SWP-LED series light column display controller integrates digital and analog instruments, and can perform digital display control (high brightness LED digital display) and relative analog display (light column display) on measurement signals such as temperature, pressure, liquid level, and speed, making the display of measurement values clearer and more intuitive, and can choose dual light column display mode. |
1、 Main features |
Adopting a universal input without jumper settings, each instrument can adapt to various indexing numbers through simple and quick parameter settings. |
| |
2、 Instrument appearance and wiring diagram (the following is the basic wiring, please refer to the random wiring diagram for special orders) |
model |
SWP-C803 series |
Wiring diagram |
Instrument appearance |
Instrument size: 160 × 80 × 140mm Hole size: 152 × 76mm Weight: 400g
|
|
model |
SWP-T803 series (horizontal) |
Instrument appearance |
Instrument size: 160 × 80 × 140mm Hole size: 152 × 76mm Weight: 400g
|
model |
SWP-S803 series |
Instrument appearance |
Instrument size: 80 × 160 × 140mm Hole size: 76 × 152mm Weight: 400g
|
model |
SWP-T801 series (vertical) |
Instrument appearance |
Instrument size: 80 × 160 × 140mm Hole size: 76 × 152mm Weight: 400g
|
model |
SWP-C401, C403 series (horizontal) |
Wiring diagram |
Instrument appearance |
Instrument size: 96 × 48 × 140mm Hole size: 92 × 44mm Weight: 240g
|
|
model |
SWP-S401, S403 series (vertical) |
Instrument appearance |
Instrument size: 48 × 96 × 140mm Hole size: 44 × 92mm Weight: 240g
|
model |
SWP-C901, C903 series |
Wiring diagram |
Instrument appearance |
Instrument size: 96 × 96 × 140mm Hole size: 92 × 92mm Weight: 400g
|
|
model |
SWP-C701, C703 series |
Wiring diagram |
Instrument appearance |
Instrument size: 72 × 72 × 110mm Hole size: 68 × 68mm Weight: 240g
|
|
model |
SWP-C101, C103 series |
Wiring diagram |
Instrument appearance |
Instrument size: 48 × 48 × 110mm Hole size: 44 × 44mm Weight: 180g
|
|
|
|
3、 SWP-LED series digital display control instrument type chart |
Model |
code |
Remarks |
SWP - |
□ □ □ □ - □ □-□□-□ □ -□ □ |
New Series |
Appearance characteristics |
|
|
|
|
|
|
|
|
|
|
Horizontal display instrument |
Vertical display instrument |
|
External dimensions |
|
|
|
|
|
|
|
|
|
48×48mm |
96 × 48mm (horizontal), 48 × 96mm (vertical) |
72×72mm |
160 × 80mm (horizontal), 80 × 160mm (formula) |
96×96mm |
|
Control function |
|
|
|
|
|
|
|
|
Measurement display |
| Three position control |
Four limit control or four limit alarm output |
|
Communication method |
□ |
|
|
|
|
|
|
Refer to 'Communication Methods' |
Output |
□ |
|
|
|
|
|
Refer to 'Transmission Output Method' |
Input Type |
□□ |
|
|
|
|
Refer to 'Input Types' |
*Alarm method |
|
|
|
|
No alarm (can be omitted) |
Upper limit control/alarm (four limit control/alarm 2H) |
Lower limit control/alarm (2L for four limit control/alarm) |
|
Second alarm method |
|
|
|
No alarm (can be omitted) |
Upper limit control/alarm (four limit control/alarm 2H) |
Lower limit control/alarm (2L for four limit control/alarm) |
|
Feed output |
P |
|
DC24V power supply output |
Power supply mode |
|
DC24V power supply |
AC90-265V power supply (switch mode power supply) |
AC220V power supply (linear power supply, can be omitted) |
|
|
4、 SWP-LED series light column measurement display control instrument type chart |
Model |
code |
explain |
SWP - |
T □ □ □-□ □-□□- □ □ - □ □- □ |
|
External dimensions |
8 |
|
|
|
|
|
|
|
|
|
160 × 80mm (horizontal), 80 × 160mm (vertical) |
Control function |
|
|
|
|
|
|
|
|
|
Measurement display |
Three position control |
