Welcome Customer !

Membership

Help

Shanghai Xinrui Filter Materials Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Xinrui Filter Materials Co., Ltd

  • E-mail

    82104428@qq.com

  • Phone

    18918959380

  • Address

    Building 3, No. 725 Dongshe Road, Dongjing District, Songjiang Industrial Park, Shanghai

Contact Now

SRA Roll up Filter

NegotiableUpdate on 11/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Automatic replacement of filter media pressure difference control structure with simple outer frame: The entire Autoroll adopts a metal structure, which is sturdy and reliable, and can meet harsh working environments

Product Details


Automatic replacement of filter material
Differential pressure control
simple structure
Frame: The Autoroll adopts a metal structure as a whole, which is sturdy and reliable, and can meet harsh working environments. The intelligent filter material replacement system can meet the requirements of complex airflow systems, save limited energy, reduce manpower, and make operation more economical and stable.
Efficiency: (EN779:2002) G4, F5;
(ASHRAE 52.2:2007)MERV7,MERV8。
Filter material: composed of high-performance and fracture resistant synthetic fiber filter materials, with an increasing structure, large dust holding capacity, high efficiency, and no silicon content


Automatic Renewable media Air Filter
Pressure Differential Detector System
Easy Installation,Simply Design

Autoroll-Filter constructed by cold roll steel with powder coated surface to provide a rigidly and reliable structure,which can withst and severe operating condition. This system is installed at environment require air filtration system ,frequent change of filter and accessibility is critical . Low power consumption,reduce manpower and reliable operation .
Efficiency:(EN779:2002 filter class)G4,F5
(ASHRAE 52.2:2007 filter class)MERV7,MERV8
Media: the filter mats are Made of high performance polyester fibers with durable thermal bonding Increment structure, large dust capacity,Not silicon

Structural Description Design Description


Differential pressure identification: By using a differential pressure system to identify whether the filter surface needs to be replaced, it avoids the waste of filter material and resources caused by human operation errors, and ensures that the filter achieves optimal filtration efficiency and economic operation mode during operation;
Dual control of time/pressure difference: avoid excessive rolling up of clean filter material, which may cause waste;
Filter media alarm indication: When a roll of filter media is almost used up, the indicator light prompts to replace it with a new roll of filter media;
Flexible module assembly: This device can be used independently as a single unit or assembled with multiple units to meet the needs of places with large ventilation areas;
Automatic Renewable Media Controlled System
This is the corn design of Autoroll-Filter. The pressurize detector system controlled the renewable media without any human decision judgments. Thus ,minimize human error decision on renewable media and power consumption to ensure the finest efficiency rate and economic operation during services.

Working principle
A new roll of filter material is installed on the filter box of the automatic winding filter. When high air volume and high concentration dusty air is introduced by external force and passes through the winding filter, the initial resistance of the filter gradually increases with the increase of filtered dust. When the resistance of the filter rises to the design final value, the pressure difference switch is activated, and its switch signal is input into the control program to automatically start the motor. The motor runs to drive the lower filter material spool to rotate, thereby winding up the dirty filter material and replacing it with clean filter material on the filtering surface. Until the entire roll of filter material is used up, by changing the position of the handle, the limit switch in the upper filter material box will be disconnected, and the filter material alarm indicator light (red light) will light up to indicate the need to replace a new roll of filter material.
The controlled system has a pre-set value for final resistance . When the pressure value is equivalent or larger than preset value,the logo control will auto-matically roll the renewable media. The dirty media go downward and a clean media will take over.

Application Applications


The first stage pre filtration section of industrial ventilation and air conditioning ventilation systems
A working environment with high dust content that requires frequent replacement of filter media
The primary filter of industrial-grade ventilation systems
High dust content,Need frequent replacement filter places

Performance Features


Material Table

framework

Frame

Cold rolled sheet metal spraying treatment

Cold roll steel ,powder coated surface

Upper filter box

Top Media

Sealed structure ensures that clean filter material will not be contaminated

Seal tightly to ensure the media will not be contaminated

Bottom filter roll

Bottom Media Support

Dirty filter material on the winding filter surface

To ensure the dirty media will be rolled back properly after used

Electrical Control Cabinet

Control box

Logo/pcbControl device and control circuit

Pressure differential switch

Motor transmission device

Motor

Applicable voltageVoltage50Hz: 110V,115V,200V,220V,230V)

(60Hz:110V,220V,240V)

powerPower 200W(1/4HP)

filter media

Media

Synthetic fiber, thickness10mm,15M/roll

Polyester media in roll form

Environmental temperature for use

Operating Temperature

-10˚C~+40˚C(Continuosly operate)

Total width of filterNominal Widthrated air volume(m³/h)Rated Air Flow(m³/h)

Feet (millimeters)ff(mm)Filter total height inches (millimeters)Norminal Height ff(mm)


5(1524)

6(1829)

7(2134)

8(2438)

9(2743)

10(3048)

11(3353)

12(3658)

13(3962)

14(3962)

15(4572)

03914

6413

8702

10991

13280

15569

17858

20147

22436

24725

207014

29303

041219

8756

11881

15006

18131

21256

24381

27506

30631

33756

36881

40007

051524

11099

15060

19021

22982

26943

30905

34866

38827

42788

46749

50711

061829

13441

18239

23036

27833

32631

37428

42225

47022

51820

56617

61415

072134

15784

21417

27051

32684

38318

43951

49585

55218

60852

66485

72119

082438

18127

24596

31066

37535

44005

50475

56944

63414

69883

76353

82823

092743

20469

27775

25081

42386

49692

56998

64304

71609

78915

86221

93527

103048

22812

30954

39096

47238

55379

63521

71663

79805

87947

96088

104231

113353

25155

34133

43111

52089

61067

70045

79022

88000

96978

105965

114935

123658

27497

37312

47126

56940

66754

76568

86382

96196

106010

115824

12539

133962

29840

40490

51141

61791

72441

83091

93741

104392

115042

125692

136343

144267

32183

43669

55156

66642

78128

89615

101101

112587

124073

135560

147047

154572

34526

46848

59170

71493

83815

96138

108460

120783

133105

145428

157751

164877

36868

50027

63185

76344

89503

102661

115820

128978

142137

155295

168454

175182

39211

53206

67200

81195

95190

109184

123179

137174

151169

165163

179158

185486

41554

56384

71215

86046

100877

115708

130594

145369

160200

175031

189862

195791

43896

59563

75230

90897

106564

122231

137898

153565

169232

184899

200566

206090

46239

62742

79245

95748

112251

128754

145258

161760

178264

194746

211270

216401

48582

95921

83260

100599

117939

135278

152617

169956

187295

204635

221974

226706

50924

69100

87275

105450

123626

141801

159976

178152

196327

214503

232678

237010

53267

72279

91290

110302

129313

148324

167336

186348

205359

224370

243382

247315

55610

75457

95305

115353

135000

154848

174695

194543

214391

234238

254086

Note: 1. The air volume value calculated when the above wind speed is at 2.5m/s
2. When the width is greater than 06ff, multiple units are assembled together

Note:1、Recommended final resistance is 250Pa
2、Nominal air volume is 2.5m/s

1. In case of changes in specifications or structure, the new data provided by our company shall prevail
2. Our company accepts orders for non-standard specifications

1. If you meet specifications, structural changes, the company provides the newest data shall prevail
2.We accept the orders of non-standard specifications