Welcome Customer !

Membership

Help

Ningbo Aichun Biotechnology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Ningbo Aichun Biotechnology Co., Ltd

  • E-mail

    dawei.zhao@aichrom.com

  • Phone

    15210979260

  • Address

    No.1 Zhongguancun North Second Street, Haidian District, Beijing

Contact Now

SPR molecular interactor

NegotiableUpdate on 02/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The AiSPR-96 SPR molecular interactor has a wide wavelength range, meeting various application needs such as molecular interaction, kinetics, protein quantification, enzyme activity determination, ELISA experiments, and cell detection.
Product Details

AiSPR-96SPR molecular interactorMain Features

1. 96 flux can meet large-scale detection needs, and can also be used for local hole selection or jump hole detection, making it flexible to use

2. 8-channel light absorption can be quickly measured with high accuracy and good repeatability

3. Wide wavelength range, meeting various application needs such as molecular interaction, kinetics, protein quantification, enzyme activity determination, ELISA experiments, cell detection, etc

4. A supporting software analysis platform that enables one-stop data processing

5. Compact and portable instrument structure design

<strong>AiSPR-96分子互作仪</strong>应用场景.png


As a label free biomolecule interaction analyzer, AiSPR-96 no longer limits the molecular weight of organic compounds. You can analyze sensitive or rare samples, accurately obtain data on extremely fast binding or very slow dissociation, and reliably reveal small differences in kinetics.

AiSPR-96 is a 96 well plate biomolecule interaction analyzer based on SPR technology, which can achieve real-time analysis without labeling, providing you with high-quality kinetic, affinity, antibody screening, and concentration determination information. AiSPR-96 can accurately distinguish concentration differences at the picomolar level, allowing you to directly measure intermolecular interactions in the natural state of the sample without the need for some inferior alternative methods. AiSPR-96 provides valuable information on intermolecular interactions between biomolecules for various application fields, from basic scientific research, small molecule and biopharmaceutical development, to vaccine development and quality control.

Detailed analysis of intermolecular interactions is not simply described as the strength of affinity. By parsing affinity into real-time kinetic data, we can gain a deeper understanding of biological phenomena and make the connection between intermolecular interactions and their functions clearer.

AiSPR-96SPR molecular interactorThe extended dynamic space provided brings you tangible benefits, as you can obtain high-quality information related to interactions between biomolecules. Even for highly dynamic interactions, such as extremely fast binding processes and extremely slow dissociation processes, you can confidently measure them. You can accurately determine the true dissociation rate of antibody complexes with strong affinity, which is crucial for optimizing drug efficacy. You may also be able to capture subtle behavioral differences between rapidly binding molecules, which will help you screen for better drugs, especially when the physiological activity concentration is low after drug use.

<strong>AiSPR-96分子互作仪</strong>2.png

Basic Parameters


Size (length x depth x height)

370 × 210 × 140 mm

Weight (excluding computer)

2.8 kg

power supply

100–240 VAC, 50/60 Hz

interface

USB


performance parameters

Detection Principle

Surface Plasmon Resonance (SPR) Technology

Detection Application

Dynamics/affinity characterization, dynamics/affinity screening, single cycle dynamics, small molecule interaction analysis, fragment drug screening, epitope identification, pairing screening, immunogenicity, quantitative analysis, thermodynamics, ELISA, and enzyme-linked immunosorbent assay detection functions, etc

Sample Type

Buffer solution containing DMSO, purified samples, plasma and serum, cell supernatant, lysis buffer, small molecule candidate drugs, high molecular weight protein antibodies, peptides, DNA, RNA, polysaccharides, lipids, cells, and viruses, etc

Optical channel

8 fiber optic detection channels

flux

96, up to 8 parallel determinations

refractive index

1.33-1.40

sample volume

2 μL - 200 μL

Oscillation speed

200-1200 rpm

Minimum detection limit

200 Da

Detection Time

Conduct affinity testing on 8 samples for less than 10 minutes; Dynamic screening can simultaneously test up to 96 samples, with a minimum analysis time of 5 minutes. The data is sorted according to the size of the combined signal

Baseline noise (RMS)

< 0.1 RU

baseline drift

< 0.5 RU/min

Sample size for testing

Up to 96 samples can be measured simultaneously

Concentration detection range

0.05-1000 μg/mL

Testing time (typical)

96 samples can be quantitatively tested for human IgG in just 5 minutes

The data shows

Display real-time dynamics combined with curve graphs, fitting result graphs, concentration data analysis, including calibration curves and output of concentration data lists, kinetic data lists, epitope identification graphs, bar charts, etc

Export file

EXCEL、TXT

Chip sensor

Item Number

Ci-11

Ci-12

Ci-13

Ci-14

Ci-15

Ci-16

Ci-17

Ci-18

Ci-19

Ci-20

Ci-21

Ci-22

Ci-23

Ci-24

Ci-25

Ci-26

Ci-27

Ci-28

Ci-29

Ci-30

Ci-31

Ci-32

Ci-33

Ci-34

Ci-35

Ci-36

Ci-01

Ci-02

Ci-03

Ci-04

name

Protein A (ProA) Sensor (Long lasting)

Protein A (ProA) sensor (universal type)

Protein A (ProA) Sensor (High Sensitivity Type)

Protein G (ProG) sensor

Protein L (ProL) sensor

NTA chip sensor

Anti glutathione S-transferase (GST) sensor

Streptomycin (SA) sensor

Super Streptomycin Affinity (SSA) Sensor

Anti human Fc fragment (AHC) sensor

Anti mouse Fc fragment (AMC) sensor

Anti His tagged antibody sensor

NanosPR sensor chip (high sensitivity type)

NanosPR Biochip (High Adsorption Type)

NanosPR Biochip (High Stability)

NA sensor

Carboxylation sensor

Amination sensor

Lipophilic biosensor

Anti human Fab-CH1 second-generation (FAB2G) sensor

High precision streptavidin (SAX) sensor

High precision streptavidin 2.0 (SAX2) sensor

Anti human IgG (AHQ) capture sensor

Anti His (HIS2) Capture Sensor

Anti His (HIS1K) Capture Sensor

Anti mouse IgG quantification (AMQ) capture sensor

Human Fab Capture Kit

Mouse Antibody Capture Kit

His Capture Kit