SF6 new gas analysis gas chromatograph

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

SF6 decomposition product helium ionization gas chromatograph, GC-6600 SF6 new gas analysis gas chromatograph. This scheme uses gas chromatography to separate and detect air, carbon tetrafluoride, hexafluoroethane, and octafluoropropane in sulfur hexafluoride new gas one by one. The gas chromatograph is equipped with a combination of FID and TCD dual detectors, and adopts an automatic ten way valve and automatic six way valve combination injection cutting method to allow the sample to enter different chromatographic columns for analysis and detection of peak areas. Air and carbon tetrafluoride peak in the TCD channel, while hexafluoroethane and octafluoropropane peak in the FID channel. The calculation is quantitatively calculated using the standard gas external standard method.

Product Details

Product Description:

SF6 gas is mainly used in the power industry. SF6 gas is used for insulation and/or arc extinguishing in four types of electrical equipment; SF6 circuit breakers and GIS (referring to SF6 enclosed composite electrical equipment, internationally known as "Gas Insulated Switchgear"), SF6 load switchgear, SF6 insulated transmission pipelines, SF6 transformers, and SF6 insulated substations. 80% is used for high and medium voltage electrical equipment.Before injecting sulfur hexafluoride gas into power equipment, the testing department needs to analyze the injected sulfur hexafluoride to determine whether the new gas meets the standard requirements,GC-6600 SF6 new gas analysis gas chromatograph mainly analyzes air, carbon tetrafluoride, hexafluoroethane, and octafluoropropane.

Reference standard:

GB/T12022-2014《Industrial sulfur hexafluoride

How to translate18867-2014GB/T《

Electronic industry gas sulfur hexafluorideHow to translate

DL/T 1366-2014

  • 《
  • Sulfur hexafluoride for power equipment
  • How to translate
  • Instrument configuration:
  • Gas chromatography host

FID detector

TCD detector

Automatic sampling and switching systemchromatographic column

Chromatography workstationStandard gasInstrument features:1. Main functional requirements

★1.1 New networked control and transmission to achieve real-time monitoring and data collection by multiple people:

Equipped with a 10/100M adaptive Ethernet communication interface and built-in IP protocol stack, the instrument's PI address can be set to remotely access the chromatograph through the network,The instrument can realize remote control of the chromatograph and data transmission of the collected spectrogram through the enterprise internal LAN and the Internet;instrumentThree independent connection processes are designed internally, which can be connected to the local processing (laboratory technician), unit supervisor (team leader), and superior supervisor (special supervisor, chief engineer, etc.) through the Internet, which can facilitate multiple people to monitor the operation of the instrument and analyze the data results in real time, and improve the cooperation and timeliness of work.★1.2 Multiple workstations control, enabling one computer to simultaneously monitor N gas chromatographs

The GC-6600-F instrument is equipped withNETChrom

TM

Workstation, capable of supporting multiple chromatography instruments to simultaneously process and control data, reaching the industry's highest levelEffectively solved the problem of too many computers in the laboratory and released experimental space.

The analysis parameters of the sulfur hexafluoride analyzer, including carrier gas pressure, sample pressure, temperature, etc., are set or displayed through a workstation, which is easy to operate and provides real-time monitoring of the analysis conditions.

★

1.3 Adopting central cutting technology to achieve high automation of the instrument:

Adopting a dual quantitative tube injection and purging technology with 2 imported automatic drive valves and 3 chromatographic columns, the injection, switching, column selection, and reflux processes are automatically controlled through the time program set by the workstation. One injection can complete the separation, selection, and detection of complex samples.★

1.4 Digital electronic zeroing technology enhances the anti-interference ability of instruments:

The detector signal zeroing adopts electronic zeroing technology, using high-precision digital circuits for base current compensation to achieve electronic adjustment of output signal level, reducing parasitic parameters and thus having strong anti-interference ability.

