- Phone
-
Address
508, Building 4, Lane 680, Shuishe West Road, Baoshan District, Shanghai
Shanghai Xuji Electric Co., Ltd
508, Building 4, Lane 680, Shuishe West Road, Baoshan District, Shanghai
STHD-5A Grounding Resistance Tester for Earth Network

The maximum open circuit voltage output of the digital large-scale grounding resistance tester can reach400V, The maximum short-circuit current can reach 5A. The microprocessor control and automatic dual frequency technology can accurately measure and calculate the grounding impedance value at 50Hz power frequency under strong interference conditions, and the large screen display is clear at a glance. Simultaneously store 100 sets of data, with a resistance measurement range of 0.000 Ω to 2000 Ω. Measurement data can be printed out through a thermal printer.
The digital large-scale grounding resistance tester for ground grids consists of a host, test lines, grounding rods, etc., and has a history ofFunctions such as reading, querying, saving, and printing historical data.
merit can |
Ground resistance measurement, soil resistivity measurement, step voltage measurement, distributed potential measurement, contact voltage measurement |
Grounding impedance |
0.000-2000 Ω Accuracy: ± 0.5% FS ± 5dgt Minimum Resolution: 0.001 Ω |
Soil resistivity measurement |
0.000~999K Ω m Minimum resolution: 0.001 Ω m |
Step voltage measurement, distributed potential measurement, contact voltage measurement |
0~400V minimum resolution: 0.001V |
Impedance angle measurement (radians) |
0~360.0 ° resolution: 0.1 ° |
Rated measurement power |
2000W |
anti-interference capability |
Anti power frequency50Hz voltage 50V |
Benchmark conditions |
23 ℃± 5 ℃, below 70% RH (auxiliary grounding resistance 20 Ω± 10%, ground voltage<10V) |
electricity source |
AC 220V 10A (50Hz) |
back light |
Adjustable backlight brightness |
measurement method |
Four wire test, three wire test, two wire test |
measurement method |
Grounding impedance: rated current method, |
Short circuit test current |
1A, 2A, 3A, 4A, 5A (5-speed setting) |
Soil resistivity electrode spacing Fan enclose |
Configurable1m~100m |
test frequency |
45Hz、55Hz、 Automatic dual band option |
Maximum short-circuit current |
AC 5A ± 10% sine wave |
Maximum no-load voltage |
AC 400V ± 10% sine wave |
display mode |
7-inch touch color screen |
touch screen |
is |
Measurement indication |
Measurement progress display, measurement prompt animation display |
Instrument size |
Length, width, height:540mm×440mm×210mm |
Standard test line length |
red15m, Black 15m, yellow 10m, green 10m, yellow 1.5m, green 1.5m each |
Auxiliary grounding rod |
800mm 2 pieces, 200mm 2 pieces |
measure time |
Grounding impedance: approximately1 minute/time |
hit India |
Built in thermal printer |
Printing paper specifications |
57*40mm |
data storage |
100 sets, "Save successfully!" storage indication, displaying "Save failed, space is full!" character indicating storage is full |
data lookup |
have |
Overflow display |
Over range overflow function:The symbol 'OL' is displayed |
Auto Shutdown |
Nothing |
merit consume |
standby: <110W |
Measurement:2000W | |
quality quantity |
meter:27 kg |
Test line, auxiliary grounding rod, instrument bag:5.5kg | |
Working temperature and humidity |
-10℃~40℃; Below 80% RH |
Storage temperature and humidity |
-20℃~60℃; Below 70% RH |
insulation resistance |
Above 10M Ω (500V between circuit and casing) |
endure press |
AC 3700V/rms (between circuit and casing) |
electromagnetic properties |
IEC61010-4-3, Wireless frequency electromagnetic field ≤ 1V/m |
Suitable for safety regulations |
IEC61010-1、IEC1010-2-31、IEC61557-1,5、IEC60529(IP54)、 污染等2、 CAT Ⅲ 300V |
STHD-5A Grounding Resistance Tester for Earth Network

ceremony table |
1 unit |
ceremony table bag |
1 piece |
Auxiliary grounding rod |
4 pieces |
measure try line |
4 pieces (red 15m, black 15m, yellow 10m, green 10m each) |
Simple testing line |
2 pieces (1 yellow 1.5m, 1 green 1.5m each) |
220V power cord |
1 item |
Instruction manual, warranty certificate |
1 set |