Protein Purifier

NegotiableUpdate on 02/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The PPS-HD protein purifier is divided into three versions: PPS-10HD, designed specifically for purification tasks of scientific research users; PPS-100HD, Very suitable for optimizing resource utilization and improving productivity in large-scale preparation and purification; PPS-PilotHD, The system has a wide range of work flow and pressure, suitable for research and development of different scales, large-scale research, as well as small-scale and pilot scale production. PPS-HD supports multiple chromatography techniques and meets the automation requirements required to provide high purity.
Product Details

PPS-HD protein purifierOverview

PPS-HD is a modular protein purification system that facilitates reliable and stable purification. The system consists of a PPS-HD host and PPSN software. The system adopts a modular design, with all valves, detectors, and chromatography columns installed on the front side of the system, making it easy for operators to operate the PPS-HD instrument (Figure 1). Additional components such as valves, detectors, and sensors from various optional modules can be easily added to available locations. There are multiple guide rails on the front and side of the instrument for connecting the chromatography column bracket and equipment. The buffer tray at the top of the instrument provides a convenient storage area for containers and bottles. The instrument control panel displays the system status in real-time.

The lighter weight of the system makes it easier to place on laboratory workbenches, and the smaller system size makes it easy to install in standard refrigerators for purifying unstable samples. PPS-HD comes standard with two high-performance system pumps, a system pressure detector for column protection, a mixer, an injection valve, a UV detector, and a conductivity detector. PPS-HD has multiple optional modules that offer multiple possibilities. The design of the system flow path aims to minimize bandwidth effects, and the wetting materials used in the flow path are biocompatible and can tolerate commonly used solvents. The front of the instrument is designed with reserved module positions for installing optional valves and detectors to achieve flexible flow path configuration. Examples of PPS-HD system configuration flow paths are shown in Figures 2 and 3.

PPSN software allows for quick and easy creation of methods, control of operations, and analysis of results. PPSN software does not require professional programming skills, and the creation of tomographic methods is very simple.

The PPS-HD standard components and optional components will be detailed in the following chapters.


Figure 1 PPS-HD instrument host


Figure 2PPS-HD protein purification systemStandard configuration flow diagram


Figure 3PPS-HD protein purification system high configuration flow path diagram





system parameters


control system

PPSN

Dimensions (width x height x depth)

482 × 661 × 432 mm

Weight (excluding computer, sample pump, component collector)

The heaviest weight is 65 kg

power supply

100–240 V, ~50–60 Hz

power consumption

300 VA

Shell protection level

IP 21


System pump

Pump type

Measurement type plunger pump

flow rate range

PPS-10HD: 0.001 to 10 mL/min

PPS-100HD: 0.01 to 100 mL/min

PPS-PilotHD: 1 to 400 mL/min

Flow rate specification

PPS-10HDAccuracy: ± 0.5%

Precision: RSD<0.5% (conditions: 0.1 to 10 mL/min,<3 MPa, 0.8 to 2 cP)

PPS-100HDAccuracy: ± 0.5%

Precision: RSD<0.5% (conditions: 1.0 to 100 mL/min,<3 MPa, 0.8 to 2 cP)

PPS-PilotHDAccuracy: ± 1%

Precision: RSD<1% (conditions: 4 to 400 mL/min,<1 MPa, 0.8 to 2 cP)

pressure range

PPS-10HD: 0 to 20 MPa

PPS-100HD: 0 to 10 MPa

PPS-PilotHD: 0 to 2 MPa

Viscosity range

PPS-10HD: 0.35 to 10 cP

PPS-100HD: 0.35 to 5 cP

PPS-PilotHD: 0.35 to 5 cP


Sample pump

Pump type

Measurement type plunger pump

Dimensions (width x height x depth)

215 × 210 × 370 mm

weight

11 kg

flow rate range

0.01 Up to 100 mL/min

Flow rate specification

Accuracy: ± 0.5%

Precision: RSD<0.5% (conditions: 0.1 to 100 mL/min,<3 MPa, 0.8 to 3 cP)

pressure range

0 Up to 10 MPa

Viscosity range

0.35 Up to 5 cP


mixer

Mixing principle

Chamber with magnetic stirrer

Mixing tank capacity

PPS-10HD: 1 (standard) or 2 mL

PPS-100HD 150: 2 (standard) or 5 mL

PPS-PilotHD5 mL (standard), other volumes can be customized

Gradient flow velocity range

PPS-10HD: 0.1 to 10 mL/min

PPS-100HD: 0.5 to 100 mL/min

PPS-PilotHD: 2.0 to 400 mL/min

Gradient synthesis accuracy

PPS-10HD± 0.6% (conditions: 5% to 95% B, 0.6 to 10 mL/min, 0.2 to 2 MPa, 0.8 to 2 cP)

PPS-100HD± 0.8% (conditions: 5% to 95% B, 2 to 100 mL/min, 0.2 to 2 MPa, 0.8 to 2 cP)