Four limit control or four limit alarm output |
|
Communication method |
□ |
|
|
|
|
|
|
|
Refer to 'Communication Methods' |
Output |
□ |
|
|
|
|
|
|
Refer to 'Transmission Output Method' |
Input Type |
□□ |
|
|
|
|
|
Refer to 'Input Types' |
*Alarm method |
|
|
|
|
|
No alarm (can be omitted) |
Upper limit control/alarm (four limit control/alarm 2H) |
Lower limit control/alarm (2L for four limit control/alarm) |
|
Second alarm method |
|
|
|
|
No alarm (can be omitted) |
Upper limit control/alarm (four limit control/alarm 2H) |
Lower limit control/alarm (2L for four limit control/alarm) |
|
Feed output |
P |
|
|
DC24V power supply output |
Power supply mode |
|
|
DC24V power supply |
AC90-265V power supply (switch mode power supply) |
AC220V power supply (linear power supply, can be omitted) |
|
Display mode |
|
Horizontal display instrument |
Vertical display instrument |
|
|
★ Input type |
code |
Input type |
Measurement range |
code |
Input Type |
Measurement range |
code |
Input Type |
Measurement range |
01 |
B |
400~1800 ℃ |
09 |
Pt100.1 |
-99.9~199.9℃ |
17 |
30~350Ω |
-1999~99999 d |
02 |
S |
0 ~1600 ℃ |
10 |
Cu50 |
-50.0~150.0 ℃ |
18 |
Special specifications |
User specific |
03 |
K |
0 ~1300 ℃ |
11 |
Cu100 |
-50.0~150.0 ℃ |
19 |
4-20 mA square root |
-1999~99999 d |
04 |
E |
0 ~1000 ℃ |
12 |
4~20 mA |
-1999~99999 d |
20 |
0-10mA square root |
-1999~99999 d |
05 |
T |
-200~400 ℃ |
13 |
0~10 mA |
-1999~99999 d |
21 |
1-5 V square root |
-1999~99999 d |
06 |
J |
0 ~1200 ℃ |
14 |
1~5 V |
-1999~99999 d |
22 |
0-5V square root |
-1999~99999 d |
07 |
Wre |
0 ~2300 ℃ |
15 |
0~5 V |
-1999~99999 d |
23 |
Switchable input |
Please refer to the table below for details |
08 |
Pt100 |
-200~650 ℃ |
16 |
0~20 mA |
-1999~99999 d |
24 |
Frequency input |
0~5kHz |
|
★ Full switching input only requires setting the secondary parameters of the instrument to switch input multiple division marks. The division marks that can be input are as follows: |
code |
Input Type |
code |
Input type |
code |
Input Type |
code |
Input Type |
code |
Input type |
01 |
B |
05 |
T |
09 |
Pt100.1 |
14 |
1~5 V |
18 |
1-5V square root |
02 |
S |
06 |
J |
10 |
Cu50 |
15 |
0~5 V |
19 |
0-5V square root |
03 |
K |
07 |
WRe |
12 |
4~20 mA |
16 |
4-20 mA square root |
|
|
04 |
E |
08 |
Pt100 |
13 |
0~10 mA |
17 |
0-10mA square root |
|
|
|
★ Transmission output mode |
Selection code |
0 |
2 |
3 |
4 |
5 |
8 |
Output |
no-output |
4~20mA |
0~10mA |
1~5V |
0~5V |
Special specifications |
|
★ Communication method |
Selection code |
0 |
2 |
4 |
8 |
9 |
Communication method |
No communication |
RS-232 |
RS-422 |
RS-485 |
Special specifications |
|
Note 1: The C80 series has a 0.8-inch LED display, the C90, S80, C70, and C40 series have a 0.56-inch LED display, and the C10 series has a 0.32-inch LED display. |
★ Note 2: The four limit control or four limit alarm output is controlled by four relays, and users can modify internal parameters to set the desired control or alarm mode. (Four limit control/alarm is only available for T.C80, S80, and C90 series, 2H represents two upper limit control/alarm, 2L represents two lower limit control/alarm). |
★ For the same division number, the selection code and instrument programming code are different. Please pay attention when setting the instrument. |
Note 3: C70 and C10 have no frequency signal input. |
★ Model example:SWP-C803-01-23-HL Temperature Controller |
SWP-C803-21-08-HL-T |
Measurement display, communication method is RS232, output method is relay output, input type is PT100, * alarm is upper limit alarm, second alarm is lower limit alarm, AC90-260V power supply. |
|
|