Introduction to ROHS/Coating/Alloy Spectrometer: X-rays have the characteristic of different energies. Fluorescence X-rays from the sample are sequentially detected to obtain a series of pulses with amplitudes proportional to photon energy. After amplification by an amplifier, they are sent to a multi-channel pulse analyzer. Count the number of pulses according to the magnitude of the pulse amplitude, which can be scaled using the energy of X-rays to obtain the distribution curve of the counting rate as a function of photon energy, known as the X-ray energy spectrum.

Product Details

Supply RoHS/Coating/Alloy Spectrometer

rohs/镀层/合金光谱仪

合金光谱仪

镀层光谱仪

rohs光谱仪

RoHS/Coating/Alloy Spectrometer Product Parameters

Number

Product Specifications

Remarks

Product Specifications

Product model: BXR-606

Product Name:Energy dispersionXFluorescence Spectrometer

Analysis principle

Energy dispersive X-ray fluorescence analysis method

analyze elements

-

Analyzable stainless steelCopper alloys, zinc alloys, tin lead alloys, precious metal analysis, etc.

quantitative testingROHSLead in halogens(Pb)Mercury(Hg)Cadmium(Cd)Chromium(Cr)Polybrominated biphenyls(PBB)And polybrominated diphenyl ethers(PBDE)Total Bromine in,Bromine in halogens(Br)Chlorine(Cl).

Can analyze the most5Layered coating, capable of analyzing up to one element at a time24plant

working conditions

Working temperature: 18-22℃

Relative humidity: 40% -60%

Power supply: AC 220 V±10 %、50/60 Hz

Measurement conditions: atmospheric environment

technical indicators

Detection limit: Pb/Cd/Cr/Hg/Br/Cl≦2ppm

Test sample time: adjustable from 50-300 seconds

Test content range: 1ppm-99.99%

The dynamic range of analysis and measurement is wide, ranging from 0.005 μ m to 50 μ m

Sample shape: any size, any irregular shape

Sample type: Plastic/metal/film/powder/Liquid

X-ray tube:

Tube voltage/0-50 kVTube current/maximum11000 MA,Maximum power: 50 W, filament voltage: 2.0V, filament current: 1.7 A, ray extraction angle: 12 ° Target material: tungsten target, beryllium window thickness: 400um, over temperature overload protection, automatically enters standby mode when not in operation to extend service life.

Illumination diameter: collimator 8mm \ \ 2mm \ \ 1mm \ \ 0.5mm

Detector:

Amptek Si PIN high-sensitivity detector from the United States, optimal resolution: 149 ± 5eV.

AmericaSpellmanhigh-voltage power supply:

Input voltage: DC+24V ± 10%, input current: 4.25A (maximum), output voltage: 0-50KV&1mA, maximum power: 50W, voltage regulation rate: 0.01% (from no-load to full load)

Current regulation rate: 0.01% (from no-load to full load), ripple voltage: Under the premise of outputting rated voltage, the peak value of ripple voltage is 0.25% of the highest output voltage, and the stability after 8 hours is ≤ 0.05%.

Cooling system:

There are multiple heat dissipation holes at the front and rear of the body for heat dissipation. There are three fans inside the body for air cooling, and the X-ray tubes are coated with high-temperature heat reducing resin and wrapped in heat dissipation fins. There is also one fan for blowing and dissipating heat.

Radiation protection system:

A combination of soft and hard radiation protection design, triple treatment: special radiation treatment for the X-ray tube, double-layer lead skin wrapping for the sample cover, software radiation warning (when personnel accidentally open the sample chamber during instrument operation, the instrument will automatically shut down to ensure operator safety), obtaining the national radiation safety license, and radiation dose below the national standard.

Filter: Eight new types of filters with automatic selection settings

Sample monitoring system:

30 times15 million pixel colorCCD camera, in the software testing interface, can observe the sample status in real time and adjust the sample position by micro movement before placing the sample for testing. After the sample testing is completed, the pattern is clearly presented in the testing report.

Software system:

Quantitative analysis and calculation, using theoretical Alpha coefficient method (NBS-GSC method), integrated FP, and empirical coefficient method, targetingRoHSHalogen-free element(PbCdHgBrCrCl)Accurate testing. Multi language operation interface, simple operation, one click design, can generate various humanized customized reports, and can automatically output report formats such as PDF, EXCEL, etc.

Rated power: 0.35kW

Weight: 50Kg

Dimensions: 650 (W)×450(D)×450(H)mm

Sample cavity size: 350 (W)×300(D)×150 (H) mm, the large sample cover can be opened for testing.

Standard Configuration

Amptek Si PIN detector set:

A tungsten target special anti radiation treatment side window X-ray tube

AmericaSpellmanOne high-voltage power supply

Fully enclosed lead plate dual sample chamber

A high-precision CCD camera

A set of Alpha coefficient method (NBS-GSC method), integrated FP, and empirical coefficient method software

One sample box, one sample cup for testing, and one roll of plastic film for testing

One EU PE # standard sample and one silver calibration standard sample

One set of computer and one printer for the instrument

Product after-sales service

Service Guarantee

1. The entire machine comes with a 24 month warranty and free software upgrades;

2. If the EU adjusts the ROHS testing project, provide free analysis project upgrades;

3. Maintenance response time: Provide technical support by phone within 2 hours of receiving a repair call, and arrive at the user's site within 24 hours if the problem cannot be solved;

4. Regularly follow up with users, with no less than 1 telephone follow-up per month.

5. Any malfunctions (not caused by human factors) that occur during the warranty period will be borne by our company;

If a malfunction occurs after the warranty period (not caused by human factors) and hardware replacement is required, our company will replace the corresponding components at a discounted price.