- Phone
-
Address
Room 417, Building 3, Weiji Technology Park, No. 5 Tian'edang Road, Wuzhong District, Suzhou
Suzhou Liuxinyan Precision Machinery Co., Ltd
Room 417, Building 3, Weiji Technology Park, No. 5 Tian'edang Road, Wuzhong District, Suzhou





RoHS/Coating/Alloy Spectrometer Product Parameters
|
Number |
Product Specifications |
Remarks |
|
Product Specifications |
Product model: BXR-606 | |
|
Product Name:Energy dispersionXFluorescence Spectrometer | ||
|
Analysis principle |
Energy dispersive X-ray fluorescence analysis method | |
|
analyze elements |
-
Analyzable stainless steel、Copper alloys, zinc alloys, tin lead alloys, precious metal analysis, etc.
quantitative testingROHSLead in halogens(Pb)Mercury(Hg)Cadmium(Cd)Chromium(Cr)Polybrominated biphenyls(PBB)And polybrominated diphenyl ethers(PBDE)Total Bromine in,Bromine in halogens(Br)Chlorine(Cl).
Can analyze the most5Layered coating, capable of analyzing up to one element at a time24plant | |
|
working conditions |
Working temperature: 18-22℃ | |
|
Relative humidity: 40% -60% | ||
|
Power supply: AC 220 V±10 %、50/60 Hz | ||
|
Measurement conditions: atmospheric environment | ||
|
technical indicators |
Detection limit: Pb/Cd/Cr/Hg/Br/Cl≦2ppm | |
|
Test sample time: adjustable from 50-300 seconds | ||
|
Test content range: 1ppm-99.99% | ||
|
The dynamic range of analysis and measurement is wide, ranging from 0.005 μ m to 50 μ m | ||
|
Sample shape: any size, any irregular shape | ||
|
Sample type: Plastic/metal/film/powder/Liquid | ||
|
X-ray tube:
Tube voltage/0-50 kVTube current/maximum1~1000 MA,Maximum power: 50 W, filament voltage: 2.0V, filament current: 1.7 A, ray extraction angle: 12 ° Target material: tungsten target, beryllium window thickness: 400um, over temperature overload protection, automatically enters standby mode when not in operation to extend service life. | ||
|
Illumination diameter: collimator 8mm \ \ 2mm \ \ 1mm \ \ 0.5mm | ||
|
Detector:
Amptek Si PIN high-sensitivity detector from the United States, optimal resolution: 149 ± 5eV. | ||
|
AmericaSpellmanhigh-voltage power supply:
Input voltage: DC+24V ± 10%, input current: 4.25A (maximum), output voltage: 0-50KV&1mA, maximum power: 50W, voltage regulation rate: 0.01% (from no-load to full load)
Current regulation rate: 0.01% (from no-load to full load), ripple voltage: Under the premise of outputting rated voltage, the peak value of ripple voltage is 0.25% of the highest output voltage, and the stability after 8 hours is ≤ 0.05%. | ||
|
Cooling system:
There are multiple heat dissipation holes at the front and rear of the body for heat dissipation. There are three fans inside the body for air cooling, and the X-ray tubes are coated with high-temperature heat reducing resin and wrapped in heat dissipation fins. There is also one fan for blowing and dissipating heat. | ||
|
Radiation protection system:
A combination of soft and hard radiation protection design, triple treatment: special radiation treatment for the X-ray tube, double-layer lead skin wrapping for the sample cover, software radiation warning (when personnel accidentally open the sample chamber during instrument operation, the instrument will automatically shut down to ensure operator safety), obtaining the national radiation safety license, and radiation dose below the national standard. | ||
|
Filter: Eight new types of filters with automatic selection settings | ||
|
Sample monitoring system:
30 times15 million pixel colorCCD camera, in the software testing interface, can observe the sample status in real time and adjust the sample position by micro movement before placing the sample for testing. After the sample testing is completed, the pattern is clearly presented in the testing report. | ||
|
Software system:
Quantitative analysis and calculation, using theoretical Alpha coefficient method (NBS-GSC method), integrated FP, and empirical coefficient method, targetingRoHSHalogen-free element(Pb,Cd,Hg,Br,Cr,Cl)Accurate testing. Multi language operation interface, simple operation, one click design, can generate various humanized customized reports, and can automatically output report formats such as PDF, EXCEL, etc. | ||
|
Rated power: 0.35kW | ||
|
Weight: 50Kg | ||
|
Dimensions: 650 (W)×450(D)×450(H)mm | ||
|
Sample cavity size: 350 (W)×300(D)×150 (H) mm, the large sample cover can be opened for testing. | ||
|
Standard Configuration |
Amptek Si PIN detector set: | |
|
A tungsten target special anti radiation treatment side window X-ray tube | ||
|
AmericaSpellmanOne high-voltage power supply | ||
|
Fully enclosed lead plate dual sample chamber | ||
|
A high-precision CCD camera | ||
|
A set of Alpha coefficient method (NBS-GSC method), integrated FP, and empirical coefficient method software | ||
|
One sample box, one sample cup for testing, and one roll of plastic film for testing | ||
|
One EU PE # standard sample and one silver calibration standard sample | ||
|
One set of computer and one printer for the instrument | ||
|
Product after-sales service
Service Guarantee |
1. The entire machine comes with a 24 month warranty and free software upgrades;
2. If the EU adjusts the ROHS testing project, provide free analysis project upgrades;
3. Maintenance response time: Provide technical support by phone within 2 hours of receiving a repair call, and arrive at the user's site within 24 hours if the problem cannot be solved;
4. Regularly follow up with users, with no less than 1 telephone follow-up per month.
5. Any malfunctions (not caused by human factors) that occur during the warranty period will be borne by our company;
If a malfunction occurs after the warranty period (not caused by human factors) and hardware replacement is required, our company will replace the corresponding components at a discounted price. |