Product Introduction
SGSY 1100Enzyme linked immunosorbent assay analyzer,Production and verification under strictly controlled conditions,Used for qualitative and quantitative analysis of biomolecules (such as proteins, nucleic acids) or cell activity and other samples in microplates by detecting light signalsIt has the advantages of beautiful appearance, small size, low power consumption, and easy use, and can be used forAnalyze antigen antibody reactions, quantify or qualitatively determine substance concentrations, and achieve rapid qualitative and quantitative analysis of biomolecules (such as proteins, antibodies, viruses).Precise control, good experimental reproducibility,Can perform high-throughput biochemical analysis and immune testing(ELISA)Cell experiments and drug screening are suitable for various research, development, and testing laboratories, and can be used for various types of testing projects, such as veterinary drug residues, pesticide residues, hormones, antibiotics, fungal toxins, food additives, various pathogens, etc,And it can be expanded to applications in more industries and needs,Widely used in fields such as inspection, biological research, biomedicine, drug development, screening, food safety, environmental monitoring, and quality control,Meet the high-performance requirements of high-level laboratories or testing institutions, as well as micro testing.
Product Features:
• Optimized color graphical interface, Chinese operating system, supports mouse, keyboard, and multiple input methods;
• 10.4inchFull touch color control screen,Easy and fast to use, can easily edit, save, and run programs;
• exquisiteUIInterface,clear and intuitiveOptimize operational processes and interaction logic for higher work efficiency
• Massive storage, at least capable of storing100Wanban(96)Test data and500A programming project that supports data backup, recovery, and merging;
• full screen display96Visual layout operation interface for holes, with layout and save import functions, greatly improving the testing efficiency of commonly used projects;
• Automatic zeroing can be performed in both single wavelength and dual wavelength testing modes;
• Automatically store standard curves and make corrections to them. Test results are automatically calculated and judged without the need for secondary conversion;
• Intelligent calculation of test results ensures their accuracy and reliability, and can automatically trigger alarms;
• Built in embedded system allows for operation, storage, and printing without the need for an external computer;
• Can be performed on the same board24Different projects can be tested with display differentiation, and qualitative and quantitative projects can be tested on the same board
• Template function, fixed detection work, can greatly simplify the workload of operators;
• Intelligent switch for light source, extending its lifespan;
• Comprehensive and comprehensive quality control functions, includingwestguardMulti rule quality control, instant method quality control, and other various quality control charts and parameter calculations, with quality control alarm function;
• Provide multiple printing methods and various forms of Chinese reports,And can customize various reports;
• You can choose absorbanceCut-OffQualitative calculation, single point calibration, line regression, linear regression, exponential regression, logarithmic regression, double logarithmic regressionlog-logitCalculation methods such as power regression, four parameter regression, and enzyme inhibition rate;
• Specialized system maintenance menu, automatically determines the current status and performance indicators of the instrument, and can print relevant data;
• OptionalPCWorkstation with networked functionality, customizable for uploading.
Technical Specifications:
• Wavelength range:330-1100nm
• Filter configuration:10A filter position,standard configuration405、450、492The630nmStandard filter, optional6Customized wavelength filter;
• Absorption range:0.000―4.000A
• Number of optical channels:8Channel optical path detection, set up an independent reference channel
• Stability of indication: ≤±0.002AOr ≤0.5%T/10min
• Indication error (accuracy): ≤±0.005AOr ±0.2%T
• Repeatability: ≤0.2%Or ≤0.2%T
• Sensitivity: ≥0.01(L/mg)
• Channel difference: ≤0.01A
• Wavelength indication error: ±1nm
• Half width: ≤8nm
• Peak transmittance: ≥35%
• Resolution:0.001A(Display),0.0001A(Internal calculation)
• Reading speed: Single wavelength ≤3second/96Hole, dual wavelength ≤6second/96Kong
• Vibration board function: adjustable speed and time
• Calculation modes: qualitative, quantitative, calibration curve equation
• Light source type: halogen tungsten lamp
• Flat noodles type: standard96Hole or other types of enzyme label plate and strip
• Applicable hole type: flat bottomUType andVtype
• Display mode:10.4Inch color LCD display screen
• Input method: Touch screen input, optional mouse and keyboard
• Printing: Built in thermal printer, can be connected to an external printer
• Interface:USB口、RS232Serial port, printer port, keyboard and mouse interface
• Usage environment: Temperature5-40℃; humidity15%-80%
• Power supply voltage220V±10%,50/60Hz
• volume470mm×350mm×210mm(Length x Width x Height)
• Weight:11.5Kg
Ordering information:
name |
Specifications |
Remarks |
market price |
Current selling price |
SGSY 1100Enzyme linked immunosorbent assay analyzer |
wavelength range330-1100nm |
havePCworkstation |
53800.00 |
45000.00 |
SGSY 1100Enzyme linked immunosorbent assay analyzer |
wavelength range330-1100nm |
nonePCworkstation |
48800.00 |
41500.00 |
Optional filter |
Multiple filter specifications to choose from |
Wavelength optional |
1500.00 |
1200.00 |