Overview

Overview of resin flowmeter: The elliptical gear flowmeter is a lightweight volumetric flow meter with pointer display, word wheel cumulative counting device, and zeroing device. The elliptical gear flowmeter is widely used in liquid flow control in various industrial fields and is suitable for measuring various types of liquids. The CS-LC series elliptical gear flowmeter is a volumetric flowmeter that measures the total flow rate of liquid flowing through pipelines. This instrument has high measurement accuracy, is less affected by liquid viscosity, and does not require a straight pipe section to be installed in front of the meter. It is widely used for cumulative flow measurement of high viscosity media.

Product Details


Resin flowmeter



1Resin flowmetersummary:
Elliptical gear flowmeterA gauge is a lightweight volumetric flow instrument with pointer display, word wheel cumulative counting device, and zeroing device. Elliptical gear flow meters are widely used in liquid flow control in various industrial fields and are suitable for measuring various types of liquids.
The CS-LC series elliptical gear flowmeter is a volumetric flowmeter that measures the total flow rate of liquid flowing through pipelines. This instrument has high measurement accuracy, is less affected by liquid viscosity, and does not require a straight pipe section to be installed in front of the meter. It is widely used for cumulative flow measurement of high viscosity media.

IIResin flowmetermeasuring principle

Under the action of the pressure difference between the liquid at the inlet and outlet of the diesel flowmeter measurement chamber, a pair of elliptical gears continuously rotate on the bearings and discharge the liquid. By measuring the number of revolutions of the elliptical gears, the total value of the liquid flowing through the instrument can be determined. If the volume Q discharged after one revolution of the elliptical gear and the number of rotations of the elliptical gear per unit time is N, then the volume of liquid flowing through during that time is NQ.

IIIResin flowmeterProduct Features

The elliptical gear flowmeter installed correctly according to the requirements can ensure sufficient accuracy during use, and the accuracy of the cumulative value can usually reach level 0.5, making it a relatively accurate flow measuring instrument. However, if the flow rate of the measured medium is too high during use.

Small, the impact of instrument leakage errors will become prominent, and sufficient measurement accuracy cannot be guaranteed. Therefore, different models and specifications of diesel flow meters have an allowable value for the minimum flow rate, and the measurement accuracy can only be guaranteed when the actual measured flow rate is greater than the lower limit flow rate allowable value.Attention should be paid to the temperature of the measured medium in heavy oil flow meters, otherwise it will not only increase measurement errors, but also have the possibility of gear jamming. Therefore, heavy oil flow meters are used within the temperature range specified by the instrument.

4、 Resin flowmeterperformance parameter

Flow meter connection method:Flange connection:DN10DN200

Accuracy level of flowmeter:Common0.5Grade, high precision0.2Grade

Flow meter pressure resistance:Common1.6MPa,High pressure3.2MPa

Temperature resistance of flowmeter:Ordinary type<120℃, high pressure type <200

Material of flowmeter production:Cast iron, cast steel, stainless steel, etc

rotatable parts:Aluminum alloy, stainless steel, etc

Optional oil filter can be installed

The elliptical gear flowmeter should be cleaned before installation. If the liquid contains solid particles, a filter must be installed upstream of the pipeline; Heavy oil flowmeterThere are no specific requirements for the front and rear straight pipe sections. It can be installed horizontally or vertically. During installation, the elliptical gear rotation axis of the flowmeter should be parallel to the ground

Flow measurement is independent of the flow state of the fluid, as the elliptical gear flowmeter relies on the pressure head of the measured medium to drive the elliptical gear to rotate for measurement.

The higher the viscosity of the medium, the smaller the amount of leakage from the gear and measuring space gap. Therefore, the larger the viscosity of the measured medium, the smaller the leakage error, and the more advantageous it is for measurement.

The elliptical gear flowmeter has high measurement accuracy and is suitable for measuring the flow rate of high viscosity media, but it is not suitable for fluids containing solid particles (solid particles can jam the gear, making it impossible to measure the flow rate). If gas is mixed in the measured liquid medium, it can also cause measurement errors.

Header display:

Pointer accumulation, zero return, pulse output4-20mAOutput, LCD display, communication output

Instrument model:

LC-11Display12Display signal13Signal outputHReturn to zeroNHigh viscosityTHigh temperatureYliquid crystal display

Measurement medium:

Liquids and various oils

Caliber specification:

10---200

Flow measurement range:

0.04-340 m3/h

Measurement accuracy:

0.5level 0.2level

Temperature of the tested medium:

-20-100 , Zui High+200

working pressure:

1.6MPa 2.5MPa 6.4MPa

Output signal:

Pulse4--20mARS485

Communication type:

RS485

Power Supply:

DC12V ---DC24V

Installation method:

Flange connection, threaded connection

Explosion proof grade:

ExiaIIBT4

Protection level:

IP65

5、 Resin flowmeterMeasurement range and work pressure

model

CS-LC-Acast iron

CS-LC-Ecast steel

CS-LC-Bstainless steel

nominal pressure

Mpa

1.0 1.6

2.5 4.0 6.4

1.0 1.6

Viscosity of the tested liquid

2 200 mPa.s

Temperature of the tested liquid

-20℃~+100

flow measure Fan enclosem³h

model

accuracy class

CS-LC-Acast iron

CS-LC-Ecast steel

CS-LC-Bstainless steel

Nominal caliber(DNmm

0.5

0.2

0.5

0.2

0.5

0.2

10

0.040.4

0.10.4

0.040.4

0.10.4

0.10.5

0.10.5

15

0.251.5

0.31.5

0.251.5

0.31.5

0.31.5

0.31.5

20

0.53

0.63

0.53

0.63

0.63

0.63

25

16

1.26

16

1.26

1.26

1.26

40

2.515

315

2.515

315

315

315

50

424

4.824

424

4.824

4.824

4.824

65

540

840

540

840

840

840

80

1060

1260

1060

1260

1260

1260

100

16100

20100

16100

20100

20100

20100

150

32190

38190

32190

38190

38190

38190

200

34340

68340

34340

68340

68340

68340

6、 Resin flowmeterSelection code

Changshun Company Business Logo

Basic model

LC

Basic models of elliptical gear flowmeter

Caliber selection

-□□

Diameter size

Material selection

-A

cast iron

-E

cast steel

-B

stainless steel

output signal

-2

No signal output

-3

pulseDV24Vpower supply

-4

420mA DV24Vpower supply

Zeroing function

-N

No reset function

-F

Zeroing function

filter

-N

No Filter

-G

Including filter

Traffic selection

(□~□)

Flow range