1.5 Automatic gas cut-off protection function to ensure the safe operation of the detectorEquipped with intelligent gas cut-off protection function, when the carrier gas pressure is below the safety threshold, the system will automatically cut off the detector voltage and the chromatograph will automatically cool down to protect the detector and chromatographic column from damage.★

1.6 Industrial 5.7-inch color screen, Chinese LCD display2The display window adopts a 5.7-inch industrial color LCD screen design, which displays more comprehensive information, the interface operation is more reasonable, the display is intuitive, and the operation is convenient; The spectrum display function abandons the fragile and low-end PVC leather buttons and adopts plastic mold buttons, which have a good hand feel and are durable.21.7 Standard gas4The instrument quantification adopts the mixed standard external standard method. One bottle of mixed standard gas should contain at least the following components, and the range of standard gas components should be controlled within2200~600ppm6between:3Oxygen (O)8)Nitrogen (N)

)Carbon tetrafluoride (CF)

)Hexafluoroethane (C)

  • F
  • )Octafluoropropane (C)
  • F
  • )

2. Technical indicators2.1 Technical Performance:

  • Analysis cycle:<18 minutes3Maximum error:<1%10-12Stable time:<30 minutesWorking environment: -10~50 ℃2.2
  • Hydrogen flame ionization detector (FID)10-14Detection limit: Mt ≤
  • ×10-13G/s (n-hexadecane)
  • -Isooctane solution106
  • );

Noise: ≤ 5 ×ADrift: ≤ 1 ×

  • A/30min
  • Linear range: ≥100It has automatic ignition function upon startup and automatic ignition upon shutdown to prevent hydrogen leakage after accidental shutdown.2.3Thermal conductivity detector (TCD):Self protection function for gas interruption, protecting the thermal conductivity pool.Sensitivity: S ≥00mV•ml/mg
  • (High sensitivity)10(
  • Benzene toluene solution)(Magnify by 2, 4, or 8 times to choose from
  • )Noise: ≤104

μVBaseline drift: ≤ 30 μ m

  • V
  • /30min
  • Linear range:
  • ≥
  • ★
  • 2.4 Temperature control indicators:
  • Temperature control range: 4 ℃ -450 ℃ at room temperature

Temperature control accuracy: ± 0.1 ℃

  • Temperature controlled area: 8 channels
  • Program heating order: 8 orders
  • Program heating rate: 0.1 ℃ -80 ℃
  • Cooling rate: within 7 minutes (400 ℃ -50 ℃)

Detector: 4 ℃ -450 ℃ at room temperature with an accuracy of ± 0.1 ℃2.5. Other parameters: size, weight, power supply

Dimensions: Width 572mm, Height 465mm, Depth 552mm

  • Weight:~50kg
  • Power supply: 220V ± 22V, 50Hz Power: ≥ 2kW
  • Ethernet: IEEE802.3
  • 3
  • Networked NETChromTM Workstation:3.1 Workstation performance:The networked workstation enables remote control of multiple chromatography instruments, allowing you to control the global GC-6600 gas chromatograph from your deskFour channel acquisition function, not limited to acquisition with only two detectors;
  • Real time display of eight temperature control channels, allowing for the setting of temperature parameters and protection values for various parts at any time;Display the pressure and flow rate of each gas path, real-time understanding of the pressure and flow rate of the injector, detector, sample gas, and total chromatographic gas;settingThe pillar boxProgram heating program and real-time display of program heating status;settingEight roadsExternal events,Time can be set freelyautomaticCompleted: Valve
  • Injection
  • Multiple valve selection

3.、

  • Automatic valvecutting.3Various external controls such as liquid automatic sampler, etc;
  • Automatic collection of injection spectra;
  • The storage analysis program completes functions such as one click startup, automatic sampling, spectrum analysis, and sample data saving;
  • 2. Hardware performance:
  • communication interface
  • Ethernet IEEE8026
  • Connect the network cable directly;
  • High precision: 24 bit high-precision A/D
  • Resolution: ± 1UV

3.Input voltage range: -5mv to+1vSampling frequency: up to 20 times per secondDynamic range: 10

  • Integral sensitivity: 1 μ v · sec

Linearity:<± 0.1%.

  • Reproducibility: 0.06%.

3

  • Workstation features

:

  • Laboratory management function

Supervisors and managers can manage chromatographic state machine data in real-time through the network, and can set up a computer as a server to centrally store all data for data management to prevent the loss of raw data.

  • networked

The connection port is a LAN interface, eliminating the drawbacks of RS232 data interface being prone to crashes and short distance. The high-speed transmission of data through Ethernet cables can enable one computer to control up to 253 chromatography instruments.

  • Total reversal control

All parameters related to analysis can be set on the workstation to achieve * reverse control.

  • Intelligent Points

All integration events and standard curve files are saved in the method file, which only needs to be set once. Irregular peaks will also be fully automatically integrated, saving the trouble of manual integration and eliminating manual integration errors.