PPS-PilotHD± 2% (conditions: 5% to 95% B, 4.0 to 400 mL/min, 0.2 to 1 MPa, 0.8 to 2 cP)


valve

type

Rotary valve

number of valves

Up to 6

function

Standard configuration: Injection valve

Optional: Inlet selector valve, backwash valve, chromatography column selector valve, outlet selector valve


pressure sensor

Location of sensors

Standard configuration: After the system pump

Optional: after sample pump, before chromatography column, after chromatography column

scope

0 Up to 20 MPa

accuracy

±0.02 MPaOr ± 2%, whichever is greater



Inlet valve

entranceA

12 or 6 entrances

entranceB

12 or 6 entrances


outlet valve

export quantity

6

Volume of component collection

0.01Up to 100000 mL

Delay volume (UV outlet valve)

300 μL(Standard piping)


UV detector

wavelength range

DET-HD-L:280 nm

DET-HD-MStandard configuration: 200~400 nm, optional 200~800 nm. Step size: 1 nm, simultaneous detection of three wavelengths

liquidity pool

Standard configuration: Optical path length of 2 mm, pool volume of 5 μ l

Optional: Optical path length of 5mm, pool volume of 8 μ l

resolution

0.01 mAU

linear

± 2% within the range of 0-2AU

drift

1x10-3AU/H

2 mmAt 280 nm in the flow cell

noise

< 0.1 mAU


Lamp working life

LED> 10000hour

Deuterium lamp>2000 hours


Conductivity detector

Reading range

0.00mS/cmUp to 1000.00mS/cm

accuracy

±0.01mS/cmOr ± 2%, whichever is greater, (within 0.3 to 300 mS/cm)

work pressure

0Up to 5 MPa

Flow pool volume

Standard configuration: 24 μ L


Temperature detector

Reading range

0°Cto99°C

precision

±1°C, Range of 4 ° C and 45 ° Cinside


pHdetector

Reading range

0.00 Until 14:00

accuracy

±0.1 pHUnit, within the pH range of 2 to 12

work pressure

0To 0.5 MPa

Flow pool volume

Standard configuration: 120 μ L


Component Collector

Number of components

Up to 100

Collection tube type

100(15 mL centrifuge tube)

25(50 mL centrifuge tube)

4A 250 mL triangular flask

Component volume

0.1Up to 250 mL

Anti overflow mode

Clamp valve control

Dimensions (width x height x depth)

370 × 305 × 425 mm

Delay volume

500 μL(Standard piping)


Bubble sensor

Number of sensors

up to 3

sensor position

Before the system pump

Before the injection valve

Sensing principle

ultrasound

Order Information

system

Product Code

product

99018224

PPS-10HD L

99018226

PPS-10HD M

99016665

PPS-100HD L

99016694

PPS-100HD M

99014325

PPS-PilotHD L

99014328

PPS-PilotHD M



System accessories and modules

pipeline

Product Code

product

99024238

1/16PTFE tube

99021583

1/16 PEEKTube inner diameter 1mm

99022095

1/16 PEEKTube inner diameter 0.25mm

99021368

1/16 PEEKTube inner diameter 0.5mm

99021253

1/16 PEEKTube inner diameter 0.75mm

99022116

1/8PTFE tube

99020392

Pipe cutter (with blade)

99020407

Titanium alloy inlet filter

99020408

UHMWPEInlet filter


joint

productcode

product

99031252

10-32Long plug

99031253

10-32Short plug

99031255

10-32Long hand twisted connector

99031256

10-32Hand twisted connector

99032707

5/16-24, 1/16 '' pipe joint

99032706

5/16-24, 1/16 '' pipe clamp sleeve

99032117

5/16-24, 1/8 '' pipe joint

99032118

5/16-24, 1/8 '' pipe clamp sleeve

99031249

5/16-24, 3/16 '' pipe joint

99031248

5/16-24, 3/16 '' pipe clamp sleeve

99035801

M6 FTurn 10-32 M connector

99031257

10-32 FConvert M6 M connector

99032776

5/16-20 FConvert M6 M connector

99030339

10-32through

99031332

Pump cleaning solution connector

99031251

10-32 MSyringe connector


+

Injection ring

productcode

product

99041398

100uLQuantitative ring

99041399

500uLQuantitative ring

99041401

1mLQuantitative ring

99041402

2mLQuantitative ring

99044053

5mLQuantitative ring

99046124

10mLQuantitative ring


pump

productcode

product

99052075

PPS-10HDPlunger rod

99052077

PPS-10HDsealing ring

99051213

PPS-100HDPlunger rod

99051204

PPS-100HDsealing ring

99051890

1 mLMixing pool

99051891

2 mLMixing pool

99051892

5 mLMixing pool

99052135

0.2 MPaReverse pressure valve

99051963

0.4 MPaReverse pressure valve

99052123

Bubble sensor


detector

Product Code

product

99061110

2 mmliquidity pool

99061111

5mmliquidity pool

99062933

Tungsten lamp

99062934

Deuterium lamp

99062941

pHelectrode


valve

Product Code

product

99071480

Two inlet solenoid valves

99070902

6Position inlet valve

99070905

Injection valve

99070906

Recoil valve

99070907

Single column valve

99070910

Five column valve

99070915

outlet valve